1. Catalogs
  2. Inciner8 Ltd
  3. i8-M500 Medical Incinerator

i8-M500 Medical Incinerator

i8-M500  Medical Incinerator

i8-M500 Medical Incinerator

Product catalog summary
Technical Introduction
The i8-M500 is a newly designed incinerator by Inciner8, developed over two years to offer high burn rates and large batch sizes with low emissions. It is suitable for various waste streams due to its excellent liquid retention capabilities.

Features
  • Cladded for heat retention and hygiene control.
  • Efficient medical waste disposal with a patented safety handle.
  • High-quality refractory lining and insulation.
  • CE5 control panel with programmable temperature control.
  • Secondary chamber with a 2-second retention time.
  • Low energy consumption and fast pre-heat capabilities.
  • Coretex insulation for superior heat retention.
  • Mistral technology for variable airflow and increased efficiency.

Load Capacity and Design
  • Top loading design for easy access and compatibility with bin tippers and autoloaders.
  • Constructed from superior grade steel with a unique concave design to prevent cold spots.
  • Hydraulic doors for easy operation.

Technical Breakdown
  • Incineration converts waste into ash, heat, and flue gas, with heat usable for cleaning or heating.
  • Independent control of primary and secondary temperatures.
  • Primary chamber designed for maximum airflow and efficiency.
  • Secondary chamber retains and re-burns exhaust gases at 850°C.

Applications
  • Suitable for Type I-IV pathological waste, infectious waste, surgical dressings, and more.
  • Compatible with auto loaders and designed for simple operation.

Operational Specifications
  • Burn rate: 30-40 kg/h.
  • Combustion chamber volume: 5.00 m3.
  • Fuel options: Light oil or Gas/LPG.
  • Recommended operational temperature: 850-1200°C.

Technical Specifications
  • Secondary combustion chambers operate at 850-1200°C to prevent harmful emissions.
  • Emissions are influenced by waste materials; pollution control methods should be selected accordingly.
  • Ecoflam burners provide high efficiency and low NOx emissions.

Average Emissions / EU Standards
  • Sulphur Dioxide: 2.4 mg/m3 (limit: 200 mg/m3).
  • Total Dust: 12 mg/m3 (limit: 30 mg/m3).
  • Carbon Monoxide: 78.3 mg/m3 (limit: 100 mg/m3).
  • Nitrogen Dioxide: 60 mg/m3 (limit: 400 mg/m3).
See more

Catalog excerpts

i8-M500  Medical Incinerator-2

TECHNICAL INTRODUCTION One of our newest designs the i8-M500 uses our proven technlogy and features normally found on our largest machines. Taking over two years to develop the i8-M500 was designed from the ground up to offer impressive burn rates and large batch sizes while still achieving some of the lowest emissions in its class. This design also provides excellent liquid retention making this incinerator ideal for the incineration of many different waste streams. The i8-M500 price and size has made it a popular choice. LOAD CAPACITY Inciner8 uses four main size guides within our comprehensive...

 Open the catalog to page 2
i8-M500  Medical Incinerator-3

TECHNICAL BREAKDOWN Independent control of primary and secondary temperatures via the control panel. SECONDARY CHAMBER Retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C. CHIMNEY STACK Stainless steel stack for longevity. Fitted with a Velocity Cowl as standard. PRIMARY CHAMBER Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time. SAFE USE HANDLES Easy to open and close loading door. Designed to increase operator safety. COOL TOUCH CLADDING Steel cladding to reduce risk of infection and increase longevity of system....

 Open the catalog to page 3
i8-M500  Medical Incinerator-4

TECHNICAL SPECIFICATION OPERATIONAL SPEC PHYSICAL SPEC Combustion Chamber Volume (m3) Fuel Consumption (Ltrs p/hour) Gas retention Time (Seconds) Loading Method Fuel Options Refractory Composition Electricity Supply Operating Footprint Control Panel (IP Rating) Cool Touch Cladding Heat Recovery Viewing Portal Auto Loader Compatible Remote Monitoring Recommended Operational Temperature *The above figures are guidelines ONLY. Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease of installation, maintenance...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.