HRK-7000 HRK-7000A HRK-7000 / HRK-7000A with WAVEFRONT TECHNOLOGY HRK-7000 / HRK-7000A Auto Ref-Keratometer Image showing the Huvitz HRK-7000 connected to an external monitor(optional) SPECIFICATION MEASUREMENT MODE K/R Mode KERATOMETRY Continuous Keratometry & Refractometry REF Mode Refractometry KER Mode Keratometry CLBC Mode Contact Lens Base Curve Measurement KER P Mode Peripheral Keratometry Radius of Curvature 5~10.2mm ( Increments : 0.01mm ) 33.00~67.50D ( When corneal equivalent refractive index is 1.3375 ) ( Increments : 0.05/0.12/0.25D) Corneal Astigmatism 0.00~ -15.00D ( Increments : 0.05/0/12.0/25D) Axis REFRACTOMETRY Corneal Power 1~180 ( Increments : 1 ) Vertex Distanc ( VD ) 0.0, 12.0, 13.5, 15.0 Pupil, Iris Diameter 2.0~14.0mm ( Increments : 0.1mm ) Sphere( SPH ) -25.00~+22.00 ( When VD=12mm ) ( Increments:0.12 and 0.25D ) Memory of Data 10 measurements for each eye Cylinder ( CYL ) 0.00~10.00D ( Increments:0.12 and 0.25D) OTHERS CLBC Mode 1~180 ( Increments :1 ) Internal Printer Thermal Line Printer Cylinder Form -, +, Power Saving Automatic switch-off ( 5min ) Pupil Distance 10~85mm Display 6.5 inch Color TFT LCD Power Supply AC100-240V, 50/60Hz ( Free Voltage ) 60W Dimension 252 ( W ) x 500 ( D ) x 432 ( H ) mm / 20kg Minimum Pupil Diameter 2.0mm HRK-7000A MOVEMENT RANGE Up-Down The correct pass for measurement of human eyes led by the new technology - HUVITZ HRK-7000 / HRK-7000A Unlike many conventional diagnostic devices, HRK-7000 / HRK-7000A is based on Hartmann-Shack wavefront sensor, which analyzes many focal spots of a light wavefront. It has the ability to measure not just the basic refraction error of a customer, but to obtain a spatially resolved refraction map of the wavefront. 15mm Left-Right 5mm 2mm Forward-Backward 5mm 2mm Huvitz Building 689-3, Geumjeong-dong Gunpo-si, Gyeonggi-do, 435-862, Korea Tel : + 82-31-442-8868 Fax : + 82 -31-477-8617 http : // www.huvitz.com Distributed by
Open the catalog to page 1To measure a human eye with ultra-precision, Huvitz’s Wavefront Technology can be the right answer. Human eye is unique as a fingerprint and requires a custom corrective solution. For this reason, we need fast, versatile and accurate methodologies for eye examination according to each individual customer's unique vision correction needs. HUVITZ HRK-7000 / HRK-7000A based on WAVEFRONT technology has opened up new possibilities for diagnosis of ocular error. HRK-7000 / HRK-7000A with WAVEFRONT TECHNOLOGY Optimized Optical System Retro-Illumination Mode 6.5" Color TFT LCD HRK-7000A (Auto Tracking...
Open the catalog to page 22 Pages
4 Pages
2 Pages
8 Pages
10 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages