InterActive
1 /24Pages

InterActive

InterActive
1 /24Pages

Catalog excerpts

InterActive-2

Table of Contents Page # Implant Design & Surface 2 2-3 Fixture Mount & Impression Technique Selection Chart Lab, Engaging & Non-Engaging Abutments Surgical & Prosthetic Instruments Procedures for Contoured Abutments 13 Selection Chart for Overdenture & Screw-Retained Restorations Healing Collars, Transfers & Analogs 10 Straight & Angled Contoured, Titanium & Zirconia Abutments InterActive™ Implants Straight Abutment & Ancillary Components Implant Dimensions Overdenture & Screw-Receiving Abutment Ancillary Products Surgical Drills, Sequence & Tray

 Open the catalog to page 2
InterActive-3

Implant Design & Surface Simply Smarter Implant Design The InterActive™ implant body features a straight top 1/3rd with micro-grooves to improve soft tissue attachment and microthreads to increase stability and reduce stress in the crestal bone area. The quadruple-lead micro-threads transition to double-lead buttress threads over the bottom 2/3rds which is tapered to facilitate insertion into an undersized socket in soft bone providing compression that increases initial stability (G. Niznick: Clinical Oral Health 2000 “ Achieving Success in Soft Bone”). The slight body taper of the apical 1/3rd...

 Open the catalog to page 3
InterActive-4

InterActive™ Implant Dimensions 1.4mmL Zone Micro-grooves 2.3mmL Zone Micro-threads 2.3mmL Zone Micro-threads M1.6 Internal Thread Double-lead Buttress Threads M1.6 Internal Thread 3.0mmD Platform with a 2.3mmD Internal Hex Double-lead Buttress Threads 3.2mmD InterActive™ 2.6mmD Apex Diameter 3.7mmD InterActive™ 3.0mmD Apex Diameter 2.3mmL Zone Micro-threads M2 Internal Thread Length + 0.25mm Double-lead Buttress Threads 3.4mmD Platform with a 2.7mmD Internal Hex M2 Internal Thread Length + 0.25mm Double-lead Buttress Threads SBM Texture 4.3mmD InterActive™ 3.4mmD Apex Diameter 5.0mmD InterActive™...

 Open the catalog to page 4
InterActive-5

InterActive™ Fixture-Mount & Impression Technique InterActive™ Implant is mounted on a revolutionary two-piece color-coded fixture-mount. The top fails at excessive torques to protect the interface during insertion and detaches in impression for the accuracy of an open-tray transfer with the simplicity of a closed-tray. The fixture-mount may be shortened at the line to function as a final preparable abutment. A healing collar is included in each vial. Each implant is packaged in a sterile vial Vial labels are color-coded with two tear-off labels Cap labels are color-coded by platform diameter...

 Open the catalog to page 5
InterActive-6

InterActive™ InterActive™ Implant System Features & Benefits InterActive™ Packaging • Internal conical connection compatible with NobelActive® and NobelReplace® CC • Revolutionary two-piece fixture-mount. Top includes torque-safety feature and detaches in impression for the accuracy of an open-tray transfer with the simplicity of a closed-tray. This technique supports both implant-level and abutment-level impressions. • 2mm extender retained by cover screw for use as a healing collar for one-stage surgery features a concave transgingival profile which matches the fixture-mount. • Micro-grooves...

 Open the catalog to page 6
InterActive-7

InterActive™: Two-Piece Implant InterActive™ Includes Fixture Mount with Tri-Grip™ Fixation Screw, Extender and Cover Screw. Extender NOT supplied with 6mmL implant SBActive­ Code Replacement Surgical Cover Screws Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or­­­­­­Straumann SCS Driver

 Open the catalog to page 7
InterActive-8

InterActive™ Selection Chart Cover Screw

 Open the catalog to page 8
InterActive-9

Narrow Carrier/Transfer

 Open the catalog to page 9
InterActive-10

Healing Collars, Transfers & Analogs Narrow Healing Collars Healing Collars Closed-Tray Implant Transfers Open-Tray Implant Transfers Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or­­­­­­Straumann SCS Driver Wide Healing Collars Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or­­­­­­Straumann SCS Driver Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or­­­­­­Straumann SCS Driver Includes Tri-Grip™ Fixation Screw Includes Tri-Grip™ Fixation Screw Implant...

 Open the catalog to page 10
InterActive-11

Straight Abutments, Snap-on Transfers & Lab Analogs Straight Abutments Kits Includes Straight Abutment Transfer, Analog, Castable Coping, Comfort Cap & Fixation Screw with Tri-Grip™ Abutment Width Collar Heights Replacement Screw Straight Abutment Transfers Code Abutment Width Straight Abutment Comfort Caps Abutment Width

 Open the catalog to page 11
InterActive-12

Clinical & Laboratory Procedures for Contoured Abutments Orienting the 15º Angled Abutment The flat side of the Fixture Mount/Transfer [Fig. 1] and the angle of the 15° abutment [Fig. 2] are manufactured to align with the flat of the implant’s hex. Fig. 2 The two-piece, 15º Angled Abutment consists of an angled body and a fixation screw Fixture Mount/Transfer To establish the optimum angle of the abutment, index the flat surface of the Fixture Mount/Transfer either toward or away from the desired direction of abutment angle at the time of implant placement. Option 1: Attaching an Angled Abutment...

 Open the catalog to page 12
InterActive-13

Fixture-Mounts, Analogs, Straight & Angled Contoured Titanium Abutments Fixture-Mounts Includes Tri-Grip™ Fixation Screw Fixture-Mount Analogs- Concave Profile Straight Titanium Contoured Abutments Includes Tri-Grip™ Fixation Screw 15º Angled Titanium Contoured Abutments Includes Tri-Grip™ Fixation Screw

 Open the catalog to page 13
InterActive-14

Zirconia Abutments 0°, 8° & 15° Zirconia Contoured Abutments Price includes Fixation Screw with 1.25mmD Hex Replacement Fixation Screws Components include Tri-Grip™ feature for use with 1.25mmD Hex Tool, Nobel Unigrip ScrewDriver or­­­­­­Straumann SCS Driver. Short (S) screws are Dual-Grip™ (S) screws are Dual-Grip™ for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver.

 Open the catalog to page 14

All Implant Direct Europe catalogs and technical brochures

  1. Spectra®

    36  Pages

  2. Legacy

    32  Pages

Archived catalogs

  1. InterActive Old

    24  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.