TECHNICAL INFORMATION GENERAL SPECIFICATIONS • Dimensions with pads: -- 30,0 cm (11.81 in) length. -- 21,5 cm (8.46 in) depth. -- 28,0 cm (11.02 in) height. • Weight: -- Device - 4.90 Kg (10.80 lbs). -- Battery - 0.75 Kg (1.65 lbs). -- Ext. pads - 0.85 Kg (1.87 lbs). -- Complete Equipment - 6.50 Kg (14.33 lbs) (except for NIBP). • Electrical: -- AC: 100 to 265 VAC, 50/60 Hz (automatic selection). -- DC external: 11 to 16 VDC. • Replaceable battery: -- Type: NiMH, 14.4 VDC 4.5 A/h. -- Duration: Battery with full charge 3 hours in monitor mode, without printer, or a minimum of 140 shocks at 360 joules or a minimum of 200 shocks at 200 joules. -- Battery full-charge time (when fully unloaded): 8 hours. -- OPTIONAL: -- Type: Li-Ion, 14.8 VDC 4.4 A/h. -- Duration: Battery with full charge - 3 hours in monitor mode, without printer, or a minimum of 140 shocks at 360 Joules or a minimum of 200 shocks at 200 joules. -- Battery full-charge time (when fully unloaded): 8 hours. • Memory: -- Type: Nand Flash. -- Capacity: 2 Mbytes. -- Patients stored >150 patients. -- Storage: 15 seconds of ECG -- when in shock, physiological alarm and panel events. -- ECG: 2.5 continuous hours of ECG curve recording. ENVIRONMENTAL SPECIFICATIONS • Temperature: -- Operational: 0 to 50ºC. -- Storage: 0 to 70ºC. • Humidity: -- Operational: 10 to 95% RH, without condensation. -- Storage: 10 to 100% RH, without condensation. -- Controls: On/Off button, charge, shock, synchronism. -- Power selection: Therapy button on the front panel. -- Charge control: Button on the front panel, button on the external pads. -- Shock control: Button on the front panel, buttons on the external pads. -- Synchronized control: SYNC button on the front panel. • Charge indicators: -- Sound signal of equipment being charged. -- Sound signal of completed charge. -- LED on external pads and charge level indicated on the display. • Maximum charging time: -- (200J): network and battery < 4s. -- (360J): network and battery < 6s. • Electrode size: -- Adult: 10.3 cm (4.05 in) x 8.5 cm (3.34 in). Contact area: 81.9 cm2 (12.69 inches2) -- Children: 4.5 cm (1.77 in) x 4.0 cm (1.57 in). Contact area: 18 cm2 (2.79 inches2) • Pads (options): -- Adult and child external (included). -- Adult and child internal (optional). -- Multifunctional for pacemaker, monitoring and defibrillation (optional). -- Multifunctional extension (optional). AED MODULE (OPTIONAL) • Functional characteristics: -- Voice instructions, visual indications, CPR instructions, USB 2.0. Multilanguage, Sudden Death Prevention Technology (SDP). • USB: -- USB 2.0 for transfer of the electrocardiogram stored in AED mode to a compatible PC. • SoftDEA: -- Software for viewing the data transferred to the PC. EXTERNAL PACEMAKER (OPTIONAL) • Modes: DEFIBRILLATOR • Waveform: -- Biphasic truncated exponential. Waveform parameters adjusted in terms of patient’s impedance. • Shock application: -- By means of multifunctional pads (adhesive) or defibrillation pads. -- Demand or fixed -- From 5 mA to 200 mA (resolution of 5 mA), accuracy 10%. • Frequency: -- From 30 ppm to 180 ppm (increments of 5 ppm), accuracy ± 2%. • Refractory period: -- 340 ms (from 30 to 80 ppm). -- 240 ms (from 90 to 180 ppm). NIBP (OPTIONAL) • Operating principle: -- Oscillometric. • Measurement interval: • Adult: -- Systolic: 40 - 260 mmHg. -- MAP: 26 - 220 mmHg. -- Diastolic: 20 - 200 mmHg. • Pediatric: -- Systolic: 40 - 160 mmHg. -- MAP: 26 - 133 mmHg. -- Diastolic: 20 - 120 mmHg. • Neonate: -- Systolic: 40 - 130 mmHg. -- MAP: 26 - 110 mmHg. -- Diastolic: 20 - 100 mmHg. • Overpressure limit by software: -- Adult: 290 mmHg max. -- Neonate: 145 mmHg max. • Overpressure protection by hardware: -- Adult: 300 ± mmHg. -- Neonate: 150 ± mmHg. DISPLAY • Battery level indicator: -- Yes. ECG (up to 12 derivations) • Inputs: -- 3, 5 or 10 lead ECG cable. -- External pads. -- Multifunctional pads. • Rejection in common mode: -- Greater than 90 dB, measured according to AAMI standards for heart monitors (EC 13). • ECG response frequency: -- Diagnostic mode - (0.05 -100 Hz). -- Monitor Mode - (1-40 Hz). • Patient insulation: -- Defibrillation proof. -- ECG: CF Type. -- SpO2: CF Type. • Loose Electrode: -- Identified and shown with low level alarm. • Time to restore ECG baseline after defibrillation: -- ≤ 3 seconds. CAPNOGRAPHY (OPTIONAL) • Measurement range CO2: -- 0 – 99 mmHg. • Precision: -- +/- 3% from 0 to 40 mmHg. -- +/- 8% from 41 to 76 mmHg. -- +/- 10% from 77 to 99 mmHg. PRINTER (OPTIONAL) -- Prints up to three simultaneous derivations. • Type: -- Thermal. • Speed: -- 12.5; 25 or 50 mm/s with precision of ±5%. • Paper size: -- 50 mm (width) x 30 m (maximum length). STANDARDS: -- EN 60601-1:1990 (A1:1993, A2:1995, A13:1996) -- NBR IEC 60601-1:1994 + amendment 1997 -- EN 60601-1-2:2007 -- NBR IEC 60601-1-2:2006 -- EN 60601-2-4:2003 -- NBR IEC 60601-2-4:2005 -- EN 60601-2-25:1995 (A1:1999) -- EN 60601-2-27:2006 -- NBR IEC 60601-2-27:1997 -- EN 60601-2-49:2001 -- NBR IEC 60601-2-49:2003 Folder CardioMax Eng R1-0 2013 Rua Beco José Paris, 339 - Pavilhão 19 CEP 91140-310 Porto Alegre RS Brasil Telephone: + 55 (51) 3073 8200
Open the catalog to page 1Sudden Death Prevention Now with the AED module option with SDP (Sudden Death Prevention) technology and Capnography monitoring and the new Auto Sequencing Charge function. Cardioversor Monitor Biphasic Defibrillator MORE COMPLETE IN PARAMETERS AND SOLUTIONS THAT ASSIST THE WORK OF MEDICAL PROFESSIONALS. PRACTICAL: Light. Strong, comfortable strap. Ready to use in less than 6 seconds. Designed without sharp edges, ideal for emergency transport Biphase power delivery of up to 360 Joules. The battery, which is easy to replace, allows more than 100 shocks. EASY TO USE: All operations are concentrated...
Open the catalog to page 24 Pages
4 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages