C3 Cryo System

C3 Cryo System

C3 Cryo System

Product catalog summary
Application Area
The document discusses the use of the C3 CryoSystem for treating chronic pain in the lumbar, thoracic, and cervical facet joints, as well as sacroiliac joint pain. It highlights the system's application in intraoperative neuromonitoring, functional neurosurgery, pain treatment, and neurological diagnostics.
Indications and Benefits
Cryoanalgesia is primarily indicated for treatment-resistant chronic pain, particularly lumbar facet syndrome. It serves as an alternative when traditional pain therapies fail, offering lasting pain relief by selectively interrupting pain signal conduction. The C3 CryoProbe allows for cryotherapy on peripheral nerves, ensuring no risk to sensory and motor nerves, and supports minimally invasive, ambulatory treatments.
System Features
The C3 CryoSystem features an intuitive graphical user interface, facilitating easy navigation through treatment processes. It includes a foot switch for managing procedures and documentation. The system's integrated electrical stimulator aids in precise target localization, and an automated rinsing procedure ensures safe probe extraction.
Procedure
The procedure involves identifying the target area using imaging techniques, inserting the C3 CryoProbe, and applying cryotherapy. It is applicable to various conditions, including spinal facet syndrome, postnucleotomy syndrome, coccygodynia, post-thoracotomy pain, intercostal neuralgia, neuroma pain syndromes, and scar pain.
Product Specifications
The document lists various disposable and reusable components, including cryo-disposable cannulas and C3 CryoProbes, with details on dimensions, sterilization, and reusability. The foot switch for the C3 CryoSystem is also mentioned.
Contact Information
For further information, contact inomed Medizintechnik GmbH at their Emmendingen, Germany location, or visit their website.
See more

Catalog excerpts

C3 Cryo System-1

Intraoperative Neuromonitoring Functional Neurosurgery Pain Treatment Neurological Diagnostics C3 CryoSystem >> Application are a Lumbar, thoracic and cervical facet joint denervation and treatment of sacroiliac joint pain Freezing to end back pain! Freezing to eliminate back pain!

 Open the catalog to page 1
C3 Cryo System-2

> Cryoanalgesia The Application The main indication for cryoanalgesia is treatmentresistant chronic pain in the spinal area – most commonly the lumbar facet syndrome. If medical pain therapy or facet joint injections do not alleviate chronic back pain, following a definitive diagnosis, neurodestructive treatments can bring lasting abatement. By selective interruption or modification of the pain signal conduction, cryoanalgesia is an effective alternative for pain relief. The special C3 CryoProbe from inomed allows cryotherapy to be applied to the peripheral nerve. Intuitive Handling The C3 CryoSystem...

 Open the catalog to page 2
C3 Cryo System-3

> PROCEDURE Identification of the target area using imaging techniques Automated rinsing procedure > lasting pain relief through selective 2. Insertion of the C3 CryoProbe, optionally after positioning of the cannula interruption of the pain signal conduction > no risk for the sensory and motor nerves > minimally invasive Integrated electrical stimulator enables precise localization of the target point dorsal skin > ambulant treatment possible > additional therapeutic treatments such as physiotherapy support the lasting spinous process effects of pain relief pain nerve fibers > replication possible...

 Open the catalog to page 3
C3 Cryo System-4

Intraoperative Neuromonitoring Functional Neurosurgery Pain Treatment Neurological Diagnostics inomed £3we share competence >> Partnership >> Precision >> innovation inomed Medizintechnik GmbH Im Hausgruen 29 79312 Emmendingen (GERMANY) Tel. +49 7641 9414-0 Fax +49 7641 9414-94 [email protected] www.inomed.com Article information Cannulas Art.-No. 217 660 Cryo-Disposable cannula for C3 CryoProbe 2.1 mm with mandrin, total length 96.3 mm, working length 62.5 mm, OD = 2.6 mm • disposable product • ETo-sterilized Foot switch Art.-No. 217 680 Cryo- Disposable cannula for C3 CryoProbe 2.1 mm with mandrin,...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.