Overview: The MiSeq system by Illumina offers a comprehensive solution for targeted and small-genome sequencing. It combines optimized sample preparation kits, automated sequencing, and data analysis, providing a streamlined workflow from sample to data in a single day.
Key Features:
  • Applications: The system supports a wide range of applications including amplicon sequencing, de novo sequencing, resequencing, metagenomics, RNA sequencing, and more.
  • Sample Preparation: The Nextera XT DNA Sample Prep Kit allows for rapid sample preparation, completing the process in as little as 90 minutes with minimal hands-on time.
  • Data Analysis: Data can be stored, analyzed, and shared via Illumina’s BaseSpace cloud, eliminating the need for additional hardware.
Sample Preparation Kits:
  • Nextera XT DNA Sample Prep Kit: Provides a fast and easy solution for amplicon and small-genome sequencing, with DNA fragmentation and tagging in one step.
  • TruSeq Custom Amplicon Kit: Offers a highly multiplexed assay for variant identification, suitable for a wide range of samples.
Performance:
  • The MiSeq system is capable of automated paired-end reads and can deliver up to 15 Gb per run, providing over 600 bases of sequence information.
  • It supports various read lengths tailored to specific applications, such as 1 × 250 for targeted resequencing and 2 × 300 for small-genome sequencing.
Conclusion: The MiSeq system is designed to empower research with its extensive applications portfolio and user-friendly interface, facilitating rapid and accurate sequencing results.
See more

Catalog excerpts

Miseq system application-1

MiSeq® system applications

 Open the catalog to page 1
Miseq system application-2

Choose your application. Load, and go. Focused power. Speed and simplicity for targeted and small-genome sequencing. Optimized sample preparation kits, push-button sequencing, and automated data analysis create the first end-to-end sequencing solution. MiSeq delivers a simple workflow and accurate data for access to a wide breadth of applications. And no need for extra hardware—store, analyze, and share data with Illumina’s BaseSpace® cloud. Sample to data in a single day. All at the touch of a button. Amplicon Sequencing Custom Amplicon Amplicon Sequencing Targeted Resequencing Custom Enrichment...

 Open the catalog to page 2
Miseq system application-3

Targeted Resequencing Custom Amplicon Clone Resequencing Checking Resequencing ChIP-Seq Resequencing Custom ChIP-Seq Amplicon Amplicon Sequencing RNA de novo Resequencing Targeted Sequencing Sequencing Resequencing Amplicon Sequencing Custom RNA Enrichment Sequencing Custom Amplicon Custom Enrichment Targeted Resequencing Small Small RNA Genome Sequencing Custom Enrichment Small Genome RNA-Seq Clone Checking Amplicon Sequencing Small Genome Custom Genome Amplicon Targeted uencing sequencing Library QC argeted equencing Custom Enrichment Custom Amplicon Custom Enrichment Custom Enrichment Targeted...

 Open the catalog to page 3
Miseq system application-4

The fastest and easiest sample prep. Nextera XT DNA Sample Prep Kit ® Nextera technology combines with the MiSeq system to provide the fastest and easiest solution for amplicon and small-genome sequencing. In one quick step, DNA is simultaneously fragmented and tagged with sequencing adapters to deliver libraries that can be rapidly sequenced with the MiSeq system. Rapid sample preparation Complete sample prep in as little as 90 minutes with only 15 minutes of hands-on time Fastest time to results Go from DNA to data in only 8 hours Optimized for small genomes, PCR amplicons, and plasmids One...

 Open the catalog to page 4
Miseq system application-5

Amplicon sequencing transformed. TruSeq Custom Amplicon Kit ® Optimized for the MiSeq system, TruSeq Custom Amplicon (TSCA) offers a highly multiplexed amplicon and sample assay for powerful, fast, and cost-effective variant identification. Requiring just 150 ng of starting gDNA, TSCA is amenable to a wide range of samples, including non-human samples and samples available in limited quantity. Data analysis is performed directly on the MiSeq system, providing quick, easy-to-interpret results for both germline and somatic variation. Simplest assay customization Easily create projects online with...

 Open the catalog to page 5
Miseq system application-6

The widest breadth of sequencing applications. MiSeq is capable of automated paired-end reads and up to 15 Gb per run, delivering over 600 bases of sequence information. Sample prep kits are optimized for a variety of applications. Empower your research with the MiSeq system. Recommended Read Length Illumina Solution Targeted Resequencing Amplicon Sequencing (tens of targets) Amplicon Sequencing (hundreds of targets) Hybrid Capture (thousands of targets) Clone Checking Small-Genome Sequencing De novo RNA Sequencing Small RNA Sequencing RNA-Seq (microbial)† Quality Control Library QC Regulation...

 Open the catalog to page 6
Miseq system application-7

MiSeq system applications Focused power. Speed and simplicity for targeted and small-genome sequencing. With the largest applications portfolio at your fingertips. And, access to an entire community of users and tools with BaseSpace. All designed to move your research forward. The pocket inserts showcase just a few of the applications we’ve explored with the MiSeq system. And this is just the beginning. Learn more at www.illumina.com/miseq

 Open the catalog to page 7
Miseq system application-8

www.illumina.com FOR RESEARCH USE ONLY © 2011-2014 Illumina, Inc. All rights reserved. llumina, IlluminaDx, BaseSpace, BeadArray, BeadXpress, cBot, CSPro, DASL, DesignStudio, Eco, GAIIx, Genetic Energy, Genome Analyzer, GenomeStudio, GoldenGate, HiScan, HiSeq, Infinium, iSelect, MiSeq, Nextera, NextSeq, NuPCR, SeqMonitor, Solexa, TruSeq, TruSight, VeraCode, the pumpkin orange color, and the Genetic Energy streaming bases design are trademarks or registered trademarks of Illumina, Inc. All other brands and names contained herein are the property of their respective owners. Pub. No. 770-2011-023...

 Open the catalog to page 8

All Illumina catalogs and technical brochures

  1. iSeq 100

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.