cad

3 cm Rotary Valves
1 / 3Pages

Catalog excerpts

3 cm Rotary Valves - 1

Life Science IMI Adaptas 3 cm Rotary Valves – Designed for use with Cadent™ 3 syringe pumps and Kloehn 3 cm syringes – Bi-directional flow valves; not intended for use as shut-off or relief valves – Rated to 100psig (6.89barg) – Available in plug style with PTFE or in face style with PPS/XP-113 or Ceramic – Highly inert to most chemistries and designed for long life – Available in distribution and non-distribution configurations – Suitable for use in analytical, biotechnology and diagnostics instruments Technical features Physical Valve overall dimensions diameter: 1.40 in. Length: 1.78 in. 1.91 in. (8-way) 2.30 in. (12-way) Mass: 30 grams Chemical (wetted) Orifice size: See table for available diameters Operating humidity: 5% to 95% relative humidity, non-condensing at 40°C (104°F) Port specifications: 1/4-28 flat bottom threaded ports, 0.245” deep Storage temperature: –33°C … 71°C (–27°F … 160°F) WEEE & RoHS Compliant Rated pressure: Vacuum *2) to 100 psig (6.89 barg) Syringe locking set screw torque: 1.0 in-lbs. Life cycle *1) (minimum): 100,000 [Plug] 100,000 [Plastic Face Seal] 500,000 [Ceramic Face Seal] Valve mounting hardware (supplied) torque: 5.0 in-lbs. *1) Tested with DI water using IMI standard protocol *2) Vacuum pressure: -25inHg maximum at 2750ft elevation (1psia max). Valve flow configuration types Distribution Distribution valves have a flow path configuration that connects the syringe port to any of the other fluid ports through a central common port. Flow is bi-directional for each connection. The naming of each valve type is determined by the number of ports available to connect with the syringe port (the syringe port is not counted). Non-Distribution A non-distribution valve connects adjacent ports on a valve to allow fluid to flow between them. Fluid may be drawn into the syringe only from one of the adjacent ports. Non-distribution valves allow a “bypass” fluid path where the fluid flows through the valve without entering the syringe. An external pressure system is required to move fluids through any flow paths not involving the syringe port. The naming of each valve type is determined by the number of possible fluid paths. Syringe Syringe Syringe Possible flow paths on a 3-Way Distribution Valve Possible flow paths on a 4-Way Non-Distribution Valve Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2023 - PDS-0031 REV. 6)

Open the catalog to page 1
3 cm Rotary Valves - 2

Face seal valves - ceramic P/N Face seal valves - plastic Orifice size Internal volume Orifice size Internal volume Teflon, 0.070” ID Hole, for 0.059” orifice Teflon, 0.095” ID Hole, for 0.076” orifice Teflon, 0.125” ID Hole, for 0.089” orifice Teflon, No hole, for port plug Wetted materials: PEEK, Alumina Ceramic, FFKM PTFE For customization requests, contact us at IMIKloehncustomersupport@imi-precision.com Valve type Valve type Weep Hole Fitting - PEEK Weep Hole Fitting - Stainless Steel Port Plug Screw, use with seal p/n 18781 Seal washers Dimensions in inches [mm] Projection/third angle...

Open the catalog to page 2
3 cm Rotary Valves - 3

Plug valves Orifice size Internal volume Valve type Orifice size Internal volume Wetted materials: PCTFE, PTFE For customization requests, contact us at IMIKloehncustomersupport@imi-precision.com Valve type Weep Hole Fitting - PEEK Weep Hole Fitting - Stainless Steel Port Plug Screw, use with seal p/n 18781 Teflon, 0.070” ID Hole, for 0.059” orifice Teflon, 0.095” ID Hole, for 0.076” orifice Teflon, 0.125” ID Hole, for 0.089” orifice Teflon, No hole, for port plug Dimensions in inches [mm] Projection/third angle 6-way distribution valve shown Warning Improper selection, misuse, age or...

Open the catalog to page 3

All IMI Life Science catalogs and technical brochures

  1. Flow Meters

    1 Pages