OptiQ | Q2 Plus ™
4Pages

{{requestButtons}}

Catalog excerpts

OptiQ | Q2 Plus ™ - 1

The heart and soul of hemodynamic monitoring. ■ Demonstration Mode Simulated Patient Data The advanced OptiQ System. CC0/Sv02 Monitoring System with the enhanced Q2 Plus. human connections

Open the catalog to page 1
OptiQ | Q2 Plus ™ - 2

OptiQ catheters deliver the unparalleled accuracy that has long been recognized as the industry standard.1,2 >> Exclusive, enhanced algorithm provides filtration of noise artifact, allowing OptiQ to minimize signal energy requirements, which may result in more accurate and reliable CCO data, and may potentially improve patient safety. >> Eliminates the need for bolus cardiac output injections because the system is fully automatic. This may reduce the risk of fluid overload and potentially decreases the risk for contamination. >> Proper thermal coil placement can be confirmed without X-rays...

Open the catalog to page 2
OptiQ | Q2 Plus ™ - 3

Option Q2 Pius’" CCO/SVO2 Monitoring System | Q2 Plus Computer Information is accessible at the touch of a button. Main Menu Guided Patient Selup Enter Patient Inlormalion SO2 (Oj Saturation) Setup CCO Selup Bolus CO Td Setup Mark Events Patient History Calculate Values System Configuration L'PiOOWM AAFOW to chow*. ENTER to eonOrn», MENU b Mam Menu MOMITOH b Monitoring Screen \Demonstration Mode Simulated PaTiaiTI Dala. 12:23 AM Standard interactive screens have blue backgrounds. They display the Q2Plus main menu and most of the subsequent interactive screens, and provide option choices...

Open the catalog to page 3
OptiQ | Q2 Plus ™ - 4

OptiQ™ | Q2 Plus™ CCO/SVO2 Monitoring System | Q2 Plus Computer TECHNICAL SPECIFICATIONS OptiQ CCO/Sv02 Pulmonary Artery Catheters* Distal Lumen Minimal Flow Ratef (mL/hr with 100 cm H20 head) Distal Lumen Recommended Guide Wire Size (in) Distal Lumen *Models: OptiQ 52509 Q-tip w/ Heparin, OptiQ 52511 Q-Tip w/o Heparin, OptiQ 52510 J-Tip w/ Heparin +The combined infusion rate through the Proximal and RV/DTPP Lumen should not exceed 500 mL/hr during CCO monitoring. Rx only The enhanced Q2 Plus™ Computer > Large, color-coded screen information > User-selected signal processing modes provide...

Open the catalog to page 4

All ICU Medical catalogs and technical brochures

  1. Plum 360™

    7 Pages

  2. ChemoClave

    2 Pages

  3. Transpac IV

    2 Pages

  4. MicroClave®

    2 Pages

  5. SafeSet™

    2 Pages

  6. Tego®

    1 Pages

  7. medOC VMC

    4 Pages

  8. Smart-Y ™

    2 Pages

  9. medOC 8xx ES

    2 Pages

  10. medOC 6xx ES

    2 Pages