1. Catalogs
  2. ICU Medical
  3. OptiQ | Q2 Plus ™

OptiQ | Q2 Plus ™
1 /4Pages

OptiQ | Q2 Plus ™

OptiQ | Q2 Plus ™
1 /4Pages

Catalog excerpts

OptiQ | Q2 Plus ™-1

The heart and soul of hemodynamic monitoring. ■ Demonstration Mode Simulated Patient Data The advanced OptiQ System. CC0/Sv02 Monitoring System with the enhanced Q2 Plus. human connections

 Open the catalog to page 1
OptiQ | Q2 Plus ™-2

OptiQ catheters deliver the unparalleled accuracy that has long been recognized as the industry standard.1,2 >> Exclusive, enhanced algorithm provides filtration of noise artifact, allowing OptiQ to minimize signal energy requirements, which may result in more accurate and reliable CCO data, and may potentially improve patient safety. >> Eliminates the need for bolus cardiac output injections because the system is fully automatic. This may reduce the risk of fluid overload and potentially decreases the risk for contamination. >> Proper thermal coil placement can be confirmed without X-rays due...

 Open the catalog to page 2
OptiQ | Q2 Plus ™-3

Option Q2 Pius’" CCO/SVO2 Monitoring System | Q2 Plus Computer Information is accessible at the touch of a button. Main Menu Guided Patient Selup Enter Patient Inlormalion SO2 (Oj Saturation) Setup CCO Selup Bolus CO Td Setup Mark Events Patient History Calculate Values System Configuration L'PiOOWM AAFOW to chow*. ENTER to eonOrn», MENU b Mam Menu MOMITOH b Monitoring Screen \Demonstration Mode Simulated PaTiaiTI Dala. 12:23 AM Standard interactive screens have blue backgrounds. They display the Q2Plus main menu and most of the subsequent interactive screens, and provide option choices or...

 Open the catalog to page 3
OptiQ | Q2 Plus ™-4

OptiQ™ | Q2 Plus™ CCO/SVO2 Monitoring System | Q2 Plus Computer TECHNICAL SPECIFICATIONS OptiQ CCO/Sv02 Pulmonary Artery Catheters* Distal Lumen Minimal Flow Ratef (mL/hr with 100 cm H20 head) Distal Lumen Recommended Guide Wire Size (in) Distal Lumen *Models: OptiQ 52509 Q-tip w/ Heparin, OptiQ 52511 Q-Tip w/o Heparin, OptiQ 52510 J-Tip w/ Heparin +The combined infusion rate through the Proximal and RV/DTPP Lumen should not exceed 500 mL/hr during CCO monitoring. Rx only The enhanced Q2 Plus™ Computer > Large, color-coded screen information > User-selected signal processing modes provide greater...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.