IITC Catalog 2008
64Pages

{{requestButtons}}

Catalog excerpts

IITC Catalog 2008 - 1

Blood Pressure Behavioral Activity Animal Respirators Temperature Probes Syringe Pumps IITC LIFE SCIENCE

Open the catalog to page 1
IITC Catalog 2008 - 2

BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES IITC Inc Life Science

Open the catalog to page 2
IITC Catalog 2008 - 3

IITC Inc Life Science 818 710 8843

Open the catalog to page 3
IITC Catalog 2008 - 4

Non-Invasive Blood Pressure in rodents (NIBP) We at IITC Life Science are proud of the fact that we have been supplying the best tail cuff blood pressure equipment since 1973 to researchers globally. It is known Non-invasive Blood Pressure (NIBP) testing by tail plethysmography needs elevated ambient temperature. The effect of higher ambient temperature on rodents' blood pressure is also well established in literature. Rats and mice regulate their body temperatures by controlling the amount of blood that flows through their tails. When body temperatures are elevated above normal; either by...

Open the catalog to page 4
IITC Catalog 2008 - 5

NIBP Comparison Document NIBP Comparison Document BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES WHY IS THE IITC INDIRECT BLOOD PRESSURE SYSTEM BETTER THAN OTHERS? Comparison is to other high temperature methods out on the market today Ambient temperature for testing: (Heating) Rats as do other animals have a built-in regulating mechanism; It is called thermoregulation. Their normal ambient temperature is approximately 26-27 deg. c. It is at 28-30 deg. c. the thermoregulation starts an increased blood-flow;...

Open the catalog to page 5
IITC Catalog 2008 - 6

NIBP Multi Channel Blood Pressure Systems NIBP up to 24 animals The IITC Life Science blood pressure systems can be configured from 1-24 animals. All of these systems allow researchers to quickly, and accurately obtain blood pressure measurements at the lowest recommended temperatures. Systems use a highly sensitive photoelectric sensor for detection of blood pressure pulses. The only validated method/data when compared to both telemetry and direct blood pressure. Our method is the only method that allows researchers to measure blood pressure at the lowest ambient temperature which is 32...

Open the catalog to page 6
IITC Catalog 2008 - 7

BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES 12 Animal Blood Pressure System Computer sold separately Features: Validated data: Telemetry Direct blood pressure Data supplied: Systolic Mean Diastolic Heart Rate Lowest temperature method Indirect heating MRI systems available Animal color not a factor USB Optional RS232 Standard Animals: Mice Rats Cats Dogs Rabbits Swine Monkeys Lifetime Warranty IITC Inc Life Science 818 710 8843

Open the catalog to page 7
IITC Catalog 2008 - 8

6 Animal Blood Pressure System 3 Animal Blood Pressure System Computer sold separately BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES IITC Inc Life Science

Open the catalog to page 8
IITC Catalog 2008 - 9

BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES IITC Inc Life Science 818 710 8843

Open the catalog to page 9
IITC Catalog 2008 - 10

For small, short studies and student teaching these systems are an ideal economical solution. Our economical NIBP blood pressure systems are a great entrance into blood pressure research. These systems offer all of the same features as our multi channel systems except for automatic cuff inflation. All systems allow researchers to accurately obtain blood pressure measurements at the lowest recommended temperatures. Systems use a highly sensitive photoelectric sensor for detection of blood pressure pulses. The only validated method/data when compared to both telemetry and direct blood...

Open the catalog to page 10
IITC Catalog 2008 - 11

Economical NIBP Blood Pressure Systems BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES Manual Inflation Systems (upgradeable to 24 animals) Single Animal Warming Chamber Three Animal Warming Chamber IITC Inc Life Science 818 710 8843

Open the catalog to page 11
IITC Catalog 2008 - 12

Features: Validated data: Telemetry Direct blood pressure Data supplied: Systolic Mean Diastolic Heart Rate NIBP System Component Details Amplifier with automatic cuff inflation The IITC amplifier with built in cuff inflation pump is a basic system that allows testing of a single animal at a time. The method is done noninvasive via the tail cuff method. The IITC method requires minimal warming of rats and mice. The rodents should be warmed to an ambient temperature of 30 deg. c. for rats and 32 deg. c. for mice, which is well below the thermostress level (see NIBP Intro. page). It is...

Open the catalog to page 12
IITC Catalog 2008 - 13

NIBP System Component Details BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES Amplifier, Manual Inflation The IITC amplifier with manual inflation is a basic system that allows testing of a single animal at a time. This is a noninvasive tail cuff method. The IITC method requires minimal warming of rats and mice. The rodents should be warmed to an ambient temperature of 30 deg. c. for rats and 32 deg. c. for mice, which is well below the thermostress level (see NIBP Intro. page). It is suggested to use one of...

Open the catalog to page 13
IITC Catalog 2008 - 14

NIBP System Component Details Automatic Cuff Pump The IITC automatic inflation cuff pump is a dedicated cuff pump for small animal noninvasive blood pressure testing. This cuff pump replaces manual inflation and can be used with all of IITC's indirect blood pressure test systems. The IITC cuff pump has an adjustable cut-off pressure in 50 mmHg increments, adjustable deflation rate calibrated in mmHg and test termination pressure. The maximum pressure is 300 mmHg and higher. The test termination pressure feature allows the tests to be performed in 10-15 seconds. Single or repetitive cycles...

Open the catalog to page 14
IITC Catalog 2008 - 15

NIBP System Component Details BLOOD PRESSURE RESTRAINERS CATHETERS ANALGESIA BEHAVIORAL/ACTIVITY ANIMAL RESPIRATORS SYRINGE PUMPS TEMPERATURE PROBES Animal Warming Chambers The IITC test chambers offer the perfect uniform test environment when measuring blood pressure noninvasive via the tail cuff method on mice and rats. Offering 1, 3, 6, 12 and 24 channels. The chamber temperature is adjustable and stays at a constant temperature within 1 degree c. at all times via the digitally controlled built in temperature controller. Chambers are ideal for testing from 30 to 40 degrees c....

Open the catalog to page 15