Overview of Over Bench Fume Hoods
The document provides an overview of three models of Over Bench Fume Hoods: Cairo, VWS, and PMMA. These models are designed for use with a bench and are simpler than previous models, lacking user-specific service adaptations.

Standards Compliance
The fume hoods comply with several standards, including EN 14175-1, EN 14175-2, EN 14175-3, EN 13150, EN 61010-1, and EN 61326-1. They also have CE marking according to directives 2014/30/EU and 2014/35/EU.

Model Specifications
  • Cairo: Designed for high-risk lab work, featuring a steel exterior with epoxy-polyester coating and a simple CAV system, upgradeable to VAV.
  • VWS: Suitable for small lab work, made entirely of steel with a removable work surface and basic ON/OFF controls.
  • PMMA: Known as an acrylic fume hood, designed for small lab work with a structural body and integrated electrical outlets.

Technical Specifications
The document details dimensions, airflow specifications, and electrical information for each model, including frequency, power supply voltage, and installed power.

Safety and Installation
The ENS Fume Hood is class I equipment, requiring earthing of all metal parts and includes magnetothermic protections. A circuit-breaker is necessary at the installation site.

Detailed Model Descriptions
  • Cairo Fume Hood: Features cold rolled sheet metal construction, phenolic compact interior, and options for VAV system and automatic sash closing.
  • PMMA Fume Hood: Constructed with cold rolled steel, stainless steel surface, and polymethyl methacrylate or glass sides and window.
  • VWS Fume Hood: Entirely made of cold rolled steel with a glazed window, simple and versatile.

Technical Specifications
Dimensions and materials for each model are specified, including steel sheet, phenolic compact, stainless steel, polymethyl methacrylate, glass, and technical ceramic.

Contact Information
Contact details for Industrial Laborum's headquarters, commercial delegation, and manufacturing facilities in Portugal are provided.
See more

Catalog excerpts

BENCH FUME HOOD-1

BENCH FUME HOOD HOTTE DE BANCADA SORBONNE SOUR LE PAILLASSE

 Open the catalog to page 1
BENCH FUME HOOD-2

OVER BENCH FUME HOODS HOTTES PARA BANCADA SORBONNES SUR LES PAILLASSES OVER BENCH SOBRE BANCADA The range of Over Bench Fume Hoods is divided into three distinct models, the Cairo, the VWS and the PMMA Fume Hood, each of them has differentiating characteristics, sharing only the fact that they need a bench. Moreover, the materials, design and purpose differ that allows a more complete line, however these are simpler than the lines previously presented, not presenting, for example, the ability to adapt to the services that the user may need . A linha de hottes sobre bancada está divida em três...

 Open the catalog to page 2
BENCH FUME HOOD-3

CAIRO/VWS/PMMA FUME HOODS Cairo - Fume Hood designed for lab work that poses a high risk to users, is a fume hood consisting of two distinct parts, extirior body and inner lining. The exterior body serves as a support for the inner lining, is made of steel sheet powder coated with epoxy-polyester resins. It also supports the services that will be located on the sides. The inner linning is the part in direct contact with the chemical vapors, it is made of laminated compact. The standard model is supplied without any service, and is only supplied with a simple control CAV system, (Constant Air...

 Open the catalog to page 3
BENCH FUME HOOD-4

TECHNICAL SPECIFICATIONS ESPECIFICAÇOES TÉCNICAS SPÉCIFICATIONS TECHNIQUES Dimensões Dimensions *Other dimensions are possible upon request *Outras dimensões são possíveis mediante solicitação *D'autres dimensions sont possibles sur demande The Cairo Fume Hood comes with constant air volume (CAV), however can be equipped with VAV system (variable air volume), which improves the performance of the Fume Hood as well as its overall energy consumption. In the same way the Fume Hood can also be equipped with automatic window closing system. The PMMA and VWS fume hoods only have an ON/OFF button for...

 Open the catalog to page 4
BENCH FUME HOOD-5

TECHNICAL SPECIFICATIONS ESPECIFICAÇOES TÉCNICAS SPÉCIFICATIONS TECHNIQUES Services pre-installation Electrical information Pré-instalação de serviços Pré-installation des services Informação eléctrica Informations électriques The installation site must have a circuit-breaker to ensure that in the case of other equipment connected to the circuit-breaker, these shall not be without power in case of maintenance of the Fume Hood. model size tamanho do modelo taille du modèle Power Supply Voltage Tensão de alimentação Tension d'alimentation V A hotte de química modelo ENS é um equipamento de classe...

 Open the catalog to page 5
BENCH FUME HOOD-6

MATERIAIS E CODIFICAÇÃO MATÉRIEL ET CODIFICATION STEEL SHEET COMPACTO FENÓLICO PHENOLIC COMPACT CHAPA DE AÇO TÔLE D'ACIER Cairo fume hood with glazed laterals Hotte Cairo com laterais envidraçadas Sorbonne Cairo avec des côtés vitrés COMPACT LAMINATE COMPACTO FENÓLICO PHENOLIC COMPACT CHAPA DE AÇO TÔLE D'ACIER STEEL SHEET STAINLESS STEEL POLYMETHYL METHACRYLATE POLYMETHYL METHACRYLATE AÇO INOX ACIER INOXYDABLE POLIMETIL METACRILATO POLIMETIL METACRILATO POLYMÉTHACRYLATE DE MÉTHYLE POLYMÉTHACRYLATE DE MÉTHYLE CHAPA DE AÇO TÔLE D'ACIER TECHNICAL CERAMIC GRÉS CERÂMICO CÉRAMIQUE TECHNIQUE VIDRO VERRE...

 Open the catalog to page 6
BENCH FUME HOOD-7

sede Rua Alfredo Cunha, nº155, Loja 34 4450-023 Matosinhos Portugal instalações fabris Sobreiro Torto, Branca - Apt. 187 3854-909 Albergaria-a-Velha Portugal T +351 234 529 500 F +351 234 525 263 delegação comercial Rua Professor Mernâni Cidade 11b 1600-631 Lisboa , Portu

 Open the catalog to page 7

All Industrial Laborum Iberica catalogs and technical brochures

  1. Storage systems

    36  Pages

  2. Safety cabinet

    16  Pages

  3. COMPANY PROFILE

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.