1. Catalogs
  2. Innomed Medical
  3. Cardiopulmonary Exercise system
video corpo

Cardiopulmonary Exercise system

Cardiopulmonary Exercise system

Cardiopulmonary Exercise system

Product catalog summary
Overview: Cardiopulmonary exercise testing is a comprehensive method to evaluate the integrative responses of the pulmonary and cardiovascular systems during exercise. It is particularly useful for assessing unexplained exercise intolerance and exercise-related symptoms.
Exercise Protocols: The system supports various exercise protocols including bicycle and treadmill exercises. Protocols are customizable and include progressive incremental bicycle protocols, step and ramp protocols, maximal incremental treadmill protocols (Bruce and Balke), constant work rate protocols, and multistage exercise protocols with pseudo steady states.
Patient and Staff Comfort: The system features a small, lightweight patient circuit with a PinkFlow flow meter that has no moving parts or electrical connections. It offers both single-use and disinfectable patient circuits, ensuring comfort and hygiene.
Measurement Modes: The system provides breath-by-breath gas analysis, optional mixing chamber gas analysis, and measurements of Forced Vital Capacity (FVC), Inspiratory Vital Capacity (IVC), and Maximal Voluntary Ventilation (MVV). It also includes normal ECG recording and Wasserman’s 9 basic graphs, along with 17 types of VO2 graphs.
Technical Specifications: The PinkFlow flow meter operates on a symmetric and averaging Pitot tube principle with a flow range of ±18 l/s and an accuracy of ±2% or 50 ml. The CO2 gas analyzer uses NDIR technology with a range of 0-10% and an accuracy of 0.05%. The O2 gas analyzer can be a chemical cell or paramagnetic sensor with a range of 0-100% and similar accuracy. The ECG system features 12 standard leads with high-resolution data capture.
Ergometers and Accessories: The system is compatible with LODE Corival bicycles, LODE OEM treadmills, Ergosana bicycles, and Ergoline bicycles. Accessories include the PinkFlow flow meter, facial masks in various sizes, and a high-precision calibration syringe.
Measured Parameters: Key parameters measured during the ergospirometer exercise test include minute ventilation (VE), tidal volume (VT), breath frequency (fR), oxygen consumption (VO2), maximal oxygen consumption (VO2max), carbon dioxide production (VCO2), respiratory exchange ratio (RER), anaerobic threshold (AT), systolic and diastolic blood pressure (Syst and DIA), and heart rate (HR).
See more

Catalog excerpts

Cardiopulmonary Exercise system-1

CARDIOPULMONARY EXERCISE SYSTEM Cardiopulmonary exercise testing provides a global assessment of the integrative exercise responses involving the pulmonary and cardiovascular system. Ergospirometry is increasingly being used in a wide spectrum of clinical applications for the evaluation of undiagnosed exercise intolerance and exercise-related symptoms. Exercise modes • • • • Bicycle and treadmill Selectable and user definable exercise testing protocols Progressive incremental bicycle exercise protocols Step and Ramp Comfortable solutions for the patient and for medical staff as well • • • • Extremely small and light patient circuit PinkFlow flow meter without any moving parts and electrical connection Single use or disinfectable patient circuit Automatic calibration and self test Maximal incremental treadmill protocols Bruce protocol and Balke protocol Constant work rate protocol Multistage exercise protocol with a pseudo steady state at each level Discontinuous protocol Measurement modes • • • • • • • • Breath by breath gas analysis Mixing chamber gas analysis (optional) FVC (Forced Vital Capacity) measurement IVC (Inspiratory Vital Capacity) measurement MVV (Maximal Voluntary Ventilation) measurement Normal ECG recording Wasserman

 Open the catalog to page 1
Cardiopulmonary Exercise system-2

Cardiopulmonary Exercise System Ergospirometer technical data: Flow meter Pink Flow Principle Symmetric and averaging Pitot tube Flow range ± 18 l/s Accuracy ± 2 % or 50 ml whichever is higher Dead space 36 ml Resistance 60 Pa l/s @15 l/s CO2 gas analyser NDIR Range 0-10 % Accuracy 0,05 % Response time T90 130 ms O2 gas analyzer Chemical cell or paramagnetic oxygen sensor Range 0-100 % Accuracy 0,05 % Response time T90 130 ms ECG USBH-12 Leads 12 standard, simultaneous Resolution 18 bit A/D, 2.5 uV/bit applied to ± 10 mV signal range Size without patient circuit 120 x 65 x 23 mm Weight 200 g...

 Open the catalog to page 2

All Innomed Medical catalogs and technical brochures

  1. CE MDD

    2  Pages

  2. ISO 9001

    2  Pages

  3. ISO 13485

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.