Product catalog summary
Product Description
The Mafund plate is available in two types, both with a hardness of 45 Sh. The solid Mafund plate (MF15) is 15mm thick, made from natural rubber, and supports high loads up to 54 kg/cm2. The hollow Mafund plate (MF25) is 25mm thick, made from SBR rubber, and supports loads up to 5 kg/cm2 with high deflection.

Applications
Mafund plates are used for vibration insulation in large machinery and buildings, particularly under concrete bases or between concrete layers.

Specifications
The required panel area is determined by the load. The MF25 plate (50 x 25 cm) supports a static load of 5 kg/cm2 with a deflection of 2.7 mm. Higher deflection can be achieved by layering panels, such as using two MF25 layers to form an MF50.

Dimensions
MF15: 500 x 250 x 15mm (solid)
MF25: 500 x 250 x 25mm (hollow)
MF50: 500 x 250 x 50mm (hollow)

Performance Data
Graphs indicate deflection and static load relationships, as well as frequency responses for different panel sizes and configurations.
See more

Catalog excerpts

Rubber Pads - MF-1

Vikas Mafund Pads Product Description The Mafund plate is manufactured in two types with the same hardness of 45 Sh. The solid Mafund plate is 15mm thick (MF15) and is best used where there is a very high load of up to 54 kg/cm2 and is made from natural rubber. The hollow Mafund plate 25mm thick (MF25) gives a relatively high deflection. The plate can hold a load of up to 5 kg/cm2 and is made of SBR rubber. Applications The Mafund plate is used for the vibration insulation of larger and heavy machinery, typically under a concrete base. The plates can also be used in buildings for noise and vibration insulation between layers of concrete. It is possible with both types of panel to obtain higher degrees of deflection by layering panels on top of each other. For example look at curves for MF50, which are 2 layers of MF25. MF15: 500 x 250 x 15mm (Mafund solid) MF25: 500 x 250 x 25mm (Mafund hollow) MF50: 500 x 250 x 50mm (Mafund hollow) The area of panels required is determined by the load. The normal static load distribution for a hole MF25 plate (50 x 25 cm) is 5 kg/cm2, which gives a deflection of 2.7 mm. Frequency / Static Load Frequency / Static Load MF25 Deflection, Static Load Deflection, Static Load Frequency / Static Load Web: www.iac-acoustics.com Email: [email protected] Shop: View our online shop for AVMs Errors and Omissions Excepted (E&OE). Deflection, Stati

 Open the catalog to page 1

All Iac Acoustics catalogs and technical brochures

  1. Radio 24-7

    2  Pages

  2. NBC Universal

    2  Pages

  3. IMG Studios

    2  Pages

  4. Dolby

    2  Pages

  5. BBC Mailbox

    4  Pages

Archived catalogs

Related Searches
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.