IV4 Brochure en

IV4 Brochure en

IV4 Brochure en

Product catalog summary
Overview: The B.IV4 Strip-type Biosensor by Jobst Technologies is designed for various bioanalytical applications, offering enzyme-based amperometric measurement with high reliability and stability. It is suitable for industrial applications and compatible with gamma and beta sterilization.
Benefits & Characteristics:
  • Enzyme-based amperometric measurement
  • Outstanding reliability and long-term stability
  • Fast response time
  • On-chip reference, counter, and blank electrodes
  • Small size suitable for dip-in applications
Technical Data:
  • Measurement Principle: Enzymatic amperometric using oxidase enzymes and H2O2 oxidation
  • Electrodes: Platinum working electrode with enzyme membrane, silver/silver chloride reference electrode, platinum counter electrode
  • Measurable Analytes: Glucose, Lactate, Glutamine, Glutamate (on request)
  • Operating Range at 37°C: Glucose: 0.1 mM to 50 mM, Lactate: 0.05 mM to 25 mM
  • Sensitivity at 37°C: Typical 0.4 nA/mM for glucose
  • Sterilization: Compatible with beta and gamma irradiation, recommended dose < 25 kGy
  • Response Time: < 90 seconds at 37°C
  • Storage Conditions: +4°C to +35°C, desiccated
  • Operational Lifetime: Glucose: > 120 days at 20 mM, Lactate: > 7 days at 8 mM
  • Operating Temperature: 15-42°C
  • pH Range: 6-8
  • Suitable Media: Bicarbonate, acetate, imidazole buffers
Order Information:
  • Glucose Sensor: B.IV4.G.FC
  • Glucose with IDC: B.IV4.G.IDC
  • Lactate with IDC: B.IV4.L.IDC
Disclaimer: For evaluation use by professionals only. Not for medical, diagnostics, or use on humans.
See more

Catalog excerpts

IV4 Brochure en-1

Strip-type biosensor For various bioanalytical applications A product of Jobst Technologies Enzyme-based amperometric measurement Outstanding reliability Excellent long-term stability Fast response time Reference, counter and blank electrodes on-chip Gamma and beta sterilization compatible Suitable for dip-in applications Small size

 Open the catalog to page 1
IV4 Brochure en-2

Technical Data Dimensions See illustration above. Dimensions in mm Measurement principle: Enzymatic amperometric (oxydase enzymes and H2O2 oxydation) Working electrode: Platinum covered with enzyme membrane Blank electrode: Reference electrode: Silver / silver chloride Counter electrode: Measurable analytes: on request: Glucose Lactate, Glutamine, Glutamate Operating measurement range at 37 °C: - measured in acetate buffer at 37°C - contact IST AG for buffer composition - other measurement ranges on request Glucose: Notes: typical 0.4 nA/mM - measured in acetate buffer at 37°C - contact IST AG...

 Open the catalog to page 2
IV4 Brochure en-3

Product Image Left: B.IV4 Sensor with IDC Center: B.IV4 Sensor Right: Sensing area Order information Glucose Order Code Former order code Other analytes Disclaimer For evaluation use by professionals only. Not for medical, diagnostics and use on humans. For more information contact IST AG. Innovative Sensor Technology IST AG, Stegrütistrasse 14, 9642 Ebnat-Kappel, Switzerland Phone: +41 71 992 01 00 | Fax: +41 71 992 01 99 | Email: [email protected] | www.ist-ag.com All mechanical dimensions are valid at 25 °C ambient temperature, if not differently indicated • All data except the mechanical dimensions...

 Open the catalog to page 3