X-ray film viewer-1

Specification and Technology Parameter PD-OB1-E LED High luminance illuminatorPatent No. 20092005163613 Viewing area(WxH mm) Power Consumption 360x440 • Automatic switch(Film Sensor) The viewing area will be bright when insert the film and it will be black out when extract the film out. • Adopt with the import Acrylic euphotic panel, high finish degree, uniformity and soft light. Long life for use and not easy to be transmutation and yellow discolouration. Adopt with LED backlight technology. There is no dark area in the viewing area. The uniformity of the viewing screen is more than 90%. Take the lead in satisfying the standard of mandatory luminance, evenness, stability, color temperature etc of China X-Ray illuminator YY/T0610-2007 within the same kinds of products in china. Backlight type, color temperature, life Power Supply Luminance and adjusting area Luminance Uniformity Clipping Device High luminance LED. 10.000K / 6.500K. 100,000 hours AC 90V-240V, 50/60HZ Built-In electrical source Average luminance 300 cd/m2-5,000 cd/m2 / average Columniform catercorner compaction clipping device Install way Suitable Film Use Condition Wall mounting, standing (the stand is the spare parts for choice, have to pay for it separate) Normal Simulation X-Ray Film, High Density Digital X-Ray Film, Molybdenum Target Mammography Film Illuminance of the viewing rooms should less than 100 lux • Advanced columniform catercorner compaction clipping device. It is easy for insertion, firm for clipping, easy for extraction. *The picture just for your reference, the products are subject to the real object. • Adopt with the global voltage 90V-240V Built-In electrical source. Leading technology, save space. ® Luminance adjusting for large-scale(300-5,000cd/m2). It meets the viewing and diagnostic requirement for different density film of simulation digital and mammography adequately. • Nobler thin design The three-dimensional design frame use silver and dark gray, and the new-style material such as electrophoresis aluminum-alloy, plastic alloy etc. It shows the nobler character. The shape is thin, the thinness is only 4cm. • The highest average luminance for the latest illuminator is more than 5,000 cd/m2(average illuminance 16,000 lux). This new type of patent product adopt with the international advance technology high luminance LED as the backlight. Compare with the former CCFL for LCD product, the highest average luminance increase from 1200 cd/m2 to over 5,000 cd/m2(~16,000 lux) it could be used for viewing and diagnosis high density digital film and mammography film. The life of LED is 100,000 hours. It is over 5 times than the CCFL lamp. • 10.000K white and light-blue light color temperature is more suitable for viewing and diagnosis film than the 6500K white light. Colour Temperature

 Open the catalog to page 1
X-ray film viewer-2

Specification and Technology Parameter A: fixed luminance, B1: luminance adjusting, B3: Digital Button-Press luminance adjusting S: Single panel independent film automatic sensor PD-T Series LED High luminance illuminator Spec. Backlight type, color temperature, life Power Supply Clipping Device Feature High luminance LED. 10.000K. 100,000 hours AC 90V-240V, 50/60HZ Built-In electrical source Columniform catercorner compaction clipping device Wall-mounting, standing (the stand is the spare parts for choice, have to pay for it separate) Illuminance of the viewing rooms should less than 100 lux...

 Open the catalog to page 2
X-ray film viewer-3

minance Illuminator (Aluminum uminance illuminator Feature • The uniformity of the viewing screen is more than 70%, stability is less than 2%, color temperature is more than 6500K, it satisfies with the latest national industry standard. Feature The only one adopt the high intensity aluminum of shape wholly technology, beautiful and firm. • The average luminance of viewing screen increase from 1200cd/m2 to over 2000cd/m2, the uniformity is over 70%, higher and more uniformity luminance shows the ample imaging hiberarchy, and provide more diagnostic information for doctors. • High intensity aluminum-alloy...

 Open the catalog to page 3
X-ray film viewer-4

minance Illuminator PD-GA Frame Design Fixed Luminance Luminance Adjusting Digital Button-Press Luminance Adjusting Adopt with the leading technology LED light source There is no dark area in the viewing area, the viewing screen uniformity is more than 90% White and light-blue color temperature 10.000K white and light-blue color temperature is suitable for viewing and diagnosis x-ray film Acrylic viewing screen High finish degree. Uniformity and soft light. Long life for using and not easy to be transmutation and yellow discoloration. PD-F Series Super thin High luminance illuminator • Super...

 Open the catalog to page 4