1. Sample and Device Requirements:
  • Verify the appropriate sample collection device and SNAP device requirements.
  • For evacuated tubes like BD Vacutainer, allow samples to draw naturally by vacuum.
2. Collect and Prepare the Sample:
  • Use the correct serum separator or lithium heparin tube.
  • Draw samples gently and transfer to the appropriate tube.
  • For serum, let the sample clot for at least 20 minutes before centrifugation.
  • Centrifuge samples for at least 120 seconds at a minimum of 12,000 RCF.
3. Prepare the SNAP Device:
  • Dispense the sample into a disposable tube using the correct pipette as indicated on the SNAPshot Dx Analyzer screen.
  • Add the appropriate amount of conjugate to the sample tube and mix by gently inverting 4-5 times.
  • For cortisol tests, incubate the sample for 5 minutes.
  • Pour the entire contents into the SNAP device's sample well.
  • Press the activator when color appears in the activation circle and load the device into the analyzer.
4. Warm-up Requirements:
  • Different SNAP tests require specific warm-up times and conditions, such as room temperature for devices and conjugates.
  • Examples include SNAP Cortisol (10 minutes) and SNAP FIV/FeLV Combo (30 minutes).
5. Customer and Technical Support:
  • Contact information is provided for various regions including the U.S., Europe, Australia, and more.
See more

Catalog excerpts

Preparing Samples for Use on the IDEXX SNAPshot Dx* Analyzer-1

Preparing Samples for Use on the IDEXX SNAPshot Dx* Analyzer n Step 1: Verify Sample and SNAP* Device Requirements Test Type Anticoagulated Whole Blood SNAP* Cortisol Components Requiring Room Temperature Warm-up Warm-up Time Required Pipette Used Gray or Blue (depending on protocol) SNAP* FIV/FeLV Combo Clear (provided) Clear (provided) Clear (provided) Clear (provided) Clear (provided) Clear (provided) SNAP* Feline proBNP EDTA-based plasma n Step 2: Collect and Prepare the Sample Anticoagulated Whole Blood 1. Use the appropriate sample collection device. 1. Use the appropriate serum separator tube. 2. Use the appropriate sample collection device. 1. When the sample drawer is ready, remove the Catalyst* whole blood separator from the sample drawer. 2. Draw the sample gently and transfer it to a treated sample tube. 3. Draw the sample gently and transfer it to a serum tube.‡ 4. Let the sample clot for a minimum of 20 minutes. 2. Aspirate the plasma from the whole blood separator. 1. Use the appropriate lithium heparin tube. 2. Use the appropriate sample collection device. 3. Draw the sample gently and transfer it to a lithium heparin tube.‡ 4. Gently invert the sample for 30 seconds to mix. When using an evacuated tube, such as a BD Vacutainer* tube, allow the sample to draw naturally into the tube by vacuum. When using an evacuated tube, such as a BD Vacutainer* tube, allow the sample to draw naturally into the tube by vacuum. 5. Centrifuge the sample for at least 120 seconds at a minimum of 12,000 RCF. Refer to your centrifuge operator’s manual for centrifugation settings and times. 5. Centrifuge the sample for at least 120 seconds at a minimum of 12,000 RCF. Refer to your centrifuge operator’s manual for centrifugation settings and times. n Step 3: Prepare the SNAP* Device IDEXX Customer and Technical Support U.S./Canada 1-800-248-2483 Europe idexx.eu 1. Following the on-screen instructions on the SNAPshot Dx Analyzer, dispense sample into disposable sample tube. Ensure you use the correct pipette (as indicated on the screen). 2. Dispense the appropriate amount of conjugate into the same sample tube used in step 1. 3. Gently invert the sample tube 4–5 times to mix. 4. Cortisol ONLY: Incubate the sample tube for 5 minutes. activation circle 5. Pour entire contents of sample tube into the sample well of a SNAP* device. 6. When color first appears in the activation circle, press the activator. 7. Immediately load the SNAP device into an available port on the analyzer. © 2022 IDEXX Laboratories, Inc. All rights reserved. • 06-18022-09 *Vacutainer is a registered trademark of Becton, Dickinson and Company. SNAPshot Dx, SNAP, SNAP cPL, SNAP fPL, Catalyst and 4Dx are trademarks or registered trademarks of IDEXX Laboratories, Inc. or its affiliate

 Open the catalog to page 1

All Idexx Laboratories catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.