Table of Contents Page # Implant Design, Surface & Dimensions Labeling & Fixture-Mount Packaging Cover Screws, Healing Collars, Transfers & Analogs Screw-Receiving, Ball & GPSTM Abutments Surgical Tray Gold, Engaging & Non-Engaging Abutments Overdenture & Screw-Receiving Abutment Ancillary Products Straight Abutment & Ancillary Components Selection Chart for Overdenture & Screw-Retained Restorations Selection Chart for LegacyTM Systems 19 Straight & Angled Contoured, Titanium & Zirconia Abutments Instruments, Surgical Drills & Surgical Sequence

Open the catalog to page 2
Legacy - 3

Implant Design & Surface Mini-threads with Double-lead Threads for Faster Insertion The bodies of the LegacyTM1, LegacyTM2, LegacyTM3 and LegacyTM4 implants are tapered to facilitate insertion in an undersized socket (stop at intermediate drill) for expansion in soft bone. This increases initial stability (G. Niznick: Clinical Oral Health 2000 “Achieving Success in Soft Bone”). The SBM textured surface extends over the entire endosseous portion of the LegacyTM system implants. Mini-threads start 1mm below the crest of the bone and extend for 2.0-2.5mm before transitioning into double-lead...

Open the catalog to page 3
Legacy - 4

0.25mmL Bevel Taper starts at 1mm 2.0mmL Zone Mini-threads 1-72UNF Internal Thread 3.5mmD Platform with a 2.5mmD Internal Hex 1-72UNF Internal Thread Length + 0.25mm 0.25mmL Bevel Taper starts at 1mm 1-72UNF Internal Thread Length + 0.25mm SBM Texture 4.5mmD Platform with a 2.5mmD Internal Hex 4.7mmD LegacyTM1 4.1mmD Apex Diameter 5.7mmD Body 5.7mmD Platform with a 3.0mmD Internal Hex

Open the catalog to page 4
Legacy - 5

1.6 UNM Internal Thread Length + 0.25mm Double-lead Buttress Threads 3.0mmD Platform with a Double Internal Hex 2.25mmD (upper) and 2.0mmD (lower) 3.2mmD Legacy 2 and Legacy 4 2.3mmD Apex Diameter 1-72UNF Internal Thread Taper starts at 4.5mm Double-lead Buttress Threads 3.5mmD Platform with a 2.5mmD Internal Hex 1-72UNF Internal Thread Taper starts at 4.5mm Double-lead Buttress Threads Double-lead Buttress Threads 4.5mmD Platform with a 2.5mmD Internal Hex Double-lead Buttress Threads

Open the catalog to page 5
Legacy - 6

2.0mmL Zone Mini-threads 1-72UNF Internal Thread Double-lead Buttress Threads 1-72UNF Internal Thread 5.7mmD Platform with a 3.0mmD Internal Hex Double-lead Buttress Threads 0.25mmL Bevel Taper starts at 1.25mm 1.6 UNM Internal Thread Length + 0.25mm Double-lead Buttress Threads 3.0mmD Platform with a Double Internal Hex 2.25mmD (upper) and 2.0mmD (lower)

Open the catalog to page 6
Legacy - 7

3.7mmD Body Taper starts at 1.25mm 1-72UNF Internal Thread Length + 0.25mm Double-lead Buttress Threads 3.5mmD Platform with a 2.5mmD Internal Hex 4.7mmD Body Taper starts at 1.25mm Double-lead Buttress Threads 0.25mmL Bevel Taper starts at 1.25mm 1-72UNF Internal Thread Length + 0.25mm Double-lead Buttress Threads 4.5mmD Platform with a 2.5mmD Internal Hex 5.7mmD Body Taper starts at 1.25mm Double-lead Buttress Threads 1-72UNF Internal Thread Length + 0.25mm Double-lead Buttress Threads 5.7mmD Platform with a 3.0mmD Internal Hex Double-lead Buttress Threads

Open the catalog to page 7
Legacy - 8

LegacyTM1 LegacyTM1 Implant System Features & Benefits • Internal connection with 1.5mm long hex & internal bevel • Tapered body allows insertion using Tapered Screw-Vent® drills (except the 5.7mmD implant uses 5.4/4.8mmD Step Drill) • Surface options: SBM (Soluble Blast Media) textured or HA-coated • Double-lead “V” threads for 2X faster insertion & quadruple-lead threads near top for increased thread engagement & reduced stress • 2mm extender retained by cover screw for use as a healing collar for one stage surgery • Two self-tapping grooves, extending halfway up implant 5.7mmD Platform...

Open the catalog to page 8
Legacy - 9

LegacyTM1: Two-Piece Implant for Two-Stage Surgery SBM and HA Surface Implants Includes Cover Screw, Extender & Carrier/Transfer

Open the catalog to page 9
Legacy - 10

LegacyTM2 LegacyTM2 Implant System Features & Benefits • Internal connection with 1.5mm long hex & internal lead-in bevel • Body is straight for top 1/3rd with bottom 2/3rds tapered for bone expansion. Surgically compatible with Tapered Screw-Vent® drills (except the 5.7mmD Implant uses 5.4/4.8mmD Step Drill) • Surface options: SBM (Soluble Blast Media) textured or HA-coated • Double-lead buttress threads for improved insertion & quadruple-lead threads near top for increased thread engagement & reduced stress • 2mm extender retained by cover screw for use as a healing collar for one stage...

Open the catalog to page 10
Legacy - 11

LegacyTM2: Two-Piece Implant for Two-Stage Surgery SBM and HA Surface Implants Includes Cover Screw, Extender & Carrier/Transfer Extender NOT supplied with 6mmL implant

Open the catalog to page 11
Legacy - 12

LegacyTM3 LegacyTM3 Implant System Features & Benefits • Internal connection with 1.5mm long hex & internal lead-in bevel • Tapered body allows insertion using Tapered Screw-Vent® drills for 3.7mmD, 4.2mmD & 4.7mmD implants only • Surface options: SBM (Soluble Blast Media) textured or HA-coated • Double-lead buttress threads for improved insertion & initial stability, quadruple-lead threads near top for increased thread engagement & reduced stress • 2mm extender retained by cover screw for use as a healing collar or for one or two-stage surgery • Color-coded carrier usable as a closed-tray...

Open the catalog to page 12
Legacy - 13

LegacyTM3: Two-Piece Implant for Two-Stage Surgery SBM and HA Surface Implants Includes Cover Screw, Extender & Carrier/Transfer Extender NOT supplied with 6mmL implant

Open the catalog to page 13
Legacy - 14

LegacyTM4 LegacyTM4 Implant System Features & Benefits • Revolutionary new, two-piece fixture-mount. Top includes torque-safety feature and detaches in impression for metalto-metal transfer accuracy • Fixture-mount may be shortened at the line to function as a final preparable abutment • 2mm extender retained by cover screw for use as a healing collar for one-stage surgery features a concave transgingival profile which matches the fixture-mount • Internal connection with 1.5mm long hex & internal lead-in bevel • Body is straight for top 1/3rd with bottom 2/3rds tapered for bone expansion....

Open the catalog to page 14