ISIS - 2013-1

TECHNICAL INFORMATION GENERAL SPECIFICATIONS • imensions: D -- 22.0 cm/8.66 in (w). -- 13.0 cm/5.11 in (d). -- 29.0 cm/11.41 in (H). • nternal Battery: I - - Type: Li-ion, 14.4 Vdc 4.0 A/h. - - Duration: 10 hours in cardiac rhythm recognition mode (full load battery) or at least 200 shocks in 200 Joules (battery under good conditions). - - Battery full load time (fully unloaded): 5 hours. • attery loader source: B -- Power supply 100 – 240V/50-60Hz. -- Consumption (max.): Power supply 1 A. -- Output: 24 Vdc, 1.5 A. • attery storage: B - - Battery storage for long periods under temperatures above 35ºC will reduce the battery’s capacity and abbreviate its useful life. • reset defibrillation scales: P -- Adult: 1st shock 150 J, subsequent shocks 200 J. -- Child: 50 J. • nternal memory storage: I -- 100 events or 2 hours of ECG record. • lassification: C -- Internal Energized Equipment. -- CF type. • ode of operation: M -- Continuous Operation. • aximum time since beginning M of rhythm analysis until promptness for discharge: -- 20 s • aximum time since beginning M of the operation until promptness for discharge at the maximum energy: -- 25 s ENVIRONMENTAL SPECIFICATIONS • emperature: T -- Operational: 0 to 50ºC/32 to 122 F . -- Storage: 0 to 70ºC/32 to 158 F . • umidity: H -- Operational: 10 to 95% RH, without condensation. -- Storage: 10 to 70% RH, without condensation. DEFIBRILLATOR • ave form: W -- Biphasic truncated exponential. wave form parameters set according to the patient’s impedance. • hock application: S -- By multifunctional adhesive pads. • ommands: C -- Front Panel button (on/off). • efibrillation scales: D -- Adult: 150 and 200 J. -- Child: 50 J. • dult/Child Selection: A -- Automatic by the type of pads. • harge command: C -- Automatic after identifying arrhythmias that should receive shock. • hock command: S -- Front Panel button, when blinking. • ads size: P -- Adult = area: 82 cm2 / 12.71 in2. -- Child = area: 30 cm2 / 4.65 in2. • aximum output voltage: M -- 1500 V • aximum output current: M -- 60 A (25 ohms) STANDARDS -- NBR IEC 60601-1:1997 (IEC606011:1995), Medical Electrical Equipment – Part 1 – General Requirements for Safety. -- EN 60601-1:1990, (Amendment, A1:1993, A2:1995, A13:1996) (IEC 60601-1:1988, A1:1991, A2:1995), Medical electrical equipment - Part 1 General Requirements for Safety. -- NBR IEC 60601-1-2:2006 (IEC60601-1-2:2004), Medical Electrical Equipment – Part 1-2 – General Requirements for Safety: Collateral Standard: Electromagnetic Compatibility – Requirements and Tests. -- EN 60601-1-2:2007 (IEC 60601-12:2007), Medical electrical equipment. General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests. -- ABNT NBR IEC 60601-1-4:2004 (IEC 60601-1-4:2000) Medical Electric Equipment - Part 1-4: General Requirements for Safety: Collateral Standard: Programmable electrical medical systems. -- IEC 60601-1-4:2000 - Medical electrical equipment - Part 1-4: General requirements for safety - Collateral standard: Programmable electrical medical systems. -- NBR IEC 60601-2-4:2005 (IEC606012-4:2002), Medical Electrical Equipment - Part 2 - Particular requirements for the safety of Cardiac Defibrillators. -- EN 60601-2-4:2003 (IEC 60601-24:2002), Medical electrical equipment. Particular requirements for safety. Particular requirements for the safety of cardiac defibrillators. -- ANSI/AAMI DF80:2003: Particular requirements for the safety of cardiac defibrillators (including automated external defibrillators). -- NBR IEC/CISP . Folder Isis Port R1-0 2013 Rua Beco José Paris, 339 - Pavilhão 19 CEP 91140-310 Porto Alegre RS Brasil Phone: + 55 (51) 3073 8200

 Open the catalog to page 1
ISIS - 2013-2

Acts in case of cardiac arrest (ventricular fibrillation and ventricular tachycardia), by voice direction, diagnosis and by automatic and safe application of shock treatment upon activation of a single button. 3 The device evaluates the patient’s condition Place the pads on the patient Directs by voice, performs diagnosis and applies treatment with just one button! Press the button to start the cycle Evaluation completed: shock recommended! THE EASY TO USE, PORTABLE, RELIABLE AND INTELLIGENT DEFIBRILLATOR. The Automated External Defibrillator (AED) ISIS, using its Neural Network Technology is...

 Open the catalog to page 2

All Instramed Indústria Médico Hospitalar catalogs and technical brochures

  1. DUALMAX

    4  Pages

  2. I.on/I.on PRO

    4  Pages

  3. Helios

    3  Pages

  4. eazy-pro

    3  Pages

  5. isis-pro

    3  Pages

  6. eazy

    3  Pages

  7. isis - 2017

    3  Pages

  8. cardiomax

    3  Pages

  9. InMax

    2  Pages

Archived catalogs

  1. CardioMax - M

    2  Pages

  2. Isis

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.