video corpo cad

IMI FAS CHIPSOL - 4 Pages

Add to MyMedicalExpo favorites
IMI FAS CHIPSOL

Catalog excerpts

FAS 8 mm CHIPSOL Direct acting solenoid valve > 2/2, 3/2 NC/NO; Cartridge mounting > Very compact design (0 8 x 19 mm) > Low power consumption (0,5 W) > Long life up to 100 million cycles > High flow to size ratio Mounting: Cartridge Size: 8 mm Orifice: 0,5 ... 1 mm Response time: 5 ... 10 ms Response time measured according to ISO 12238 Life expectancy: >100 Mio. cycles Technical features Medium: Air, oxygen, neutral gases (10 % ... 95 % humidity, non condensing), 40 gm filtered Operation: Direct acting 2-way and 3-way valves Normally closed and normally opened Operating pressure: 0 ... 8 bar (0 ... 116 psi) Mounting instruction: The valve must be assembled in its housing with a lubricant that is compatible with the seals. Max axial force supported by the valve: 75 (N). Ambient/media temperature: -10 ... +50 °C (+14 ... +122°F) Air supply must be dry enough to avoid ice formation at temperatures below +2 °C (+35°F). Materials: Body: PPS Seat seals: HNBR Internal parts: stainless steel Electrical details    Following options on request Insulation class    F (155°C)    Body Seal Electric connection Voltage (3, 5, 6 or 12 V d.c.) Degreased for oxygen use Pulse width modulation (PWM) control A PWM can be used to control the valve and should be set as follows: Definition    Value to be applied Hit voltage    Voltage used for he valve to commute    Valve nominal voltage Holding voltage    Voltage applied to he valve after commutation    Set duty cycle to guarantee specified holding voltage. 50% of nominal voltage can be used if no value specified. Hit time    Maximum time required to ensure full valve commutation    25 ms *1) *1) Note: There is no temperature restriction in the case of CHIPSOL Precision Engineering Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2006 - 5015d) © 2015 Fluid Automation Systems s.a.

 Open the catalog to page 1

FAS 8 mm CHIPSOL Direct acting solenoid valve Technical data - standard models - 24 V d.c. Symbol kv factor *1) Operating pressure (bar) Seal Material *1) Cv = 0,07 kv 1 3 Accessories 2 10 Test manifold with M3 ports, 1 12 position Electrical connection Test manifold with M3 ports, multiple channels up to 10 positions Barbs mounting interface for Ø 2,5 mm ID tubing (up to 1 bar) 300 mm flying leads mounted with 4 mm (or 2 x 2 mm) pitch SIL socket housing (Harwin M22-3010300) *1) Two valve mounting screws are in scope of delivery Our policy is one of continued research and development. We...

 Open the catalog to page 2

FAS 8 mm CHIPSOL Direct acting solenoid valve Dimensions shown in mm Projection/First angle Faces to be aligned by retaining means Inlet port Outlet port Exhaust port Do not weld Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specificatio

 Open the catalog to page 3

Dimensions Test manifold, 1 position (Aluminium) Barbs mounting interface (Plastic, maximum operating pressure 1 bar) Dimensions shown in mm Projection/First angle Test manifold, up to 10 positions (Brass) 6,1 0 Mounting holes 0 Put in a screw to fix valve position 0 Chipsol mounting hole 0 Clip cover closed CHIPSOL mounting hole 0 Tubing ID 2,5 mm Warning These products are intended for use in air, oxygen and neutral gas systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features«. Before using these products with fluids other...

 Open the catalog to page 4

All IMI Precision Engineering catalogs and technical brochures

  1. EXPRESS CATALOGUE

    228 Pages

  2. V6 Syringe Pump

    4 Pages

  3. PICOSOL MS

    2 Pages

  4. CHIPSOL MS

    3 Pages