The document introduces the Huvitz Tonometer HNT-1/1P, highlighting its innovative features that combine value and performance. It emphasizes the Smart Puffing Control technology designed for patient comfort and accurate intraocular pressure (IOP) measurement.

Specifications
  • Intraocular Pressure Measurement: Modes include AT3D, AT2D, and Manual with a range of 0-60mmHg and accuracy of ±5mmHg.
  • Smart Puffing Control (SPC): Offers SPC30 and SPC60 modes for customized puffing intensity.
  • Central Cornea Thickness (CCT) Compensation: Available with pachymetry measurement mode and accuracy of ±5μm.
  • Common Features: Non-contact type, 11mm working distance, 7-inch TFT LCD screen, thermal line printer, and power-saving sleep mode.

Key Features
  • Smart Puffing Control: Automatically adjusts puffing pressure based on the patient's IOP, enhancing comfort by stopping air pressure delivery once the correct signal is acquired.
  • Auto Tracking and User Interface: Features automatic 3D tracking and a user-friendly interface with animated feedback for easy operation.
  • CCT Measurement and IOP Compensation: Allows input of corneal thickness for accurate IOP compensation, with built-in pachymeter in HNT-1P.
  • ACA Measurement: Captures anterior chamber angle cross-sections to aid in diagnosing angle-closure glaucoma.
  • High-Resolution Touch Screen: 7-inch color TFT LCD for vivid, real-time imaging.
  • Safety and Convenience: Includes a safety stopper function, motorized chin rest, high-speed internal printer, and network data transfer capability.

Conclusion
The Huvitz Tonometer HNT-1/1P sets a new standard in IOP measurement with its advanced features, ensuring accurate, comfortable, and efficient patient assessments.
See more

Catalog excerpts

HNT-1/1P-1

Specification Intraocular Pressure Intraocular Pressure Measurement Mode [ AT3D(X, Y, Z), AT2D(X, Y), MT(Manual) ] Measurable Range Measurement Mode Measurement Value Measurement Accuracy Smart Puffing Control(SPC) Feature Central Cornea Thickness Compensation Function Central Cornea Thickness Measurement (HNT-1P only) Pachymetry Measurement Mode [ AT3D(X, Y, Z), AT2D(X, Y), MT(Manual) ] Measurable Range Measurement Value Measurement Accuracy Working Distance Data Display Thermal Line Printer Power saving Function(Sleep Mode) Electrical Power Dimension & Weight Designs and details can be changed without prior notice for the purposes of improvement. HUVITZ Co., Ltd. 38, Burim-ro 170beon-gil, Dongan-gu, Anyang-si, Gyeonggi-do, 14055, Republic of Korea Tel:+82-31-442-8868 Fax:+82-31-477-8617 http://www.huvitz.com M2ARAA-16-00001(Rev.C) Huvitz Tonometer with Smart Puffing Control Tech Huvitz Tonometer with Smart Puffing Control Tech Newly designed, Huvitz continues to lead in product development combining innovation with value and performan

 Open the catalog to page 1
HNT-1/1P-2

Smoothness and Perfection HNT-1/1P Soft & Smart Puffing, Corneal Thickness Compensation, Combined with Great Economical Value - A New Standard in Intraocular Pressure Measurement The new tonometer HNT-1/1P measures customized intraocular pressure with smart function autoadjustable puffing intensity. Intuitive interface based on corneal thickness to compensate for IOP value, produces accurate measuring data immediately and effortlessly.

 Open the catalog to page 2
HNT-1/1P-3

Soft and Smart Puffing with Your Patient's Comfort in Mind. Pressure Curve Variation by SPC 30 Intraocular Pressure Concept image visualized Smart Puffing Control. Auto-adjustable Smart Puffing Control for Intraocular Pressure Its smart function is possible with customized intraocular pressure as it adjusts the puffing pressure level based on the patient's own intraocular pressure. The moment the proper intraocular pressure signal is acquired, air pressure delivery stops, reducing the discomfort caused to the patient by unilateral high-pressure puffing. Auto Tracking Guide Display Automatic 3D...

 Open the catalog to page 3
HNT-1/1P-4

IOP Measurement Taking into Accurate Corneal Thickness Compensation Account Corneal Thickness - To measure accurate intraocular pressure, Producing Comprehensive Data HNT-1 to print-out compensated IOP value. simply input patient's corneal thickness on the (HNT-1) When using the built-in pachymeter, available High Resolution 7''Color Touch-Screen By adopting a wide color TFT LCD, it produces a vivid, high resolution (with no afterimage) image with real-time processing chip. CCT(Central Cornea Thickness) Measurement User-friendly and easy to use touch-screen. Enables accurate measuring corneal...

 Open the catalog to page 4

All Huvitz catalogs and technical brochures

  1. HBM-1

    8  Pages

  2. HPE-410

    6  Pages

  3. HPE-810

    4  Pages

  4. HOCT-1/1F

    12  Pages

  5. HRT-7000

    2  Pages

  6. CIT

    2  Pages

  7. HCP-7000

    1  Page

Archived catalogs

  1. HDC-900N

    2  Pages

  2. HRK-9000A

    4  Pages

  3. HRM-300 Series

    10  Pages

  4. HIS-5000U

    2  Pages

  5. HBK-7000

    2  Pages

  6. HS-7000

    1  Page

  7. HS-5000

    2  Pages

  8. HNT-7000

    2  Pages

  9. HT-5000

    2  Pages

  10. EXCELON

    2  Pages

  11. EXCELON XD/XQ

    8  Pages

  12. CAB-4000

    2  Pages

  13. CLM-3100P

    2  Pages

  14. HLM - 7000

    2  Pages

  15. CDC-4000

    2  Pages

  16. HCD-7000

    2  Pages

  17. CCP-3100

    2  Pages

  18. HRT-7000

    2  Pages

  19. HDR-7000

    2  Pages

  20. HRK-7000A

    2  Pages

  21. HRK-8000A

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.