FAS 8 mm CHIPSOL MS Direct acting solenoid valve > 2/2 NC Media separated Cartridge or manifold mounting > Low internal volume, virtually no unswept volume > Very compact design (0 8 x 21 mm) > Low power consumption (0,5 W) > Long life up to 30 million cycles > 100% ED operation up to 50°C fluid temperature Mounting: Cartridge or manifold Size: 8 mm Orifice: 0,8 mm Response time: < 15 ms Response time measured according to ISO 12238 Technical features Medium: Neutral or aggressive gases and liquids Operation: Direct acting 2-way valves, normally closed Operating pressure: 0 ... 2,1 bar (0 ... 30 psi) at port 1 0 ... 0,2 bar (0 ... 2,9 psi) at port 2 0,5 bar (7,2 psi) maximum back pressure at port 2 Life expectancy: >30 Mio. cycles Ambient/media temperature: -10 ... +50 °C (+14 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2 °C (+35°F). Materials: Body in contact with media: PEEK Seat seals: EPDM or FFPM Electrical details    Following options on request Insulation class    F (155°C)    Electric connection Voltage (3, 5 or 6 V d.c.) Manifold for catridge version Sub-base material Pulse width modulation (PWM) control A PWM can be used to control the valve and should be set as follows: Definition    Value to be applied Hit voltage    Voltage used for he valve to commute    Valve nominal voltage Holding voltage    Voltage applied to he valve after commutation    Set duty cycle to guarantee specified holding voltage. 50% of nominal voltage can be used if no value specified. Hit time    Maximum time required to ensure full valve commutation    40 ms at T > 15 °C *1) *1) Please contact us for application outside of those conditions. Precision Engineering Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2014 - 5016c) © 2015 Fluid Automation Systems s.a.

 Open the catalog to page 1

FAS 8 mm CHIPSOL MS Direct acting solenoid valve Technical data - standard models Symbol Mounting option Seal Material Electrical connection 300 mm flying leads mounted with 4 mm (or 2 x 2 mm) pitch SIL socket housing (Harwin M22-3010300) Manifold (PEEK) S140.0361 (M5 ports) S140.0362 (1/4-28 UNF ports) *1) Two valve mounting screws are in scope of delivery Typically flow rate vs back pressure l/min Back pressure Typically response time vs temperature Response time Electric (TE) Pneumatic (T on 10%) Pneumatic (T off 90%) Our policy is one of continued research and development. We therefore...

 Open the catalog to page 2

FAS 8 mm CHIPSOL MS Direct acting solenoid valve Dimensions Cartridge valve Dimensions shown in mm Projection/First angle Outlet port Inlet port Pins ø 1 h8 x >10 (ISO 2338) not in scope of delivery Sealing area All valves are supplied with gasket. Mounting screws are in scope of delivery for manifold valve as well. Manifold Model: S140.0361 (M5); S140.0362 (1/4-28 UNF) (PEEK) Threads for mounting screws - M2 x 5 mm deep Mounting hole Threads to fix valve in position - M1,6 x 6 mm deep Sealing surface Port size M5 or 1/4-28 UNF Warning These products are intended for use in industrial...

 Open the catalog to page 3

All IMI Precision Engineering catalogs and technical brochures

  1. EXPRESS CATALOGUE

    228 Pages

  2. V6 Syringe Pump

    4 Pages

  3. IMI FAS CHIPSOL

    4 Pages

  4. PICOSOL MS

    2 Pages