HBM-1
1 / 8Pages

Catalog excerpts

HBM-1 - 1

Combining Biometry and Topography for Greater Accuracy Optical Biometry with Full Corneal Topography System

Open the catalog to page 1
HBM-1 - 2

Superior Optical Biometer ‘HBM-1’ The HBM-1 is completely integrated with Biometry and Topography allowing the user to calculate IOL power in cataract surgery patients. A variety of formulas, DCM (Dense Cataract Mode) and Placido disc analytics technologies provide more reliable results, while measuring 10 clinical parameters faster and more accurately. The HBM-1 is the perfect combination for cataract surgery

Open the catalog to page 2
HBM-1 - 3

Biometry Measurement Topography Measurement Myopia Management Optimal Workflow for Cataract Surgery Achieve the ultimate workflow for cataract surgery with the simultaneous measurement of 10 optical biometry and full corneal topography values. The correct calculation of the Intraocular Lens (IOL) Power leverages a variety of formulas, enhancing the efficiency and precision of cataract surgery planning. Reliable Measurement Data & Value The HBM -1 provides biometry and topography values, consistently delivering reliable data even in cases with lens opacity in cataract patients . Featuring...

Open the catalog to page 3
HBM-1 - 4

Optimized workflow for Cataract surgery All 10 examinations at once IOL Power value with the various Formula 10 types of data for IOL Power calculation ; All accurate result values are based on the NO.6th AL, NO.8th ANT measurement data Standard De viation(STD). Fast measurement speed minimizes patient discomfort. The measured result value suggests the IOL Power value after calculation through the various Formulas & IOL. 10 methods data measurement : Axial Length(AL), Anterior Chamber Depth(ACD), Central Corneal Thickness(CCT), Lens Thickness(LT), Keratometry, Topography, Keratoconus,...

Open the catalog to page 4
HBM-1 - 5

The HBM-1 provides reliable data and cornea information to provide an accurate IOL Power calculation. Measuring the highly reliable Biometry value of a Cataract patient Accurately assess the critical biometry values in cataract patients, leveraging Verified Light Inter ference Technology. This technology ensures the acquisition of reliable data, undeterred by the varying capabilities of individual users. Precise Corneal Information and K Values The HBM-1 provides accurate analysis and measurement data regarding the overall Cornea Axial, Tangential, Refractive Power, Elevation Map. Data...

Open the catalog to page 5
HBM-1 - 6

Wide management ‘Monitoring, regular care’ by HBM-1 Myopia management functions for Integrated management HBM-1 can monitor the entire history of the periodical and provide a graph of the AL and refractive variation. The data of REF(RX) transmitted by Huvitz RK series can be utilized as the basis of diagnosis. Th e H B M -1 c a n ta ke th e p ati e nt th ro u gh th e ir Ortho-K Lenses prescription and surgery, providing a comparison of the variation before and after wearing the Ortho-K Lenses. It can also observe anisometropia which can be presented and reviewed with the patient. Check the...

Open the catalog to page 6
HBM-1 - 7

User-centric environment Easy to link for diverse devices by convenience connectivity The report for evaluation, the diagnosis provided The standard format easily connects each product to DICOM, and the measured data can show on a PC through the Huvitz HIIS-1 software. The HBM-1 provides the systematic report based on the IOL Power values in Biometry, Topography and IOL. Network in Huvitz Integrated Image Server(HIIS-1) Report : Biometry, Topography, IOL Informing the beginning and end by Image and Sound Guidance. Detecting the micro movement. Auto Tracking with reduced error A sound alarm...

Open the catalog to page 7
HBM-1 - 8

Optical Biometry with Full Corneal Topography System Specifications Biometry Parameter Measuring range Axial length Anterior chamber depth Central corneal thickness Crystalline lens thickness White-to-white distance Pupil diameter Measuring range Corneal curvature radius Cornea refractive power 25.96 D–67.50 D (Cornea equivalence's refractive index : 1.3375) Direction of principal meridians Measuring range : 1°–180° Accuracy : according to the ISO 10343 : 2014 Corneal Topography Working distance Placido disc Points Analyzed Over 100,000 (Measured points : Over 6,220) Measuring accuracy...

Open the catalog to page 8

All Huvitz catalogs and technical brochures

  1. HPE-410

    6 Pages

  2. HPE-810

    4 Pages

  3. HNT-1/1P

    4 Pages

  4. HOCT-1/1F

    12 Pages

  5. HRT-7000

    2 Pages

  6. CIT

    2 Pages

  7. HCP-7000

    1 Pages

Archived catalogs

  1. HDC-900N

    2 Pages

  2. HRK-9000A

    4 Pages

  3. HRM-300 Series

    10 Pages

  4. HIS-5000U

    2 Pages

  5. HBK-7000

    2 Pages

  6. HS-7000

    1 Pages

  7. HS-5000

    2 Pages

  8. HNT-7000

    2 Pages

  9. HT-5000

    2 Pages

  10. EXCELON

    2 Pages

  11. CAB-4000

    2 Pages

  12. CLM-3100P

    2 Pages

  13. HLM - 7000

    2 Pages

  14. CDC-4000

    2 Pages

  15. HCD-7000

    2 Pages

  16. CCP-3100

    2 Pages

  17. HRT-7000

    2 Pages

  18. HDR-7000

    2 Pages

  19. HRK-7000A

    2 Pages

  20. HRK-8000A

    2 Pages