1. Catalogs
  2. Inciner8 Ltd
  3. i8-M200 Large Medical Incinerator

i8-M200 Large Medical Incinerator

i8-M200 Large Medical Incinerator

i8-M200 Large Medical Incinerator

Product catalog summary
Technical Introduction
The i8-M200 incinerator is designed for versatile applications, offering impressive burn rates and batch sizes while being compact enough to fit in a 20ft container. It features a top-loading design for easy access and a secondary chamber with an afterburner for re-burning harmful emissions, making it suitable for medical and pharmaceutical waste disposal.

Features
  • Large top opening for easy waste loading.
  • Efficient waste disposal with patented safety handle.
  • High-quality refractory lining and insulation.
  • CE4 control panel with programmable temperature control.
  • Secondary chamber with 2-second retention time for emission control.
  • Coretex insulation for superior heat retention.
  • Mistral technology for variable airflow and enhanced combustion efficiency.

Technical Breakdown
Incineration converts waste into ash, heat, and flue gas. The process involves a primary chamber for combustion and a secondary chamber for emission control. The i8-M200 features independent temperature control, efficient airflow, and low NOx burners.

Applications
  • Designed for Type I-IV pathological waste, infectious waste, surgical dressings, and more.
  • Compatible with auto loaders for enhanced efficiency.
  • On-site incineration offers a cost-effective waste disposal solution.

Technical Specifications
  • Burn rate: Up to 100Kg per hour.
  • Operational temperature: 850 - 1200°C.
  • Fuel options: Light oil or gas/LPG.
  • Electricity supply: 110v or 230v.
  • Emissions comply with EU standards, featuring low NOx burners.

Ecoflam Burner Specifications
Ecoflam burners provide high efficiency and reliable operation with significant energy savings. They are equipped with low NOx burners to ensure a clean burn cycle.

Average Emissions
  • Sulphur Dioxide: 2.4mg/m3 (limit: 200mg/m3).
  • Total Dust: 12mg/m3 (limit: 30mg/m3).
  • Carbon Monoxide: 78.3mg/m3 (limit: 100mg/m3).
  • Nitrogen Dioxide: 60mg/m3 (limit: 400mg/m3).
See more

Catalog excerpts

i8-M200 Large Medical Incinerator-2

TECHNICAL INTRODUCTION The i8-M200 can be used for a variety of applications, large enough to offer impressive burn rates and batch sizes, while still being small enough to fit in a 20ft container. The i8-M200 features a top-loading design with a large opening for bulky waste items. Like all our ‘M’ range models, it features a secondary chamber with an afterburner for the re-burn of harmful emissions with a 2 second retention time making it ideal for a wide range of medical and pharmaceutical practices. LOAD CAPACITY Inciner8 uses four main size guides within our comprehensive range to differentiate...

 Open the catalog to page 2
i8-M200 Large Medical Incinerator-3

TECHNICAL BREAKDOWN Independent control of primary and secondary temperatures via the control panel. SECONDARY CHAMBER Retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C. CHIMNEY STACK Stainless steel stack for longevity. Fitted with a Velocity Cowl as standard. PRIMARY CHAMBER Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time. SAFE USE HANDLES Easy to open and close loading door. Designed to increase operator safety. COOL TOUCH CLADDING Steel cladding to reduce risk of infection and increase longevity of system....

 Open the catalog to page 3
i8-M200 Large Medical Incinerator-4

TECHNICAL SPECIFICATION OPERATIONAL SPEC PHYSICAL SPEC Combustion Chamber Volume (m3) Fuel Consumption (Ltrs p/hour) Gas retention Time (Seconds) Loading Method Fuel Options Refractory Composition Electricity Supply Operating Footprint Control Panel (IP Rating) Cool Touch Cladding Heat Recovery Viewing Portal Auto Loader Compatible Remote Monitoring Recommended Operational Temperature *The above figures are guidelines ONLY. Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease of installation, maintenance...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.