Catalog excerpts

TECHNICAL SPECIFICATION 6.3 kg (base unit) 7.7 kg (with battery and paddles) Pads/Paddles, 3-, 5-, and 10-lead cables and EXT ECG cable Gain Speed High-pass, mains (50/60 Hz) and adjustable Low-pass filters Heart Rate Display Pacemaker detection 7” (177.7 mm) diagonal, active area 152.4 x 91.4 mm Color WVGA TFT LCD, LED backlight, adjustable brightness Defibrillator protection Overload Recovery Time Viewing angle 170 degrees left/right and up/down Lead-Off detection Mains Power Supply Number of displayed ECG 13 (12 leads and 1 rhythm) waves Pulse Rate For Lower and Upper limits, No Finger and sensor fall-off Non-Invasive Blood Pressure (Optional) Power Factor 0.97 with Power Factor Correction Battery Type Capacity Indicator More than 5 hours continuous monitoring or 200 shocks at 200J 5-stage indicator on screen and LED indicator when turned off Charge time Less than 2 hours for full charge Systolic: 40..260 mmHg, Diastolic: 25..200 mmHg Systolic, Diastolic, Mean, Rate, Time of Last Measurement For Lower and Upper limits and cuff fault Displayed values Alarms Capnography (Optional) Type Respiration Rate Display For Lower and Upper limits and sensor fall-off Defi electrodes STARTM Biphasic Truncated Exponential Alarm System Energy for external defibrillation 3-level intelligent alarm system Visual Alarm Multicolor, configurable Energy Selection From paddles or front panel buttons, programmable for AED Audible Alarm Different sounds, configurable Charge Time Automatic Actions Event Storage, Automatic Printout (configurable) Energy Availability Automatic disarm after 30 sec Data Storage Patient Impedance Range 15..200 ohms with indicator Demand (VVI) and Fixed Rate (VVO) Export capability Transthoracic non-invasive Report Browser Software On PC, from exported USB data Rectilinear, constant current Pulse Width Thermal Strip-Chart Recorder Current Amplitude Paper Width 360 J biphasic 2.7 sec charging time AED mode Pacer 12-channel ECG SpO2 NIBP Capnography Temperature measurement • IBP measurement Alarm conditions, manual events, shocks Stored events Internal memory Pacemaker (Optional) H-1146 Budapest, Szabó József u. 12. Phone: (+36-1) 460-9200 Fax: (+36-1) 460-9222 E-mail: innomed@innomed.hu Web: www.innomed.hu Sync Time Pulseoxymetry (Optional) Innomed Medical Biphasic Defibrillator Storage Temperature Biphasic Defibrillator Operating Temperature Online, Stored Waves, Stored Events Patient Impedance Range 0..1000 ohms with indicator Temperature measurement (Optional) Channels Peripheral, ventricular All brand names and logos are owned by their respective owners. All rights reserved. We reserve the right for modifications. Recorder (Optional) Reports Automatic Printing Events, Device Information, Date, Time, Modes, Parameters, Name Configurable for Events, Shocks, Alarms Innomed Medical Developing and Manufacturing Inc. H-1146 Budapest, Szabó József u. 12. Phone: (+36-1) 460-9200 Fax: (+36-1) 460-9222 E-mail: innomed@innomed.hu Web: www
Open the catalog to page 1
Accessories and options Multifunctional paddles state-of-the-art technologies which make quick life saving possible. Cardioversion Using the latest technologies, the delay of detec- set alarm limits, or any sensor problem occurs, the device gives fully configurable visual and audible alarms and stores the event as well. chest impedance. The actual patient impedance is displayed on the screen on a bargraph, and a Event storage and printing voice message also warns the user in case of insuf- The event storage system is capable of storing Cardio-Aid® 360-B defibrillator is available in differ-...
Open the catalog to page 2All Innomed Medical catalogs and technical brochures
-
CardioAid-1
2 Pages
-
TOP-X 100LC
2 Pages
-
TOP-X 100NR
2 Pages
-
InnoCare-T17 Plus
2 Pages
-
InnoCare-T12 Plus
2 Pages
-
Cardio PC/E
2 Pages
-
HeartScreen 210
2 Pages
-
HeartScreen 112 C-1
2 Pages
-
HeartScreen 80 GL-1
2 Pages
-
Cardio-Aid TM 360-B
2 Pages
-
HeartScreen 80G-L
2 Pages
-
TOP-X 100NR generator
2 Pages
-
InnoCare-T12
2 Pages
-
Cardio-Aid 360B_2013
2 Pages
-
ArguSys++
2 Pages
-
CardioPC/E
2 Pages
Archived catalogs
-
HeartScreen 60G VET
2 Pages
-
InnoCare VET
2 Pages
-
CardioAid 200B
3 Pages
-
PI-PACS Chest CAD
2 Pages
-
InnoCare-CC
2 Pages
-
InnoCare-S
2 Pages
-
HeartScreen 80C-L
2 Pages
-
HeartScreen 112Clinic
4 Pages
-
HeartScreen 80 CL
2 Pages
-
HeartScreen 60G
2 Pages
-
HeartScreen 60-IKO
2 Pages