1. Catalogs
  2. Huons Medicare
  3. HUEN IVH ER (Room Sterilization)

HUEN IVH ER (Room Sterilization)

HUEN IVH ER (Room Sterilization)

HUEN IVH ER (Room Sterilization)

Product catalog summary
Introduction to Bio-decontamination
This document discusses the technology of room bio-decontamination using vaporized hydrogen peroxide (H2O2), which sterilizes both air and surfaces in enclosed spaces. This method is crucial for maintaining sterile environments in various facilities, including GMP laboratories, hospitals, and biosafety level facilities.

Sanitization and Sterilization Levels
- Sanitization: Achieves a two log reduction (10^-2).
- Disinfection: Achieves a four log reduction (10^-4).
- Sterilization: Achieves a six log reduction (10^-6), ensuring 99.9999% microbial death.

Configuration and Technology
The system includes a sterilizer, air circulators, and scrubbers. The technology is eco-friendly, decomposing H2O2 into water and oxygen without leaving residues. It uses a 35% hydrogen peroxide solution, minimizing condensation and corrosiveness through nano-sized spraying.

Applications and Recommended Intervals
- Pharmaceutical companies: Sterilization every 3 months.
- Hospitals: Sterilization every 3 months.
- Food companies: Weekly sterilization.
- Ambulances: Sterilization after transporting infectious patients.

Features of HUEN IVH ER
The HUEN IVH ER model uses air cushion technology for efficient sterilization and dispersant diffusion. It is compact, easy to move, and operates with high sterilization efficiency. The system includes a biological indicator for sterilization verification and a gas detector for H2O2 measurement.

Sterilization Service Process
1. Field Investigation: Assess site conditions and establish a sterilization plan.
2. Sterilization Plan: Develop a site-specific plan.
3. Perform Sterilization: Install indicators, spray disinfectant, and remove sterilant.
4. Sterilization Verification: Culture biological indicators for 7 days.
5. Sterilization Report: Issue a report confirming sterilization.

Conclusion
The document highlights the effectiveness and necessity of vaporized hydrogen peroxide sterilization in maintaining sterile environments across various sectors. The HUEN IVH ER system offers a reliable and efficient solution for space sterilization.
See more

Catalog excerpts

HUEN IVH ER (Room Sterilization)-1

Room Bio-decontaminator Room Bio-decontamination With Invisible Vaporized Hydrogen Peroxide

 Open the catalog to page 1
HUEN IVH ER (Room Sterilization)-2

Bio-decontamination Room sterilization • his is a technology that sterilizes both the air and the surface in a closed space. It is a method of T disinfecting by spraying a sterilant into the room. • he disinfectant must be evenly distributed in the space for proper disinfection. T Configuration Scrubber 1 Why is sterilization necessary? Laboratory and production rooms of GMP facilities (pharmaceutical companies, etc.), animal testing centers, and biosafety BSL-3 level facilities require clean and sterile management. In addition, hospital facilities dealing with pathogenic bacteria require sterilization...

 Open the catalog to page 2
HUEN IVH ER (Room Sterilization)-3

Hydrogen peroxide is a safe substance. Hydrogen peroxide fumigation sterilization is safe and eco-friendly because it naturally decomposes into water and oxygen at the same time as 6 log reduction (99.9999% death) and no residue remains. Recommended interval for space sterilization Pharmaceutical company Hospital (operation room, etc.) Food company 3 months, sterilization is affected, such as bringing in equipment Conducted weekly, at all times After transfer of infectious patient (tuberculosis patient) Purpose and place of use Space sterilization is essential in various fields, from hospitals...

 Open the catalog to page 3
HUEN IVH ER (Room Sterilization)-4

Air Cushion technology applied Hydrogen peroxide steam generation technology for space sterilization Developing a new technology to micronize liquid sterilants under high temperature and high pressure and evaporate them with hot air. A small chamber efficiently evaporates a large amount of sterilant. Using an efficient chamber, the diffusion of hydrogen peroxide sterilant is excellent, and there is no residual sterilizing agent inside, so it is durable. Temperature boundary layer High pressure air Nozzle Hydrogen peroxide sterilant Features of HUEN IVH ER - 6 log reduction (99.9999% kill) - Effective...

 Open the catalog to page 4
HUEN IVH ER (Room Sterilization)-5

Product specification Model name Disinfection room size Exclusive disinfectant Equipment to increase disinfection efficiency by spreading the sprayed sterilant evenly inside the rooms Equipment that decomposes the sprayed sterilant into water and oxygen (decomposition catalyst device) ’s exclusive sterilant for effective sterilization BIOLOGICAL INDICATOR Biological indicator that can confirm whether sterilization has been performed properly Gas detector to detect and measure H2O2

 Open the catalog to page 5
HUEN IVH ER (Room Sterilization)-6

Sterilization service process 01 Field investigation Sterilization plan Perform sterilization Sterilization verification Sterilization report • ontrast drawings and C field measurements • Air conditioning status check • Check flooring and wall materials • stablish a E sterilization plan suitable for the site • I/CI installation, B sealing • Disinfectant spraying (spreading disinfectant and waiting) • emoval of sterilant R • ssuance of I sterilization report 3-Step sterilization process of HUEN IVH ER Sterilization service The service price reconnaissance system provides a reasonable cost. Excellent...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.