LV5 Brochure en

LV5 Brochure en

LV5 Brochure en

Product catalog summary
Overview: The B.LV5 Biosensor Array by Jobst Technologies is a flow-through sensor designed for bioanalytical applications. It is enzyme-based and suitable for multiparametric measurements, offering excellent long-term stability and reliability. The sensor is compatible with gamma and beta sterilization and is suitable for both industrial and research applications.
Technical Specifications:
  • Measurement Principle: Enzymatic amperometric using oxidase enzymes and H2O2 oxidation.
  • Electrodes: Platinum working electrode with enzyme membrane, silver/silver chloride reference electrode, and platinum counter electrode.
  • Measurable Analytes: Glucose, Lactate, Glutamine, Glutamate, Pyruvate (on request).
  • Operating Measurement Range: Glucose: 0.05 mM to 25 mM, Lactate: 0.02 mM to 15 mM.
  • Sensitivity: Glucose: 0.8 nA/mM, Lactate: 2 nA/mM.
  • Sterilization: Compatible with irradiation (beta, gamma), recommended dose < 25kGy.
  • Response Time: ~15 min to first measurement, < 25 s time response at 37°C.
  • Temperature Influence: Glucose: ~3.8%/°C, Lactate: ~3.2%/°C.
  • Storage Conditions: +4°C to 28°C, desiccated, with a shelf life of over 6 months from delivery.
  • Operational Life Time: Glucose: > 60 days at 20 mM, Lactate: > 7 days at 8 mM.
  • Operating Temperature: 15°C - 42°C, pH Range: 6 - 8.
  • Flow Cell: Internal volume approx. 1 µl, tubing inner diameter 0.5 mm.
  • Fluidic Connection: Inlet: male luer lock, Outlet: female luer lock.
  • Electrical Connection: Flex-print circuit, 8 pins, compatible with FFC/FPC ZIF connectors.
Usage Notes: The sensor is not sterile upon delivery and should not be used with organic solvents. It is designed for use in buffered media only, with specific buffer requirements. It is not suitable for direct use in tap water or DI-water.
Order Information: The sensor is available in different configurations, with specific order codes for each type. It is intended for research and development purposes only and is not for medical or diagnostic use.
Disclaimer: The product specifications are subject to change without notice, and the information provided is for informational purposes only.
See more

Catalog excerpts

LV5 Brochure en-1

Biosensor array A flow-through sensor for bioanalytical applications A product of Jobst Technologies Enzyme-based amperometric measurement Suitable for multiparametric measurements Excellent long-term stability Outstanding reliability Stable in continuous monitoring and analyzer mode Fast response time Reference, counter and blank electrodes on-chip Gamma and beta sterilization compatible Integrated flow cell (small inner volume) Suitable for flow-through applications For industrial and research applications Illustration B.LV5 sensor with tubes

 Open the catalog to page 1
LV5 Brochure en-2

B.LV5 sensor ruggedized (luer) length of outlet line: 100 ± 25 mm Technical Data Dimensions: Measurement principle: Enzymatic amperometric (oxydase enzymes and H2O2 oxydation) Working electrode: Platinum covered with enzyme membrane Blank electrode: Reference electrode: Silver / silver chloride Counter electrode: Measurable analytes: On request: Glucose, Lactate Glutamine, Glutamate, Pyruvate Operating measurement range at +37 °C

 Open the catalog to page 2
LV5 Brochure en-3

Sensitivity (typical): - measured in acetate buffer at 37 °C - contact IST AG for buffer composition - other measurement ranges on request - measured in acetate buffer at 37 °C - contact IST AG for buffer composition - other measurement ranges on request - info on other analytes on request Compatible sterilization method: Irradiation (beta, gamma) - recommended dose: < 25kGy - sensitivity increases with applied dose - lifetime decreases with applied dose Product is delivered not sterile Do not use organic solvents For more information contact IST AG Time (t90%) to first measurement: ~15 min at...

 Open the catalog to page 3
LV5 Brochure en-4

Electrical connection: B.LV5 Sensor (FPC) flex-print circuit, 8 pins, 1 mm pitch, 0.3 mm thickness, compatible with FFC/FPC ZIF connectors B.LV5 Sensor ruggedized (ECC) edge-card connector, 40 pins in two rows (only 8 are used), 0.635 mm pitch, 1.6 mm thickness, compatible with MEC6-RA socket General note: Performance data in this document was determined in acetate buffer at 37 °C, pH 7 and normal atmospheric conditions. Product Photos B.LV5 sensor with tubes B.LV5 sensor ruggedized (luer) B.LV5 Sensor ruggedized (luer)

 Open the catalog to page 4
LV5 Brochure en-5

Order Information Construction B.LV5 sensor with tubes (0.5 mm) B.LV5 sensor ruggedized (0.5 mm luer) Measured analytes Glucose, Lactate Glucose, Lactate other analytes Measurement range other ranges Order code Former order code Disclaimer Evaluation product for professionals to be used solely for research and development purposes! Not for medical and diagnostic use. Not to be used on humans. For more information contact IST AG. Innovative Sensor Technology IST AG, Stegrütistrasse 14, 9642 Ebnat-Kappel, Switzerland Phone: +41 71 992 01 00 | Fax: +41 71 992 01 99 | Email: [email protected] | www.ist-ag.com...

 Open the catalog to page 5