iQ-ROUTER
8Pages

{{requestButtons}}

Catalog excerpts

iQ-ROUTER - 1

Image compression, teleradiology and workflow management taking teleradiolOgy to the next level

Open the catalog to page 1
iQ-ROUTER - 2

iQ-ROUTER accelerates the transmission of any medical image through any network DICOM compatible image data is forwarded up to eight times faster as it is sent in a lossless compressed format. iQ-ROUTER is the ideal tool for In standard DICOM networks, na- iQ-ROUTER offers bidirectional com- any frequently used and/or criti- tive (uncompressed) DICOM trans- munication which means that mo- cal connection between imag- missions via wide area networks dalities can not only receive data ing centers. It works with state-of- generate bottle necks and cause over the teleradiology line, but they...

Open the catalog to page 2
iQ-ROUTER - 3

iQ-ROUTER supports virtually all DI- The PRO version includes data for- iQ-ROUTER PRO is the world’s first COM formats and transfer syntaxes, warding based on a specific rule and only DICOM product that incor- thus making the software excep- or even a combination of them - porates Regular Expressions. Based tionally versatile. for example, to forward all incom- on user-defined rules, the software ing CT scans of the skull to a certain automatically corrects virtually any destination. This facilitates setting image or data error as well as DI- SSL protocol, privacy between two up...

Open the catalog to page 3
iQ-ROUTER - 4

iQ-ROUTER WORKFLOW (BASIC & PRO) iQ-ROUTER BASIC iQ-ROUTER BASIC iQ-ROUTER BASIC lossless or lossy transmission (predefined by the user) of DICOM objects from one or more given nodes in a local network to the same number of nodes in another network (point-topoint communication). Modality 2 iQ-ROUTER BASIC DICOM objects from one node in a local network to multiple nodes in another network. This is done by using customizable forwarding rules. The transmission can be either lossy or lossless. Workstation e.g. iQ-VIEW

Open the catalog to page 4
iQ-ROUTER - 5

iQ-ROUTER WORKFLOW (PREMIUM) External PACS Target PACS iQ-ROUTER PREMIUM iQ-ROUTER BASIC iQ-ROUTER PREMIUM ensures data consistency between multiple imaging centers. 1 iQ-ROUTER PREMIUM receives a DICOM object from an external PACS, e.g. via iQ-ROUTER 2 iQ-ROUTER PREMIUM queries the HIS/ RIS Master Patient Index (MPI) master patient index of a connected HIS by HL7 (MPI) or DICOM for the target patient ID and accession number 3 iQ-ROUTER PREMIUM adjusts the dataset with the target patient ID and accession number 4 iQ-ROUTER PREMIUM forwards the data to the target PACS External PACS iQ-ROUTER...

Open the catalog to page 5
iQ-ROUTER - 6

iQ-ROUTER Features Runs without user login (NT service controlled by the OS) Flexible logging, monitoring and configuration tool DICOM SUPPORT DICOM store, query/retrieve, verification Support of all DICOM-defined “specific character sets“ including Asian languages and unicode UTF-8 Fully parallel processing (multi-threaded) Support of all DICOM store classes including non-image classes like Structured Reports Unlimited number of parallel connections and modalities within the network Transparent routing of all requests Bidirectional DICOM-interface Patient root and study root model support...

Open the catalog to page 6
iQ-ROUTER - 7

iQ-ROUTER PRO FEATURES in Addition to iQ-ROUTER Features DICOM SUPPORT Rule-based modification of DICOM attributes Definable conditions to set the rules: attributes, AE title source (calling AE), AE title destination (called AE) Possible modifications of attributes: add, replace, copy, delete, add prefix or suffix Regular Expressions for fully automatic correction of any image and data errors or DICOM inconsistencies (NEW!) WORKFLOW Automatic rule-based forwarding of DICOM data to multiple destinations Definable conditions to set the rules: attributes, AE title source, AE title destination,...

Open the catalog to page 7
iQ-ROUTER - 8

Picture proof: Pictures by www.Fotolia.de ■ www.istockphoto.com ■ www.shutterstock.com ©2016"^^ IMAGE Information Systems Ltd.-Medical Imaging with IQ! iQ-ROUTER2.1 PUBINT EN003R oUR PRODUCTS FOR YOUR IMAGING NEEDS iQ-SYSTEM PACS iQ-RIS MED-TAB™ IMAGE INfORMATION SYSTEMS LTD. 3RD fLOOR | 207 Regent STREET | London w1B 3HH | United Kingdom Tel. UK: +44 20 3289 1500 Tel. GER: +49 381 496 5820 | fax GER: +49 381 496 582 99 TEL. US: +1 704 323 6663 INfO@IMAGE-SYSTEMS.BIZ | www.IMAGE-SYSTEMS.BIz

Open the catalog to page 8

All IMAGE Information Systems catalogs and technical brochures

  1. iQ-ROBOT

    6 Pages

  2. iQ-PRINT

    4 Pages

  3. DICOMReader

    6 Pages

  4. OrthoView™

    4 Pages

  5. iQ-LAUNCHER

    1 Pages

  6. iQ-DASHBOARD

    2 Pages

  7. iQ-WEBX WADO

    2 Pages

  8. iQ-WEB2GO

    2 Pages

  9. iQ-X

    2 Pages

  10. iQ-4VIEW

    2 Pages

  11. iQ-WEB

    8 Pages

  12. iQ-CAPTURE

    2 Pages

  13. iQ-3D

    2 Pages

  14. iQ-LITE

    2 Pages

  15. iQ-VIEW

    8 Pages

  16. MED-TAB

    4 Pages

  17. IQ 3D view

    7 Pages