Product catalog summary
Specifications:
The document outlines various cooling solutions for data centers, focusing on the Cooling Distribution Unit (CDU) and its components. The CDU provides cooling water for up to six rear door heat exchangers with capacities ranging from 342,000 Btu/hr (100kW) to 512,000 Btu/hr (150kW), featuring full run/standby capability (N+1). It includes an internal manifold with leak-free quick-release couplings for easy installation and connection.

CDU Unit:
A dedicated cabinet houses up to six CDU Modules, facilitating initial installation and future upgrades. It includes power distribution and chilled water connectivity, with alarms and environmental data managed centrally.

Modular CDU System:
The 68,000 Btu/hr (20kW) CDU Module is a rack-mountable unit providing controlled cooling water to one or two rear door heat exchangers. It features dew point temperature control, auto fill and bleed of coolant, and full alarm monitoring.

Server Cabinets & Rear Door Heat Exchangers (RDHx):
These components are designed for high heat density environments, removing up to 102,000 Btu/hr (30kW) of heat at the source and rejecting it to water. They feature condense-free operation and are easily installed with quick-release couplings.

Chillers:
Energy-efficient chillers with capacities up to 2,049,000 Btu/hr (600kW) are available, offering full run/standby capability and optional free cooling.

DRU (CRAC) Unit:
Designed for high-density load areas, these units offer cooling capacities from 273,000 Btu/hr (80kW) to 410,000 Btu/hr (120kW) and are available in various configurations, including chilled water and DX.

IPAC (CRAC) Unit:
Floor-standing units available in chilled water or DX configurations, with cooling capacities from 51,000 to 273,000 Btu/hr (15-80kW). They offer upflow or downflow air patterns and include options for humidity control.

Service & Maintenance:
A national network of engineers supports all HVAC equipment types, ensuring optimal operating efficiency.

Central Station Air Handlers & FANWALL TECHNOLOGY®:
Custom-designed air handlers provide up to 200,000+ cfm, with FANWALL TECHNOLOGY® offering compact, energy-efficient air movement solutions.

Research and Development:
Huntair emphasizes innovation through active R&D, focusing on integrated airflow solutions based on customer needs.
See more

Catalog excerpts

HD Rack Cooling-1

® SERVER COOL Blade Server & Data Room Cooling, CRAC units, Installation and Service

 Open the catalog to page 1
HD Rack Cooling-2

CDU (Cooling Distribution Unit) 1 provides cooling water for up to 6 rear door heat exchangers. | with full run/standby manifold with leak free quick release couplings for connection to the rear door (22mm) hose sets. Chilled point temperature control of cooling water, internal CW filtration. Auto fill and bleed of coolant. Full alarm monitoring A dedicated cabinet to house enable initial install to be perfect upgrade path. The cabinet houses power then be simply plugged in | as the data centre expands or heat loads increase. Alarms, humidity data are managed through the central power distribution...

 Open the catalog to page 2
HD Rack Cooling-3

Server Cabinets IPAC (CRAC) Unit Rear Door Heat Exchangers Server Cabinets & Rear Door Heat Exchangers (RDHx) have powerful cooling capacities, heat removed at source and room. Condense free operation using dew point controlled water from the variable speed. 80% front full range of accessories. Easily nstalled via leak free quick conditioning units are designed for high density load areas where a large cooling duty is required, from a compact application of data centre cooling capacities Available in chilled water, DX, DX with water cooled condenser and glycol free cooling configurations A full...

 Open the catalog to page 3
HD Rack Cooling-4

Group Products & Services Server Cabinets & Rear Door Heat Exchangers (RDHx) Server Cabinets and Rear Door Heat Exchangers (RDHx) are designed to provide an environment for high heat density servers and IT source rejecting it to water rather CDU (Cooling Distribution Unit) cooling water, close controlled and above dew point for up to 6 rear door heat exchangers. It is capable cooling capacity. CDU Module is a self contained provide cooling water above dew point to 1 or 2 rear door heat exchangers and is designed to slide in a standard 19" rack (6u high) For greatest flexibility and perfect upgrade...

 Open the catalog to page 4