video corpo

ProFound AI™ for 2D Mammography and Tomosynthesis
2Pages

{{requestButtons}}

Catalog excerpts

ProFound AI™ for 2D Mammography and Tomosynthesis - 1

ProFound AI ™ for 2D Mammography and Tomosynthesis Precise, Powerful & Proven Technology iCAD, the market leader in multi-vendor computer-aided detection of breast cancer with more than 4,000 installations worldwide, introduces the latest in artificial intelligence – ProFound AI. ProFound AI is a precise, powerful and proven deep learning, artificial intelligence platform that assists radiologists with reading 2D mammography and breast tomosynthesis. A new era in breast AI is here! Challenge Mammography reading can be complicated, especially in dense breasts. Tomosynthesis reading can be time consuming and radiologists are confronted by workload issues to read extensive amounts of data while maintaining high accuracy for detecting malignancies. As incidence rates of breast cancer continue to rise, it is increasingly important to improve cancer detection while reducing unnecessary recalls resulting from false positives. Solution Designed for radiologists, ProFound AI™ for 2D Mammography* and ProFound AI™ for Tomosynthesis is revolutionizing reading paradigms and provides a transformative solution to address these challenges. The high-performing cancer detection and workflow solution rapidly and accurately analyzes each image, detecting both malignant soft tissue densities and calcifications with unrivaled accuracy. ProFound AI for Tomosynthesis is proven to assist radiologists in addressing the challenges of reading cases by improving cancer detection rates, while simultaneously reducing false positives and unnecessary patient recalls. Workflow Benefits Clinical Performance Benefits Based on FDA reader study results, ProFound AI for tomosynthesis offers radiologists: • AI algorithm with superior performance for the detection of breast cancer and high specificity with low numbers of false positives • Certainty of Findings and Case Scores to assist in clinical decision-making and prioritizing caseloads • Workflow solution that renders quick results while analyzing each image for detections • Deep Learning technology allows for continuously improved algorithm performance via updates • 8.0% average increase in sensitivity • 6.9% average increase in specificity • 7.2% average reduction in recalls • 5.7% average improvement in radiologists AUC • 52.7% reduction in reading time *ProFound AI for 2D Mammography is CE Mark Approved. It is not available for sale in the U.S. ProFound AI for Tomosynthesis is FDA Cleared, CE Marked and Health Canada Licensed. Breast Health Solutions 1.866.280.2239 toll free | 1.603.882.5200 | sales@icadmed.com | www.i

Open the catalog to page 1
ProFound AI™ for 2D Mammography and Tomosynthesis - 2

Certainty of Finding and Case Scores The ProFound AI algorithm is trained to detect malignant soft tissue densities and calcifications for both mammography and tomosynthesis. Certainty of Finding and Case Scores are assigned to each detection and each case respectively. Certainty of Finding and Case Scores are relative scores computed by the ProFound AI algorithm and represent the algorithm’s confidence that a detection or case is malignant. The scores are represented on a 0% to 100% scale. A higher score indicates a higher level of confidence in the malignancy of the detection or case. The...

Open the catalog to page 2

All ICAD catalogs and technical brochures

  1. VeraLook®

    2 Pages

  2. SecondLook®

    1 Pages

  3. Axxent® Hub

    2 Pages

  4. Rigid Shield

    2 Pages

  5. Controller

    2 Pages

  6. X-ray Source

    2 Pages