Regulators and Flowmeters
29Pages

{{requestButtons}}

Catalog excerpts

Regulators and Flowmeters - 3

JUST FLOW F - Series Ball flowmeters Ref.: See table JUST FLOW F Series flowmeters can be used in medical facilities with an available gas piped network. • Available for oxygen and medical air (consult our staff for other gases). • Scales of 4, 6 or 15 l/min, twistable 360° to facilitate its reading. • Available with a humidifier bottle, selector-bearing direct outlet. By turning a small side handle or a revolver system, the selector diverts the flow of the humidifier to a tube spigot. • It can be provided individually or on a dual version, and it can be mounted either with a direct...

Open the catalog to page 3
Regulators and Flowmeters - 4

JUST FLOW F - Series Ball flowmeters Ref.: See tableReferences for flow range 0 to 15 l/min Standards JUST FLOW F + Connector JUST FLOW F Double output + Connector JUST FLOW F Double mounting JUST FLOW F Double mounting - Double output JUST FLOW F Rail - Knob clamp JUST FLOW F Rail - Pushbutton clamp JUST FLOW F Rail - Double output - Knob clamp JUST FLOW F Rail - Double output - Pushbutton clamp JUST FLOW F Rail - Double mounting - Knob clamp JUST FLOW F Rail - Double mounting - Pushbutton clamp JUST FLOW F Rail - Double mounting - Double output -Knob clamp JUST FLOW F Rail - Double...

Open the catalog to page 4
Regulators and Flowmeters - 5

JUST FLOW C - Series Dial flowmeters Ref.: See table JUST FLOW C Series flowmeters can be used in medical facilities with an available gas piped network. • Turning the top control button the operator can select the flow that will be supplied by its inferior connection. This selection appears in the front display. Models available for oxygen and medical air with 4, 8, 15, 25 or 50 l/min top range. • Models available with a direct outlet to a humidifier bottle and with a flow selector which, turning a little front handle, diverts the humidifier flow towards a front nozzle for flexible...

Open the catalog to page 5
Regulators and Flowmeters - 6

JUST FLOW C - Series Dial flowmeters Ref.: See tableReferences for flow range from 0 to 15 l/min Standars Type C/ Tungsteno 11-15. Arganda del Rey, 28500, Madrid Telf.: +34 91 871 99 50 www.itcsal.com itcsal@itcsal. com

Open the catalog to page 6
Regulators and Flowmeters - 7

JUST FLOW C - Series Dial flowmeter with stabilized pressure Ref.: See table The flowmeter JUST FLOW C Series can be used in medical facilities with an available gas piped network and is especially designed to stabilize the possible differences of pressure in the supply, thanks to a previous regulation step.  Turning the top control button the operator can select the flow that will be supplied by its inferior connection. This selection appears in the front display. Models for oxygen and medical air with top range in 1, 4, or 15 l/min. Models available with a direct outlet to a humidifier...

Open the catalog to page 7
Regulators and Flowmeters - 8

JUST FLOW C - Series Dial flowmeter with stabilized pressure Ref.: See tableReferences for flow range 0 to 15 l/min Standards Type C/ Tungsteno 11-15. Arganda del Rey, 28500, Madrid Telf.: +34 91 871 99 50 www.itcsal.com itcsal@itcsal. com

Open the catalog to page 8
Regulators and Flowmeters - 9

JUST VAC Series Vacuum regulators HV Ref.: See table The high vacuum regulator JUST VAC provides regulation of continuous suction for its use in tracheal and pharyngeal ways during surgical procedures and continuous gastric drainage.  The vacuum regulator provides suction from 0 to total suction.  They are classified as High Vacuum / High Flow.  For the safety of the patient, in case of accidental connection to a positive gas pressure, the regulators can be equipped with an optional positive pressure relief valve.  JUST VAC incorporates an ON-OFF dispositive, through which the...

Open the catalog to page 9
Regulators and Flowmeters - 10

JUST VAC Series Vacuum regulators HV Ref.: See table References JUST VAC HV + Connector JUST VAC HV double mounting + Connector JUST VAC HV to rail - Knob clamp JUST VAC HV to rail double mounting - Knob clamp JUST VAC HV with 038,0 tube flange JUST VAC HV with 038,0 tube flange double mounting 1 Other outputs replace E (disposable filter) with: D (DISS output), T (filter with safety overflow trap), F (bottle of 0,51), M (Metallic nipple) or 0 (free output). 2 Other rail mounting replace P (knob clamp) with: G (pushbutton clamp), R (wallplate) or H (bearing plate) 3 For other gases please...

Open the catalog to page 10
Regulators and Flowmeters - 11

JUST VAC Series Vacuum regulators HV with BackPack Ref.: See table The High Vacuum regulator JUST VAC HV Backpack allows the operator to regulate the continuous suction of tracheal and pharyngeal secretions during surgical procedures and continuous nasogastric drainage. The vacuum regulator incorporates a Venturi-effect system, which allows suction through a connection to oxygen or medical air outlets in facilities with no piped Vacuum network. • The vacuum regulator provides suction from 0 to 450 mmHg. • They include the PUSH system for a quick and easy replacement of filters and...

Open the catalog to page 11
Regulators and Flowmeters - 12

JUST VAC Series Vacuum regulators HV with BackPack Ref.: See table References JUST VAC HV Backpack + Connector 11ASVP8XDS 11ASVP8XNS JUST VAC HV Backpack to rail - Knob clamp 13ASVP6XDS 13ASVP6XNS JUST VAC HV Backpack to rail - Pushbutton clamp 13ASVP9XDS 13ASVP9XNS JUST VAC HV Backpack with 038 flange + Connector 14ASVP8XDS 14ASVP8XNS For other outputs replace S (disposable filter) with: D (DISS output), R (Metallic connector for flexible hose) or P (tube-fitting compressed nipple). For other gases please consult the standards. Consult our staff for other models. C/...

Open the catalog to page 12
Regulators and Flowmeters - 13

SUCTION UNITSContinuous / Intermittent Vacuum Regulators Ref.: See table The intermittent suction unit is a combination of continuous and intermittent vacuum regulators to use in centralized vacuum systems in hospitals. • It combines the versatility of an intermittent mode for the nasogastric drainage and a continuous mode for tracheal, pharyngeal or surgical suction. • It incorporates a REG-OFF-INT device that allows the operator to interrupt aspiration without closing the suction control valve. • In the intermittent mode, this unit employs a pneumatic logic module to alternate between the...

Open the catalog to page 13
Regulators and Flowmeters - 14

Standards DIN 13260 NF S 90-116 BS 5682 Type JUST VAC CI Analogical + Connector llVP^EDIM llVP^EIMF JUST VAC CI Paediatric Analogical + Connector 11VP|PAEDN 11VP|PAENF JUST VAC CI Analogical to rail - Knob clamp 13VP|AAEPN JUST VAC CI Paediatric Analogical to rail - Knob clamp 13VPIPAEPD 13VPIPAEPN JUST VAC CI Analogical with 038,0 tube flange 14VPIAAEPD 14VPIAAEPN JUST VAC CI Paediatric Analogical with 038,0 tube flange 14VPIPAEPD 14VPIPAEPN For other outputs replace E (filter) with: D (DISS output), T (filter with safety overflow trap), F (bottle of...

Open the catalog to page 14

All Ingeniería y Técnicas Clínicas catalogs and technical brochures

  1. Rail Systems

    49 Pages

  2. 11MRBX81S4

    1 Pages

  3. 09MTRM0000

    1 Pages

  4. 11MOBX81S4

    1 Pages

  5. 09MCRU0000

    2 Pages

  6. REANIVAC I

    1 Pages

  7. 13ACCS2C00

    1 Pages