Integra® Camino® Flex Ventricular Catheter Limit Uncertainty with Continuous CSF Drainage and ICP Monitoring in One System A Tunneled Ventricular Solution to Continuous Drainage and ICP Monitoring
Open the catalog to page 1Camino® Flex Ventricular Catheter A Tunneled Ventricular Solution to Continuous Drainage and ICP Monitoring Separate Lumen Design Allows for Simultaneous CSF Drainage and ICP Monitoring • The drainage lumen supports a flow rate of approximately 300 ml/hr5 - Normal CSF production rate: approximately 25 ml/hr 6 • Multiple drainage holes help mitigate the risk of obstructions ICP Sensor with Drainage Holes Silicone Membrane Drainage Lumen Stylet Lumen Braided Tensile Member ICP Sensor Control Wires Sensor Located at the Tip of the Catheter Allows Continuous ICP Measurement in the Ventricle Regardless...
Open the catalog to page 2Integra® Camino®Flex Ventricular Catheter Flex Ventricular Catheter Elevated ICP and Missed Events Can Be Detected With Continuous Monitoring • Continuous ICP waveforms can provide qualitative information regarding brain compliance.1 • In a retrospective study of 32 traumatic brain injury (TBI) patients, the authors concluded that manually recorded end-hour ICP measurements result in the omission of a significant number of important episodes of high ICP, some for a long duration. Manual recording methods, therefore, provide a clinical picture that may not be accurate or informative of the true...
Open the catalog to page 3Continuous Monitoring... Always Informed Sensor Located at the Tip of the Catheter Allows Continuous ICP Measurement in the Ventricle Regardless of Fluid Flow • Provides uninterrupted ICP monitoring at the source, even when CSF drainage cannot be established due to slit or shifted ventricles, or becomes occluded due to bloody CSF • Continuous ICP monitoring helps avoid missed events of elevated ICP Camino Flex Ventricular Catheter can continuously monitor the ICP, even when CSF drainage lumen becomes occluded ICP of 25 mmHg Ventricular Cavity Flex Ventricular Catheter Camino Flex Ventricular...
Open the catalog to page 4Sensor at the Tip Allows Flex Ventricular Catheter to Monitor ICP Independent of Patient Position • The Camino Flex Ventricular Catheter sensor monitors ICP directly at the source, providing an accurate reading regardless of patient position • External transducers will produce inaccurate ICP readings if not properly aligned to the patient’s anatomical landmark such as the Foramen of Monro • When not properly leveled, the ICP reading will be off by approximately 0.736 mmHg, for each centimeter of vertical distance between the patient’s anatomical landmark of leveling and an external transducer7...
Open the catalog to page 5Integra® Camino® Flex Ventricular Catheter The Complete ICU Solution Supported by both the Camino ICP Monitor (CAM02) and the Camino Advanced Monitor fitted with the Camino Flex Adapter, (CAM01, FLEXADR) the Camino Flex Ventricular Catheter provides neurosurgeons access to Integra’s most advanced monitoring and CSF drainage systems for heightened confidence during challenging procedures. The new Camino Flex Ventricular Catheter, coupled with the Integra External Ventricular Drainage System, offers a unified solution to help clinicians achieve the best outcomes for their patients. Camino Flex...
Open the catalog to page 612 Pages
4 Pages
8 Pages
2 Pages
12 Pages
8 Pages
2 Pages
8 Pages
6 Pages
28 Pages
4 Pages
1 Page
4 Pages
2 Pages
6 Pages
8 Pages
16 Pages
4 Pages
2 Pages
4 Pages
3 Pages
4 Pages
2 Pages
4 Pages
107 Pages
110 Pages
36 Pages
6 Pages
2 Pages
8 Pages
26 Pages
11 Pages
10 Pages
28 Pages
4 Pages
663 Pages
28 Pages
285 Pages
322 Pages
130 Pages
916 Pages
90 Pages
87 Pages
242 Pages
28 Pages
8 Pages
177 Pages
12 Pages
76 Pages
9 Pages