Technical Introduction
The i8-M40 is a compact medical incinerator designed for small medical facilities. It features a CE2-VFD control panel, tertiary air fan, and updated insulation. The top-loading design ensures liquids are contained during incineration. It includes inbuilt afterburners to eliminate harmful emissions.

Features
  • Cladded for heat retention and hygiene control.
  • Efficient waste disposal with a patented safety handle.
  • High-quality refractory lining and insulation.
  • Programmable temperature control for complete combustion.
  • Secondary chamber with 2-second retention time.
  • Low energy consumption with Coretex insulation and Mistral technology for variable airflow.

Load Capacity and Configuration
The incinerator is top-loading, allowing easy access for trucks and machinery. It can be configured onto trailers or into mobile containerized units for portability.

Technical Breakdown
Incineration converts waste into ash, heat, and flue gas. The process includes a primary and secondary chamber for efficient combustion and emission control. The i8-M40 operates at 850-1200°C to ensure clean emissions.

Applications
Suitable for burning Type I-IV pathological waste, infectious waste, surgical dressings, and more. It is ideal for facilities with limited staff.

Technical Specifications
  • Burn rate: 9-11 kg/hour.
  • Fuel options: Light oil or Gas/LPG.
  • Electricity supply: 110v or 230v.
  • Operating temperature: 850-1200°C.
  • Emission standards: Compliant with EU standards.

Ecoflam Burner Specifications
Features low NOx burners for efficient and clean operation. Emissions are significantly below standard limits, ensuring compliance with environmental regulations.

For more information, contact Inciner8 at +44 (0) 1704 884020 or email [email protected].
See more

Catalog excerpts

i8-M40-2

TECHNICAL INTRODUCTION Our i8-M40 is a compact, simple and effective medical incinerator featuring the enhanced CE2-VFD control panel, tertiary air fan and updated insulation. The top-loading design means liquids are well contained within this system during incineration. The i8-M40 is perfect for small clinics, dental practices or small medical facilities where waste streams are quite low. With the Inbuilt afterburners, the i8-M40 ensures harmful emissions are eradicated with ease. LOAD CAPACITY Inciner8 uses four main size guides within our comprehensive range to differentiate our models, from...

 Open the catalog to page 2
i8-M40-3

TECHNICAL BREAKDOWN Independent control of primary and secondary temperatures via the control panel. SECONDARY CHAMBER Retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C. CHIMNEY STACK Stainless steel stack for longevity. Fitted with a Velocity Cowl as standard. PRIMARY CHAMBER Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time. SAFE USE HANDLES Easy to open and close loading door. Designed to increase operator safety. COOL TOUCH CLADDING Steel cladding to reduce risk of infection and increase longevity of system....

 Open the catalog to page 3
i8-M40-4

TECHNICAL SPECIFICATION OPERATIONAL SPEC PHYSICAL SPEC Combustion Chamber Volume (m3) Fuel Consumption (Ltrs p/hour) Gas retention Time (Seconds) Loading Method Fuel Options Refractory Composition Electricity Supply Operating Footprint Control Panel (IP Rating) Cool Touch Cladding Heat Recovery Viewing Portal Auto Loader Compatible Remote Monitoring Recommended Operational Temperature *The above figures are guidelines ONLY. Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease of installation, maintenance...

 Open the catalog to page 4