INFIGROUP specializes in combustion expertise, offering a Waste to Power (WTP) solution that utilizes municipal and industrial waste, including specific wastes like shredded tires, to generate power through a rotary kiln incineration line.
Waste Processing and Combustion
All collected waste is stored in transition silos, ground, and pre-dried. Liquid waste is injected into the combustion chamber automatically. The waste is introduced into the combustion chamber via a hopper and a guillotine door to minimize heat loss. The rotary kiln ensures optimal combustion by rotating the waste, which descends by gravity into the ash removal system.
Post-Combustion and Ash Handling
Post-combustion processes burn remaining particles in the fumes. Ashes, representing 2-3% of the waste weight, are automatically extracted and can be recycled in civil works. The quiet chamber ensures fumes remain at 1100°C for at least 2 seconds to meet European standards.
Cooling and Emission Control
The cooling chamber, used if gases exceed 900°C, precedes the heat exchanger, which lowers smoke temperatures to around 100°C. This is crucial for the subsequent injection of lime and activated carbon in the dilution reactor to neutralize acids and absorb toxins. The filtration system uses ceramic candle filters to capture harmful fumes and dust.
Organic Rankine Cycle (ORC)
The ORC replaces water with an organic fluid with a lower boiling point. This fluid is vaporized, driving a turbine to generate electricity. The cycle is closed, ensuring no fluid consumption.
Infrastructure and Controls
The system includes a chimney, typically 20 meters high, and an exhaust fan to manage fumes. Controls are managed via a console for clear oversight of all cycles, ensuring efficient operation.
See more

Catalog excerpts

POWER PRODUCTION-1

565, Avenue du Prado 13008 Marseille France POWER PRODUCTION A ROTARY KILN INCINERATION LINE - Operating process of our WTP (Waste to Power) solution, a power plant operating with municipal waste and miscellaneous waste All types of wastes can be used, MSW or any other industrial waste, including specific wastes such as shredded tires, up to 25% of the total waste. All the collected waste is stored in transition silos. This waste is then subjected to a grinding operation with separation of the liquids, then it is eventually pre-dried. Liquid waste is injected into the combustion chamber using injectors for liquids (liquid, muddy, or pasty waste), which, like for solid waste, is done fully automatically after an operator has triggered loading, intrinsically safely. INFIGROUP, COMBUSTION EXPERTISE

 Open the catalog to page 1
POWER PRODUCTION-2

THE CONTROLS The controls are made on a console which is installed near the machine, which allows a very clear vision of all stages of the different cycles. After starting up and heating the incinerator, all the machine cycles are then concurrent, i.e. all the cycles are in action, namely: Taking over of the skips filled with waste at a specific location, the incinerator, by hydraulic assistance, transports these skips and empty them. This other cycle burns dust and other large particles inside the fumes. Burners are installed on this Post-Combustion to ensure proper operation and maximum elimination...

 Open the catalog to page 2
POWER PRODUCTION-3

- Heat Exchanger With a robust design, this element has an important role for the following cycles. The heat exchanger has the role of lowering the smoke temperatures (depending on the kind of the waste) from 900°C-1000°C to around 100°C. If these temperatures at the outlet of the cooling chambers were not lowered, the following cycles which are the injection of lime and activated carbon into a dilution reactor, and above all the filtration system would be highly disturbed and damaged. These cycles which ensure emissions with a minimum of pollutants would be totally ineffective. The heat exchanger...

 Open the catalog to page 3
POWER PRODUCTION-4

- The dilution reactor The injection of hydrated lime to neutralize acids (HCL, SO2, HF) and the injection of activated carbon to absorb furans and dioxins (2 separate hoppers are provided for this purpose) are used to capture the residues in the fumes and to weigh them down. Located between the heat exchanger that cools the fumes and the filtration system that filters the same fumes, the reactor is made up of piping for transporting and above all reducing the temperatures of the treated fumes to the filtration system. This processing is compulsory. The size of this reactor is also proportional...

 Open the catalog to page 4

All INFIGROUP catalogs and technical brochures

  1. HDI RANGE

    4  Pages

  2. LCI RANGE

    4  Pages

  3. FRI RANGE

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.