Automatic / manual dosing and Nitric Oxide monitor
4Pages

{{requestButtons}}

Catalog excerpts

Automatic / manual dosing and Nitric Oxide monitor - 1

NOXtec 1000 Automatic or manual dosing and Nitric Oxide Monitor 01NXTC1000 NOXtec 1000 is a medical device which both dosifies and monitors the supply of nitric oxide (NO). NO is a gaseous vasodilator used to treat pulmonary arterial hypertension. It is supplied to the patients mixed with medical oxygen. NOXtec 1000 supplies a stable dosis throughout the therapy, even triggering an automatic exchange of the cylinders (it can harbor two cylinders) if needed. NOXtec calculates automatically the necessary dosing flow, thanks to a breathing flow sensor applied to the patient’s circuit. Alternatively, the dosing flow can be set manually. Thanks to the continuous sampling of the NO-O2 mixture flow supplied, NOXtec is able to monitorize the NO concentration that the patient is receiving, and to check if this value is placed within predetermined thresholds. NOXtec 1000 also monitors trace quantities of nitrous oxide (NO2) in the mixture, a highly toxic gas which can compromise the patient’s safety during the treatment. NOXtec 1000 triggers and alarm when this trace surpasses a threshold value. MAIN FEATURES - Dosing and monitoring modules and user interface independent from each other to guarantee the patient’s safety. - Automatic cylinder exchange to increase the treatment autonomy and optimize the gas consumption. - Automatic venting procedure to minimize the NO2 supplied to the patient at the beginning of the treatment and during the cylinder exchange, and also to depressurize the system when the device is not in use. - Automatic calibration of the NO, NO2 and O2 sensors. - NOXtec includes a manual dosing mode, which can be used even when the device is off. - Negligible liberation of NO to the environment. The device includes a purge outlet to gather and canalize the residual gas. - Hot wire and differential pressure technologies for the external breathing flow sensors. - Ethernet port for remote technical assistance. - USB port to retrieve therapy data files. C/ Tungsteno 11-15. Arganda del Rey, 28500, Madrid Tel.: +34 91 871 99 50 www.itcsal.comitcsal@itcsal.com 07/2018-Re

Open the catalog to page 1
Automatic / manual dosing and Nitric Oxide monitor - 2

NOXtec 1000 Automatic or manual dosing and Nitric Oxide Monitor 01NXTC1000 Reference Description Qty NOXtec 1000: Nitric Oxide Monitor with Automatic Deliver System ■ Main box with pneumatic, electronic and user interface. Manifold with calibration gas sensors: NO, NO2 and O2, including PCB battery power Flow sensor cable Main cable "xx" Stainless steel gas regulator for NO supply, with high pressure sensor incorporated. Reference Description Qty 11MMBU0x00_IX Stainless steel gas regulator for NOXtec gas calibration. 1 01NTMNPG19 NOXtec gas calibration cylinder 5L...

Open the catalog to page 2
Automatic / manual dosing and Nitric Oxide monitor - 3

Differential pressure Hot wire NOXtec 1000 Automatic or manual dosing and Nitric Oxide Monitor 01NXTC1000 TECHNICAL SPECIFICATIONS PHYSICAL SPECIFICATIONS Dimensions and weight: - Main unit: 205 x 300 x 345 mm; 9.2 kg - Cart: 1250 x 670 x 640 mm; 47.5 kg Cart's capacity for cylinders: 2 cylinders of 20L Materials: AISI 304 and AISI 316 L stainless steel, PTFE and ABS Screen: Touch colour 10.1" LCD screen DOSING MODULE Dosing modes: ■ Real time ■ Automatic ■ Semiautomatic ■ Manual Measuring range: - NO flow: 0-4 L/min NO dosing interval: 0-100 ppm (upgradeable upon request) Dosing...

Open the catalog to page 3
Automatic / manual dosing and Nitric Oxide monitor - 4

NOXtec 1000 Automatic or manual dosing and Nitric Oxide Monitor 01NXTC1000 OPERATING AND STORAGE CONDITIONS - Operating conditions: 10-40C; 15-90% humidity - Storage conditions: -10-60C; 15-90% humidity ELECTRICAL SPECIFICATIONS Power: 100-240 VAC, 50-60 Hz Battery: - Duration: 4h - Charging time: 2.5h approx. Normative: - EN 60601-2:2007 + CORR: 2010 / IEC 60601-1-2: 2007 - EN 60601-1: 2006 + CORR:2010 + A11: 2011 + A1: 2013 + AC: 2014 + A12: 2014 / IEC 60601-1: 2005 + CORR: 2006 + CORR2: 2008 + A1:2012 Classification: Class I, Type B ELECTROMAGNETIC AND RF SPECIFICATIONS Guidance and...

Open the catalog to page 4