Product catalog summary
Overview: The document describes the OptiQ™ and Q2 Plus™ CCO/SvO2 Monitoring System, highlighting its advanced features for hemodynamic monitoring. The system is designed to provide accurate and reliable continuous cardiac output (CCO) and mixed venous oxygen saturation (SvO2) measurements.
Specifications: The OptiQ CCO/SvO2 Pulmonary Artery Catheters have a usable length of 110 cm and are made of 8F PVC. The fully inflated balloon diameter is 13 mm with a capacity of 1.5 cc. The introducer size is 8.5 or 9F, and the distance between markings is 10 cm. The lumen volumes for distal, proximal, and DTPP/RV infusion are 0.8 ml each. The recommended guide wire size for the distal lumen is 0.021 inches.
Key Features:
  • OptiQ Catheters: These catheters use an exclusive algorithm to filter noise artifacts, enhancing the accuracy of CCO data and potentially improving patient safety. They eliminate the need for bolus cardiac output injections, reducing the risk of fluid overload and contamination. Proper thermal coil placement can be confirmed without X-rays.
  • Q2 Plus Computer: Features a large, color-coded screen for clear data communication and large input keys for convenience. It offers faster response to cardiac output changes and uses exclusive 3-wavelength technology for accurate SvO2 measurements. User-selected signal processing modes provide flexibility, and the Quality Signal Indicator (QSI) shows the robustness of the CCO output signal.
Benefits: The system's automatic nature reduces the need for manual interventions, potentially decreasing risks associated with fluid management and contamination. The design allows for efficient and safe monitoring with minimal power requirements.
Usage Caution: The device is restricted to sale by or on the order of a physician or licensed practitioner, as per U.S. federal law.
References: The document cites studies by Aranda M, Mihm FG, et al., and Hecker BR, Brown DL, Wilson, D., supporting the system's efficacy in providing timely and accurate hemodynamic data.
See more

Catalog excerpts

OptiQ | Q2 Plus ™-1

The heart and soul of hemodynamic monitoring. ■ Demonstration Mode Simulated Patient Data The advanced OptiQ System. CC0/Sv02 Monitoring System with the enhanced Q2 Plus. human connections

 Open the catalog to page 1
OptiQ | Q2 Plus ™-2

OptiQ catheters deliver the unparalleled accuracy that has long been recognized as the industry standard.1,2 >> Exclusive, enhanced algorithm provides filtration of noise artifact, allowing OptiQ to minimize signal energy requirements, which may result in more accurate and reliable CCO data, and may potentially improve patient safety. >> Eliminates the need for bolus cardiac output injections because the system is fully automatic. This may reduce the risk of fluid overload and potentially decreases the risk for contamination. >> Proper thermal coil placement can be confirmed without X-rays due...

 Open the catalog to page 2
OptiQ | Q2 Plus ™-3

Option Q2 Pius’" CCO/SVO2 Monitoring System | Q2 Plus Computer Information is accessible at the touch of a button. Main Menu Guided Patient Selup Enter Patient Inlormalion SO2 (Oj Saturation) Setup CCO Selup Bolus CO Td Setup Mark Events Patient History Calculate Values System Configuration L'PiOOWM AAFOW to chow*. ENTER to eonOrn», MENU b Mam Menu MOMITOH b Monitoring Screen \Demonstration Mode Simulated PaTiaiTI Dala. 12:23 AM Standard interactive screens have blue backgrounds. They display the Q2Plus main menu and most of the subsequent interactive screens, and provide option choices or...

 Open the catalog to page 3
OptiQ | Q2 Plus ™-4

OptiQ™ | Q2 Plus™ CCO/SVO2 Monitoring System | Q2 Plus Computer TECHNICAL SPECIFICATIONS OptiQ CCO/Sv02 Pulmonary Artery Catheters* Distal Lumen Minimal Flow Ratef (mL/hr with 100 cm H20 head) Distal Lumen Recommended Guide Wire Size (in) Distal Lumen *Models: OptiQ 52509 Q-tip w/ Heparin, OptiQ 52511 Q-Tip w/o Heparin, OptiQ 52510 J-Tip w/ Heparin +The combined infusion rate through the Proximal and RV/DTPP Lumen should not exceed 500 mL/hr during CCO monitoring. Rx only The enhanced Q2 Plus™ Computer > Large, color-coded screen information > User-selected signal processing modes provide greater...