Stereotactic Systems - 1

Intraoperative Neuromonitoring Functional Neurosurgery Pain Treatment Neurological Diagnostics >> Applications Stereotactic Target Point Planning Biopsy Planning Deep Brain Stimulation Stereotactic Systems

Open the catalog to page 1
Stereotactic Systems - 2

Superior Medical technology: inomed Functional Neurosurgery products. High quality precision products from inomed ensure that tissue trauma is significantly reduced during sensitive surgical procedures. Using inomed products hospitals and clinics are able to deliver the gold standard treatment in the field of Functional Neurosurgery. inomed offers a complete system approach, including a wide range of fixation options that enables a precision connectivity solution to be realised. A successful stereotactic procedure requires a solid foundation. The inomed stereotactic ring provides the...

Open the catalog to page 2
Stereotactic Systems - 3

>> Quick and safe assembly An assortment of different lengths of OptiPins guarantees a suitable fixation for all cranium sizes. The post pones used for the fixation of the titanium ring offer a flexible position for the OptiPins. The post pones used for the fixation at the ceramic ring are made entirely of carbon fiber and are therefore completely artifact free for MRI and CT scans. The inomed ceramic ring guarantees zero The titanium stereotactic ring offers an ideal interference and zero artifacts for the MRI. balance between stability and lightweight The half-open ceramic ring minimises...

Open the catalog to page 3
Stereotactic Systems - 4

Z Methodical planning of a procedure is essential for a safe and effective surgical outcome. The use of the inomed iPS planning software is the very first step in the preparation of the surgical intervention. Neurosurgeons devote substantial time to plan a procedure to help ensure a successful patient outcome. > IPS Planning software and localization set To ensure precise calculation of the target coordinates reliable localization systems are necessary. Due to the design of the inomed localization set, bracing of the plates is avoided and a credible and constant quality of the image data...

Open the catalog to page 4
Stereotactic Systems - 5

X- value Y- value Z- value inomed iPS planning software is designed for all stereotactic treatments and compatible with most frames. The 3D software is characterised by precision-combination, high quality imaging and fusion. Optional anatomical atlases can be projected over patient-related data. This enables verification on the basis of anatomical information. After finalising planning the calculated coordinates are transmitted to the stereotactic system and a precise and safe surgery is possible. >> Fusion applied to CT and MRI images CT-image with localisers The core function of iPS is...

Open the catalog to page 5
Stereotactic Systems - 6

Functional Neurosurgery does not tolerate errors. The use of simulation techniques mean that slightest inaccuracy of the settings or damage to the instruments are no longer incalculable risks but preventable incidents. > Target point simulator

Open the catalog to page 6
Stereotactic Systems - 7

< Precision into the µ-area The simulation of the stereotactic procedure with the inomed target point simulator enables a clinician to verify the method and instruments with an accurate representation of the target point. Surgical planning with the iPS planning software provides coordinates that can accurately and easily be transferred onto the target point simulator. The ability to rehearse the procedure with the target point simulator provides verification and the highest levels of patient safety.

Open the catalog to page 7
Stereotactic Systems - 8

X- value Y- value Z- value > RM System >> High stability and precision The RM-System offers a 3-point-fixation based on the polar coordinate system. Professor Traugott Riechert and Professor Fritz Mundinger (Freiburg) developed a precision mechanical system with an aiming bow that can be used simultaneously as a probe holder. A large variety of accessories create numerous possibilities and permit universal application in the field of stereotaxy. The inomed RM-System is one of the most precise target point systems and was developed especially for stereotactic surgeries in the field of...

Open the catalog to page 8
Stereotactic Systems - 9

The stereotactic system named after Zamorano-Duchovny (ZD-System) is an easy-to-handle, stable and precision engineered product. This type of a single point-fixation device is proven worldwide in numerous neurosurgical centers. Based on the Center-of-arc principle the method ensures nearly unlimited access to all intracranial regions - and free choice of the trepanation point. Depending on the surgeon’s needs and preference, inomed’s RM- and ZD-systems are the preferred choices for biopsy and deep brain stimulation. inomed also offers a Microdrive and accessories for use with RM and ZD...

Open the catalog to page 9
Stereotactic Systems - 10

Functional Neurosurgery requires more than sensitivity – it requires a highly developed haptic perception. Instruments and equipment intended as extensions to the surgeon’s hands requires reliable technology with precise functionality. Stimulation A systematic approach to deep brain stimulation procedures is essential. The MicroDrive with its depth stops guarantees that electrodes and guide tubes cannot be incorrectly mounted. After each complete turn of the MicroDrive handle, the surgeon/ neurologist receives haptic feedback (“click”). The inomed ISIS MER system is a high quality and easy...

Open the catalog to page 10
Stereotactic Systems - 11

>> MicroDrive The MicroDrive is used for the positioning of recording and stimulation electrodes during stereotactic surgeries. It is possible to load up to five electrodes simultaneously during the operation. The recording can start with a single electrode. A precise positioning of the electrode is possible due to the 50 µm resolution and haptic feedback at each turn. The MicroDrive and its accessories are autoclavable, and can be adapted to most stereotactic systems.The MicroDrive can be used independently of the MER recording system. The assortment of biopsy instruments for tissue...

Open the catalog to page 11
Stereotactic Systems - 12

Intraoperative Neuromonitoring Functional Neurosurgery Pain Treatment Neurological Diagnostics inomed Medizintechnik GmbH Im Hausgruen 29 79312 Emmendingen (GERMANY) Tel. +49 7641 9414-0 Fax +49 7641 9414-94 info@inomed.com www.inomed.com Further information is available on our website: www.inomed.com D030201 EN / Content subject to alterations ©copyright by inomed 07.2016 REV1.0

Open the catalog to page 12