Product catalog summary
Introduction
Implants Diffusion International (IDI) has been a leader in dental implant innovation and quality since 1987. Their products, manufactured in France, comply with ISO 13485, ISO 9001, and CE certifications, and come with lifetime warranties, highlighting their commitment to customer service and practitioner support.
Quality Commitment
IDI ensures high-quality standards in manufacturing, offering lifetime warranties and training their teams in the latest techniques.
Product Specifications
The IDCAM implant range features a Morse taper connection, designed for ease of placement and improved prosthetic outcomes. Key features include:
  • Ti6Al4V grade 5 alloy
  • Sandblasted and acid-etched surface
  • Cylindro-tapered shape
  • Square and V-shaped threads
  • Switching cone and cam retention
Implant Ranges
The IDCAM range includes:
  • IDCAM ST (Standard) - Convex apex for additional anchorage, suitable for various bone densities.
  • IDCAM M (Mini-threads) - Designed for immediate loading, suitable for specific dental applications.
Surgical Protocol
Detailed surgical protocol for IDCAM implants includes recommended tools and techniques for optimal placement and stability.
Important Considerations
Recommendations include:
  • Using specific implant diameters for certain teeth
  • Positioning implants 1mm under the bone crest for aesthetic quality
  • Determining implant size based on bone density from CT scans
Conclusion
IDI's catalog emphasizes their commitment to innovation, quality, and customer satisfaction, providing comprehensive solutions for practitioners worldwide.
Specifications
The document outlines prosthetic components and kits, specifying dimensions, part numbers, and types of abutments, including standard sizes for IDCST components, healing caps, and screw dimensions.
Procedures
Instructions for using Morse taper abutment removers and IDLOC placement protocol are detailed, along with cleaning and sterilization instructions for surgical sets.
Norms and Recommendations
Prosthetic elements must be used with specific screwdrivers, and implant heights should match color codes on packaging. Torque limits for retaining screws are specified.
Prosthetic Kits
Descriptions of various kits for prosthetic reconstructions, including contents and part numbers, are provided. Differences between fixed screw-on CoNe and PLAN abutments are detailed.
Key Components
Includes implant analogs, burnout cylinders, and various abutments with different transgingival heights and angles, as well as removable prosthesis components like IDUnit and IDLoc attachments.
Graphical Data
Tables list part numbers and dimensions for components, emphasizing the importance of correct tools and procedures for installation and maintenance.
Direct Method for IDLOC Abutment Placement
  • Remove healing caps and insert IDLOC abutment according to gingival tissue height, ensuring it emerges 1mm sub-gingival. Secure with a square-end screwdriver.
  • Place a block-out white spacer on each abutment and fix the box with a nylon ring.
  • Mark the top of the boxes, position the prosthesis, and fill hollowed parts with resin.
  • Position the prosthesis, wait for polymerization, remove excess resin, and reposition the prosthesis.
Indirect Method for IDLOC Placement
  • Remove healing caps and insert IDUNIT abutment, tightening to 25 N.cm. Conduct an X-ray check.
  • Take an impression using closed or open tray.
  • Position the prosthesis and secure with retaining screws, tightening to 25 N.cm.
Instruments and Accessories
  • Various screwdrivers and instruments are available, including ratchets and manual screwdrivers.
  • Double sterile packaging methods are outlined for implant handling.
Packaging Instructions
  • Instructions for handling implants and caps emphasize using specific screwdrivers and techniques.
Company Information
  • Implants Diffusion International, based in Montreuil, France, provides a range of dental implant products and accessories.
See more

Catalog excerpts

2017 PRODUCT CATALOG Morse taper Range / IDCAM-1

IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 Morse taper Range / IDCA

 Open the catalog to page 1
2017 PRODUCT CATALOG Morse taper Range / IDCAM-2

IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS DIFFUSION INTERNATIONAL SinceÊ1987 IMPLANTS Since 25 years, IDI firm (Implants Diffusion International), in collaboration DIFFUSION with a team of researchers, engineers and dental surgeons, has regularly INTERNATIONAL developped new products intended to implantology. Implants Diffusion International invests a great deal in the research of new technologies such as RBS drill, state of surface SMA +Tio2, IMPLANTS DIFFUSION Osteosinus… INTERNATIONAL “WE DEVELOP AND MANUFACTURE IN FRANCE” The IDI lines are developped and manufactured in the Paris...

 Open the catalog to page 2
2017 PRODUCT CATALOG Morse taper Range / IDCAM-3

IDI - Implants Diffusion International - develops, manufactures largest range of dental implants all over the world, as well as implant dental surgery equipment. IDI products are manufactured in France They're resulting from the essential work of the Research and D Department. For IDI, to be close to practitioners, hospitals and implantolo centres is a great deal, because they take part to the constant innovation. The IDI teams, concerned with the trust relationship that they enter into practitioners, decided to offer lifetime warranties to all the implant lines of brand. Proud of our implant...

 Open the catalog to page 3
2017 PRODUCT CATALOG Morse taper Range / IDCAM-4

IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL Implant range and prosthetic systems 05 MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL ACCESSORIES & INSTRUMENTS

 Open the catalog to page 4
2017 PRODUCT CATALOG Morse taper Range / IDCAM-5

“On a surgical aspect IDCAM implants are easier and more pleasant to place comparing to other implants. Furthermore, with RBS drills, we can harvest a great quantity of bone. On a prosthetic aspect, at this time I just have used the kit C for unit implants, and I think that’s an excellent one”

 Open the catalog to page 5
2017 PRODUCT CATALOG Morse taper Range / IDCAM-6

There’s more than 1000 brands of dental implants all over the world. Maximal shearing stress Maximal shearing stress In this tridimensional finite elements study, the shearing force is the same for V-shaped and reverse V-shaped threads. However, the study shows that the squared-shaped thread reduces shearing forces for the same load. Its alloy - Two phases Ti6Al4V grade 5 Studies of Buser (2004), Zhao and Schwartz (2005), Carl E Misch. Its state of surface - Sandblasted and acid-etched and TiO2, Roughness of 1,76m - Sandblasted and acid-etched, passivated. Studies of Becker and Coll, Albrektsson...

 Open the catalog to page 6
2017 PRODUCT CATALOG Morse taper Range / IDCAM-7

MORSE TAPER CONNECTION Concave The concave area allows to sustain grafted biomaterials during sinus lift. Safety The atraumatic round-shaped end limits the risks of damaging neighbouring tissues. Osseointegration The peripheral wedge groove increases the apical bone retention surface. Internal part of IDCAM Cam retention For a better connection accuracy. 2,5° Morse taper Internal Universal ISO threading RADIOGRAPHIC EXAMINATION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL Implant placement in canvas shape Technique of implant placement without...

 Open the catalog to page 7
2017 PRODUCT CATALOG Morse taper Range / IDCAM-8

PRESENTATION The IDCAM ST implant line (type IM)benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress without being affected. The IDCAM ST implant draws special attention to itself due to its Switching Cone neck and to its cylindro-tapered body identical to a dental root. The angulation, the state and the depth of the threads are specially studied to optimize the primary stabilization in any bone density and favor the immediate loading. Switching Cone Condensing high threads Anti-unscrewing groove IDCAM...

 Open the catalog to page 8
2017 PRODUCT CATALOG Morse taper Range / IDCAM-9

MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANT TYPE IMPLANTS DIFFUSION INTERNATIONAL *On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS conical drills for the IDCAM implants : Color code* IDCST 1552 All the dimensions are in millimeters. Important considerations The 3,5mm diameter implants must be used only for lower and upper lateral incisors. The IDCAM implants are supplied with a closing and a healing cap. To improve aesthetic quality,...

 Open the catalog to page 9
2017 PRODUCT CATALOG Morse taper Range / IDCAM-10

PRESENTATION The IDCAM M implant line (type IM) benefits from the SMA + Ti02 state of surface initiated by IDI and used since 1987. This self-condensing implant stands 75 N.cm screwing stress, without being affected. The IDCAM M implant differentiates from the IDCAM S because of its mini threads neck, which favor immediate loading. Switching Cone Condensing mini threads Condensing high threads IDCAM M Implant features - Cylindro-tapered-shaped - 2,5° morse taper - Titanium alloy Ti6Al4V ELI - SMA + Ti02 state of surface Anti-unscrewing groove - Cam retention - Switching Cone - Anti-unscrewing...

 Open the catalog to page 10
2017 PRODUCT CATALOG Morse taper Range / IDCAM-11

MORSE TAPER CONNECTION IMPLANTS DIFFUSION INTERNATIONAL IMPLANTS DIFFUSION INTERNATIONAL IMPLANT TYPE IMPLANTS DIFFUSION INTERNATIONAL *On each implant packaging there is a small colored sticker to match with the implant length. The code for each color is related to the one found on the RBS conical drills for the IDCAM implants : Color code* IMPLANTS DIFFUSION INTERNATIONAL NB: The 8mm length of IDCAM implants (P/N IDCM 0842 and IDCM 0852) do not have any CSO APEX. 10 mm length 12 mm length 15 mm length Important considerations LENGTH 15 The 8mm IDCAM implants do not have any CSO Apex. IDCM 1552...

 Open the catalog to page 11
2017 PRODUCT CATALOG Morse taper Range / IDCAM-12

SURGICAL PROTOCOL EXAMPLE OF AN IDCAM IMPLANT (example with the implant placement for an IDCAM implant P/N: IDCM1242) Use the Pilot drill P/N 1220 of 2mm diameter & 12mm length. Drill at 650 rpm with ample cooling. Use the 3,5mm diameter drill & 12mm length (P/N 123522). Drill with irrigation at 650 rpm. If drilling procedure with bone harvesting: 150 rpm. Use the 4,2mm diameter drill & 12mm length (P/N 124223). Drill with irrigation at 650 rpm. If drilling procedure with bone harvesting: 150 rpm. (This step is to be performed for an implant placement at the mandibule only.) Screw the implant...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.