Catalog excerpts

Operating and Treatment Lights NEXUS OL-01/OL-02 PROXY OL-03 ONYX TL-01
Open the catalog to page 1
NEXUS, PROXY and ONYXOperating and Treatment Lights Operating light head Operating lights INFIMED NEXUS and PROXY and Fiow-optimised Hght head treatment lights INFIMED ONYX with LED light source are distinguished by innovative technology and modern design. The little weight, ergonomic light heads as well as comfortable handles enable easy and precise set up and positioning of the operating light during surgery. Waterproof, resistant to environmental factors design and smooth surfaces guarantees ease of disinfection and maintenance for perfect hygiene. Ergonomic shape of the light...
Open the catalog to page 2
Backside view Backside view Side view Environmental Protection Halogen Lamps Discharge Lamps Low power consumption and high efficiency of LED light sources, provide measurable economic benefits by reducing maintenance costs of the operating theater. Long lifetime of LED technology light sources, estimated at over 50,000 hours, several times exceeds conventional light sources. There is no frequent replacement of the light sources, significantly reducing maintenance and replacement costs. LED light sources do not contain any heavy metals like lead or mercury which facilitate their future...
Open the catalog to page 3
NEXUS, PROXY and ONYX Operating and Treatment Lights Operating light head Efficiency LED technology ensures consistent light distribution and enables almost shadow-free conditions. Low heat radiation minimize the temperature increase in the surgeon’s head area to imperceptible level. High light intensity and color rendering index facilities surgeries of especially narrow and deep wounds. The illumination is electronically dimmed to provide optimum illumination of operating field. Together with wide range of operating field size adjustment optimal visual conditions are ensured. Colour...
Open the catalog to page 4
additional options Values are subject to a general industry tolerance of +/- 3%
Open the catalog to page 5
NEXUS, PROXY and ONYX Operating and Treatment Lights Configurations Operating lights INFIMED are available in ceiling suspensions (single, double, triple), single wall suspension and the mobile version equipped with the battery. Examples of suspension configurations for operating lights: Single ceiling suspension Single wall suspension Mobile base Triple ceiling suspension, two arms n<360°, one arm nx360°
Open the catalog to page 6
Double ceiling suspension nx360° Double ceiling suspension “T-type” n<360° Double ceiling suspension for low height rooms nx360
Open the catalog to page 7
Operating Lights OL-01 / OL-02 LCD Touch control panel (option) Optionally, sterile, plastic, autoclavable control handle can be used to adjust light insentity, light field size and color temperature Addional functions The sensor type control panel (standard) enables adjustment of: - illumination intensity - endoscopic illumination intensity - switching ON/OFF - light field size (option) - color temperature adjustment (option) Measurement of the distance from operating area The sensor in the light recognises the distance from the operating field and adjust the illumination intensity...
Open the catalog to page 8
Camera Integrated video system Operating lights NEXUS OL-01 and OL-02 can be equipped with video camera, fixed in the center of the light. Optionally the lights can be delivered with standard sterile, plastic handle, to be exchanged into handle with camera in the future. Sony camera, Full 1920 x 1080/30p High Definition, adjustable from keyboard.
Open the catalog to page 9
NEXUSOperating Lights BLINDS AIR CONDITIONING / TEMPERATURE /UGHT/ HUMIDITY VIDEO RECORDER Opera control system Provides better and easier control of the devices in the operating room from a single location. The system is very flexible, open, modular, can be adjusted to comply the client's expectations and requirements, accordingly to the above shown solutions. Can be operated from wall mounted control panel or wirelessly from mobile device. The product is safe and secure and it is a certified Class I Medical Device manufactured in accordance with the ISO 9001, 13485 and other...
Open the catalog to page 10
ROOM CAMERAS PHONE/VOIP/ SPEECH RECOGNITION
Open the catalog to page 11
Operating Lights OL-03 / Operating light head Operating light PROXY Is the economical solution of the modern operating light. The light head ensures perfect light parameters and full functionality, providing adjustments of light intensity, light field diameter and color temperature. Nevertheless it is delivered only in one version, without any options and modifications. The light head cannot be equipped with the video camera fixed in the center, however can be provided seperately on additional arm. Neither the light cannot be controlled via OPERA control system. All configurations mentioned...
Open the catalog to page 12
OL-03 / Backside view Parameter of operating light INFIMED PROXY additional options Values are subject to a general industry tolerance of +/- 5%
Open the catalog to page 13
Minor operating and treatment Lights Treatment light ONYX, 60 000 lx Lights INFIMED ONYX TL-01 Lights ONYX are usually used in operating and procedures rooms, intensive care, neonatology units, induction rooms, dentist, dermatology, gynecology cabinets, veterinary cabinets, dissection rooms. They are available with different levels of illumination intensity. Treatment lights can have 30 000 or 60 000 lx. The light having 100 000 lx, optionally with field size adjustment can be used as minor operating light. Light intensity and optional light field size adjustment are adjustable by control...
Open the catalog to page 14
Minor operating light ONYX, 100 000 lx with field size adjustment. Treatment light ONYX, 30 000 lx Parameter additional options Values are subject to a general industry tolerance of +/- 5%
Open the catalog to page 15
European Funds Smart Growth European Union European Regional Development Fund Polska For special requirement of the customer it is possible to produce the product with changed technical parameters which do not diminish its safety. The details given in this catalogue are correct at the time of going to press. Infimed Sp. z o.o., however, reserves the right to improve shown equipment. V_) INFIMED Sp. z o.o. adres ul. Kabaty 1, 34-300 Zywiec, Polska tel/fax +48 33 861 40 96 email office@infimed.pl www www.infimed.pl Sqd Rejonowy w Bielsku-Biafej, VIII Wydziaf Gospodarczy Krajowego Rejestru...
Open the catalog to page 16All Infimed catalogs and technical brochures
-
OPERA control system
8 Pages
-
Modular operating theathres
20 Pages
-
Operating table
16 Pages