Pulmonary Artery Catheters
4Pages

{{requestButtons}}

Catalog excerpts

Pulmonary Artery Catheters - 1

Pulmonary Artery Catheters With No Natural Rubber Latex Components Performance you can count on, without the risk of latex allergy. A complete line of pulmonary artery catheters with no natural rubber latex components.

Open the catalog to page 1
Pulmonary Artery Catheters - 2

The problem – latex allergies. Latex allergy or hypersensitivity occurs when the body’s immune system reacts to proteins found in natural rubber latex. A Type I systemic reaction is an immediate hypersensitivity reaction moderated by the development of IgE antibodies to specific proteins in latex, causing a serious and potentially lethal event. A recent study of antilatex IgE antibodies in blood donors has shown that the prevalence of latex sensitivity may be as high as 6-12%1 or up to 37 million people in the U.S. alone. Once sensitized, most individuals are asymptomatic and unaware of...

Open the catalog to page 2
Pulmonary Artery Catheters - 3

Pulmonary Artery Catheters With No Natural Rubber Latex Components The solution – ICU Medical’s extensive portfolio of critical care and advanced sensor catheters with no natural rubber latex components. >> Oximetry (SvO2) Catheters -- TriOx™ >> Continuous Cardiac Output (CCO) Catheters -- TDQ™ >> Standard Pulmonary Artery Pressure & Pulmonary Artery Occlusion Pressure Monitoring Catheters >> Standard PA Thermodilution Catheters -- Multiflex -- Pentalumen™ PA catheters with no natural rubber latex components that cover the full spectrum of patient acuity without compromising product...

Open the catalog to page 3
Pulmonary Artery Catheters - 4

TriOx Oximetry (SvO2) Catheters Standard PAP & PAOP Monitoring Catheters LIST NUMBER LIST NUMBER Multiflex & Pentalumen Standard PA Thermodilution Cathe No No TDQ CCO Catheters_ LIST NUMBER LUMENS* FRENCH SIZE LENGTH HEPARIN OptiQ CCO & Oximetry (SvO2) Catheters LIST NUMBER LIST NUMBER * total infusion lumens icumedical human connections 800.824.7890 | www.icumed.com Eliminate the risk of a latex allergy event for your patients! Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician or other licensed practitioner. ©2012 ICU Medical, Inc. | M1-1244 Rev....

Open the catalog to page 4

All ICU Medical catalogs and technical brochures

  1. Plum 360™

    7 Pages

  2. ChemoClave

    2 Pages

  3. Transpac IV

    2 Pages

  4. MicroClave®

    2 Pages

  5. SafeSet™

    2 Pages

  6. Tego®

    1 Pages

  7. medOC VMC

    4 Pages

  8. Smart-Y ™

    2 Pages

  9. medOC 8xx ES

    2 Pages

  10. medOC 6xx ES

    2 Pages