Easy. Safe. Versatile. Test lungs from IMT Analytics are an easy and cost-effective way to reliably test the function and precision of ventilators and anaesthesia machines. Thanks to their adaptability they are ideal for using as part of training to simulate different types of ventilation. For example, they can be used to simulate inadequate application of volume due to unexpected leakages, or to test the accuracy of a ventilator for premature infants. The use of IMT Analytics test lungs prepares nursing personnel and ventilation specialists for every type of critical situation even during their...
Open the catalog to page 2Using the new SmartLung 2000, you can test whether a ventilator meets the requirements of the following standards: IEC 60601-2-12, IEC 60601-2-13 and EN 794-3. • Applicable volume from 0 to 1000 mL • Testing according to IEC standards (ventilators and anaesthesia machines) • The only test lung on the market that covers all the necessary test points • Outstanding features for patient simulations in ventilator training Together with the SmartLung Adult, you can carry out a functional check for a ventilator across all standards. The SmartLung 2000 is the same size as conventional test lungs but...
Open the catalog to page 3SmartLung Infant simulates the lungs of young children while offering the same performance as its sister product, the SmartLung Adult. • Applicable volume from 0 to 200 mL • The lung parameters resistance, compliance and leakage can be set to different levels • Extremely handy and user friendly SmartLung, the smart and cost-effective way to reliably test the function and precision of ventilators and anaesthesia machines. EasyLung - The simple test lung for short routine tests. • Volume cannot be adjusted • Parts made from robust materials, autoclavable at 134 ° C • Practical double taper connection...
Open the catalog to page 4EasyLung Neonatal EasyLung Neonatal is the ideal test lung for checking neonatal ventilators. Key Benefits • 20 mL @ PEEP = 0 mbar; PInsp = 30 mbar • Compliance: 1 mL/mbar @Vt 20 mL • 45 mm × 150 mm • Autoclavable Using the EasyLung Neonatal, you can simulate the exact and sensitive ventilation situation that occurs with very small premature infants, newborns or small children which requires maximum precision when dosing the tidal volume. The benefits of IMT Analytics test lungs • • • • • Exchangeable individual parts Autoclavable High quality Durable material Patented Adjustable resistance Different...
Open the catalog to page 5Summary of the technical specifications SmartLung Adult 2000 SmartLung Adult SmartLung Infant EasyLung Neonatal 25 mL/mbar @ 1 mL/mbar @ Vt = 500 ml, PEEP = Vt = 20 mL 0 mbar Dimensions, L×W×H Additional features Double taper connect