Introduction to Inion CPS™ Implants
Inion CPS™ implants are bioabsorbable devices used in craniomaxillofacial (CMF) surgery, made from a blend of polymers with a history of safe clinical use. They support natural healing by providing initial stability and gradually transferring load to the bone as they degrade.

Material and Degradation Characteristics
The implants degrade in vivo by hydrolysis, metabolizing into CO2 and water. They maintain at least 70% of initial strength for a specified period (6 weeks for pediatric implants and 9 weeks for others), with complete bioresorption within two to four years.

Advantages of Inion CPS™ Implants
  • Bioabsorbable, eliminating the need for permanent metal implants.
  • Reduced risk of growth restriction in children.
  • Predictable degradation aids bone regeneration.
  • No interference with postoperative imaging.
  • Supplied sterile and single-packed to prevent cross-infection.
  • Easy anatomical contouring after heating in the Inion Thermo™ water bath.

System Components and Applications
The system includes plates, screws, and meshes for various CMF applications, suitable for both pediatric and adult patients, and is the only bioabsorbable system for all facial skeleton areas.

Clinical Use and Evidence
Used in over 120,000 operations since 2001, Inion CPS™ implants offer a comprehensive alternative to titanium systems, reducing the need for removal surgeries and associated trauma and costs.

Innovative Design Features
  • Scalloped plate design for optimized strength.
  • Malleable plates after heating for precise adaptation.
  • Versatile screw insertion methods, including manual tap and self-drilling options.
  • Universal screwdriver blade for all screw sizes.

Product Range
The document details various systems (1.5 mm, 2.0 mm, 2.5 mm) with specific plates and screws for different surgical needs, including pediatric craniofacial procedures and mandibular fixation.

Instruments and Accessories
A range of instruments is available for use with the systems, including drill bits, bone taps, and countersinks, along with universal instruments like screwdriver blades and plate bending pliers.

Research and References
The document cites numerous studies and clinical trials supporting the efficacy and safety of Inion CPS™ implants in various surgical applications.
See more

Catalog excerpts

Inion CPS™ - Bioabsorbable Fixation System-2

Material advantage What are the Inion® bioabsorbable implants made from? The degradation profile Inion® bioabsorbable polymers are amorphous, degrade All Inion CPS™ implants are based on Inion® in vivo by hydrolysis and are metabolised by the body bioabsorbable polymer blends and have excellent into CO2 and water. The degradation profiles have been handling properties, and strength and degradation tailored to provide initial stability and then progressively characteristics that support a more natural healing transfer the load to bone to aid bone regeneration. Mass loss occurs thereafter. The...

 Open the catalog to page 2
Inion CPS™ - Bioabsorbable Fixation System-3

Inion CPS™ - a complete system for CMF fixation 1.5 mm CPS BABY SYSTEM For paediatric craniofacial procedures (similar use to titanium 1.0 - 1.2 mm) Strength retention is minimum 6 weeks 1.5 mm CPS SYSTEM For cranial and midface fixation (similar use to titanium 1.0 - 1.2 mm) Strength retention is minimum 9 weeks Inion CPS™ systems 2.0 mm CPS SYSTEM For midface, mandibular and orthognathic fixation (similar use to titanium 1.5 - 1.7 mm) Strength retention is minimum 9 weeks 2.5 mm CPS SYSTEM For mandibular fixation (similar use to titanium 2.0 - 2.4 mm) Strength retention is minimum 9 weeks**...

 Open the catalog to page 3
Inion CPS™ - Bioabsorbable Fixation System-4

Innovative plate design Scalloped plate design Optimised strength / material ratio Minimised screw hole deformation during bending Handling advantage Low plate / screw profile for reduced palpability Plates are malleable after activation in the Inion Thermo™ water bath (55°C). After water bath treatment, plates are most malleable for 10-15 seconds for easy adaptation to the bone. They can also be re-heated up to three times for further contouring. Maximum heating time is 30 minutes.

 Open the catalog to page 4
Inion CPS™ - Bioabsorbable Fixation System-5

Versatile screw insertion methods Fast and easy to use techniques ■ Innovative screw solutions Self-drilling bone tap method (self-drilling tap for 1.5 mm and 2.0 mm screws) Fine screw threads provide maximum engagement in cortical bone Self-tapping screws (1.5 / 2.0mm screws thin Monocortical screws are packaged in a convenient screw ring (5 + 1 emergency screw included in 1.5 monocortical applications) Bicortical screws (2.0 / 2.5 / 2.8 mm) are packaged in an easy to use dispenser Universal screwdriver blade used for all Inion CPS™ screw sizes Simple and secure push-fit s

 Open the catalog to page 5
Inion CPS™ - Bioabsorbable Fixation System-7

Inion CPS™ implants Inion CPS™ Baby 1.5 mm System For paediatric procedures, similar use to titanium 1.0-1.2 mm Art. No. 20 hole plate (reinforced centre hole) Mesh plate, 7 x 7 holes Mesh plate, 14 x 14 holes 1.5 x 4 mm Screw Ring 5pcs (+ one 2.0 x 5 mm emerg.) 1.5 x 6 mm Screw Ring 5pcs (+ one 2.0 x 7 mm emerg.) Inion CPS™ 1.5 mm System For cranial and midface fixation, similar use to titanium 1.0-1.2 mm Art. No. 20 hole plate (reinforced centre hole) L-plate, right, 7 holes (on the left) L-plate, left, 7 holes (on the right) Burrhole plate Mesh plate, 7 x 7 holes Mesh plate, 14 x 14 holes...

 Open the catalog to page 7
Inion CPS™ - Bioabsorbable Fixation System-8

Inion CPS™ implants Inion CPS™ 2.0 mm System For midface, mandibular and orthognathic fixation, similar us e to titanium 1.5-1.7 mm Art. No. 4 hole plate, extended Orthognathic 6 hole plate Orthognathic L-plate, right, 7 holes (on the left) Orthognathic L-plate, left, 7 holes (on the right) Mesh plate, 7 x 7 holes 2.0 x 5 mm Screw Ring 5pcs (+ one 2.5 x 6 mm emerg.) 2.0 x 7 mm Screw Ring 5pcs (+ one 2.5 x 8 mm emerg.)

 Open the catalog to page 8
Inion CPS™ - Bioabsorbable Fixation System-9

Inion CPS™2.5 mm System For mandibular fixation, similar use to titanium 2.0-2.4 mm Art. No. 4 hole plate, extended 4 hole plate, extended long 6 hole plate, extended

 Open the catalog to page 9
Inion CPS™ - Bioabsorbable Fixation System-10

Inion CPS™ instruments 1.5 mm Instruments Art. No. Colour Code Length (mm) 1.2 mm drill bit short with 5 mm stop 1.2 mm drill bit with 5 mm stop 1.5 mm bone tap with 6 mm stop Colour Code 1.6 mm drill bit short with 7 mm stop 1.6 mm drill bit with 7 mm stop 2.0 mm bone tap with 7 mm stop 1.6 mm drill bit with 22 mm stop 2.0 mm bone tap with 22 mm stop 1.6 mm drill bit long with 10 mm stop 2.0 mm bone tap long with 10 mm stop Colour Code 2.10 mm drill bit short with 8 mm stop 2.10 mm drill bit with 11 mm stop 2.5 mm bone tap with 10 mm stop Colour Code Colour Code

 Open the catalog to page 10
Inion CPS™ - Bioabsorbable Fixation System-11

Universal screwdriver blade Universal screwdriver blade long Universal screwdriver handle (Manual Coupling) Plate bending pliers Transbuccal trocar set complete (containing INS-9042, Screw cutting pliers Inion Thermo™ (water bath 230v) Inion Thermo™ (water bath 110v) Inion Thermo™ drape Inion universal instrument tray Inion compact instrument tray

 Open the catalog to page 11
Inion CPS™ - Bioabsorbable Fixation System-12

Key evidence Ali AA, Kabbash MM, Said S, Shoeib MA, Osman MH. Use of biodegradable plates and screws in the treatment of pediatric facial bone fractures. Egyptian J Oral & Maxillofacial Surg. 2016 Oct 1;7(3):86-93. Losken HW, van Aalst JA, Mooney MP, Godfrey VL, Burt T, Teotia S, Dean SB, Moss JR, Rahbar R. Biodegradation of Inion fast-absorbing biodegradable plates and screws. J Craniofac Surg. 2008 May;19(3):748-56. Baek RM, Min KH, Heo CY, Eun SC. The perilobule approach to subcondylar fractures. Ann Plast Surg. 2011 Mar;66(3):253-6. Nieminen T, Rantala I, Hiidenheimo I, Keränen J, Kainulainen...

 Open the catalog to page 12

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.