Camera Specifications
The double head operating light features a Full HD Analog Camera with a 1/3” type CMOS sensor, providing Full HD 1920x1080p resolution and 10x optical zoom. It includes HDMI video output and AutoFocus capabilities.

Standards
The device is classified as Class 1 under MDD 93/42 EEC and conforms to EU standards CE, EN 60601-1, and EN 60601-2-41.

Package Dimensions
The package measures 100x120x115 cm and weighs 145 kg.

Material Specifications
The lamp head and joint handle are made of static painted aluminum and polycarbonate, while the sterile handle is made of ABS + PC plastic. The handle should be sterilized at 134°C for 3.5-5 minutes or at 121°C for 10 minutes.

Technical Specifications
Main Lighthead: Diameter Ø670 mm, Illumination power 160,000 Lux, Adjustable color temperature 3000 K - 5000 K, CRI 96%, Dimming range 1-100%, Light field diameter d10 24-36 cm, d50 13-28 cm, 60 LED modules, Lifetime >60,000 h, IP 43, Power consumption 130 W, Degree of turbulence 29%, Irradiance 510 W/m², UV radiation intensity 0.2 W/m², Depth of light 130 cm at 20%, 76 cm at 60%, Weight 13.2 kg.
Satellite Lighthead: Diameter Ø490 mm, Illumination power 120,000 Lux, Adjustable color temperature 3000 K - 5000 K, CRI 96%, Dimming range 1-100%, Light field diameter d10 25-27 cm, d50 12-14 cm, 28 LED modules, Lifetime >60,000 h, IP 43, Power consumption 55 W, Degree of turbulence 25%, Irradiance 430 W/m², UV radiation intensity 0.2 W/m², Depth of light 185 cm at 20%, 92 cm at 60%, Weight 9 kg.

Other Specifications
The light includes a laser positioning guide for easy alignment, an Auto Light feature for consistent intensity, and a StandBy/Endo Light Mode with blue LED strips. A 4.3” LCD touch screen control unit allows easy operation. The Active Illumination Control (AIC) system compensates for any blocked LEDs to maintain optimal illumination.

Technical Drawing
The document includes a technical drawing with dimensions and tolerances for installation and setup.
See more

Catalog excerpts

Double Head Operating Light with Camera Model : LD20.52S-1

DATA SHEET Double Head Operating Light with Camera Model : LD20.52S Inspital LED operating lights are designed to meet all lighting and viewing requirements of operating theatres. Powerful LED technology with high-tech camera option helps the surgeons to operate and view the surgery area clearly. LED lights can be adaptedin any size of operating theatres including large hybrid types with variety of models & combinations. The light is designed with advanced shadowless technology to minimize obstruction and ensure optimal visibility during procedures. MATERIAL SPECIFICATIONS Lamp Head Static Painted (RAL 9002) Aluminum / Polycarbonate Joint Handle Static Painted (RAL 9002) Aluminum Sterile Handle Plastic (ABS + PC) PACKAGE DIMENSIONS The handle should be sterilized at 134 °C between 3.5-5 minutes and at 121°C during 10 minutes. CAMERA SPECIFICATIONS Full HD Analog Camera 1/3” type CMOS sensor Full HD 1920x1080p 10x optical zoom HDMI video output AutoFocus INSPITAL MEDICAL TECHNOLOGY GmbH

 Open the catalog to page 1
Double Head Operating Light with Camera Model : LD20.52S-2

DATA SHEETDouble Head Operating Light with Camera Model : LD20.52S TECHNICAL SPECIFICATIONS MAIN LIGHTHEAD SATELLITE LIGHTHEAD Diameter of lighthead with outer handle Illumination power, at 1 m Color temperature (adjustable) Color rendering index, Ra CRI Dimming Range (adjustable) Light Field Diameter d10 Light Field Diameter d50 Number of LED modules Lifetime of LED IP Total power consumption (max) Degree of turbulence(standard value 37.5% max.) Irradiance at nominal illuminance Depth of the volume of light L1 + L2 at 20% Input Voltage Weight of lighthead Additional options Number of lighthead...

 Open the catalog to page 2
Double Head Operating Light with Camera Model : LD20.52S-3

DATA SHEET Double Head Operating Light with Camera Model : LD20.52S Note: ± 25 mm tolerance is given for metric measurements and ± 5° tolerance is given for angle measurements. INSPITAL MEDICAL TECHNOLOGY GmbH

 Open the catalog to page 3
Double Head Operating Light with Camera Model : LD20.52S-4

DATA SHEET Double Head Operating Light with Camera Model : LD20.52S OTHER SPECIFICATIONS * Active Illumination Control (AIC) Inspital LED light technology provides the best illumination, even when surgeons are blocking the LEDs. The loss of illumination when certain LEDs are obstructed is automatically compensated by the AIC system. * StandBy Mode/ Endo Light Mode Stylish blue LED strips in standby mode. Endo light mode can be activated with one touch, switching immediately and ready for endoscopic procedures. * Laser Positioning Guide Each light head has a laser guide to easily and efficiently...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.