Overview: This document is a technical catalog from Integra LifeSciences Corporation, detailing various medical devices and products used in neurosurgery and related fields. It includes product specifications, ordering information, and warranty details.
Advanced Biomaterials: The section covers products like DuraGen and NeuraGen, which are used for dural repair and nerve conduit/wrap applications. DuraGen Plus and DuraGen XS are highlighted for their superior handling and safety profile, being absorbable implants made from Ultra Pure Collagen™.
Cranial Stabilization and Brain Retraction: This section includes products like BUDDE and MAYFIELD, focusing on skull clamps, headrest systems, and brain retractor systems. It details various components such as base units, adaptors, and accessories.
Cranial Closure: The KraniOS system is discussed, including plates, screws, and hardware necessary for cranial closure procedures.
Ultrasonic Aspiration: Products like CUSA SELECTOR and CUSA EXcel are covered, detailing consoles, handpieces, and replacement parts used for ultrasonic aspiration in surgical procedures.
CSF Management: This section includes CSF valves, shunt kits, and various catheters used for cerebrospinal fluid management. It also covers anti-siphon devices and shunt implantation instruments.
Brain Mapping: The document details electrodes used in brain mapping, including strip, grid, depth, and epidural peg electrodes, along with electrode connecting cables and cortical stimulators.
Stereotaxy Product Catalog: This section includes head rings, imaging localizers, and stereotactic planning software, along with drills and kits for stereotactic procedures.
Ordering and Warranty Information: The document outlines pricing, minimum order requirements, shipment details, and return policies. It also includes warranty information for products, ensuring they are free from manufacturing defects under normal use.
Warranty and Liability: The document outlines the warranty terms for Integra products, emphasizing that any defects during the warranty period should be communicated directly to Integra's home office. Products must be returned properly packaged and postage prepaid. Integra's responsibility is limited to repair or replacement at their discretion. The warranty excludes liability for incidental, indirect, consequential, or punitive damages and does not cover products altered or repaired by unauthorized personnel.
Product Specifications: The document details various Integra products, including DuraGen Plus® and DuraGen XS™ Dural Regeneration Matrices, NeuraGen® Nerve Guide, and NeuraWrap™ Nerve Protector. Each product is described with its intended use, material composition, and safety profile. Catalog numbers and sizes are provided for ordering purposes.
Ordering and Pricing: Prices are subject to change and are firm for 60 days from the date of quotation. Minimum order requirements and shipping terms are specified. Orders are accepted upon approval by Integra LifeSciences Corporation, with net 30-day payment terms.
Return Policy: Returns require authorization and must be in unopened, undamaged condition. A restocking charge applies, and custom or special order products are not eligible for return.
Contact Information: Customer service contact details for Integra LifeSciences Corporation are provided for further inquiries and support.
Overview: The document provides detailed specifications and features of various MAYFIELD® products used for cranial fixation and support during surgical procedures. These include skull clamps, headrests, adaptors, and skull pins, each designed to enhance surgical precision and patient safety.
Skull Clamps and Headrest Systems:
  • MAYFIELD® 2000 Skull Clamp: Offers 3-point rigid cranial fixation with a streamlined design for better operative site exposure.
  • MAYFIELD® Infinity Skull Clamp: Features extended length and curved contours with multiple rocker arm options and torque screw options.
  • MAYFIELD® General Purpose Headrest: Provides cranial support without rigid fixation, with pads that contour to the patient's head.
  • MAYFIELD® Adult and Pediatric Horseshoe Headrests: Offer cranial support with adjustable pads and fluid-resistant gel pads for comfort.
Base Units and Adaptors:
  • MAYFIELD® NeuroGen Adaptor: Allows attachment of base units to OR tables without receptacle holes.
  • MAYFIELD® Ultra 360™ Patient Positioning System: Facilitates attachment of skull clamps and headrest systems with independent rotating handles for flexibility.
  • MAYFIELD® Ball Socket Swivel Adaptor: Provides 360-degree rotation for optimal positioning.
Skull Pins:
  • MAYFIELD® Adult and Child Disposable Skull Pins: Fit all skull clamps for rigid fixation, with designs to improve fit and grip.
  • MAYFIELD® Radiolucent Skull Pins: Made from synthetic Sapphire to reduce imaging artifacts.
  • MAYFIELD® Titanium Skull Pins: Designed for MR systems up to 3.0 Tesla, available in disposable and reusable options.
Key Features and Benefits:
  • Products are designed for enhanced surgical precision and patient safety.
  • Adaptors and base units provide flexibility and ease of use in various surgical settings.
  • Skull pins are engineered to minimize imaging artifacts and ensure secure cranial fixation.
Product Overview:
The MAYFIELD Infinity XR2 Radiolucent Base Unit is designed for enhanced stability and rigidity, facilitating the attachment of MAYFIELD Radiolucent Skull Clamps and Headrests to operating room tables. It is compatible with X-ray imaging, CT, Fluoroscopy, and Digital Subtraction Angiography (DSA). The unit is constructed from composite materials to ensure strength and durability while preserving imaging quality. Setup is simplified with color-coded dual-action knobs.

Key Features:
  • Wide imaging window for lateral positioning.
  • Compatible with various MAYFIELD accessories.
  • Improved strength and reduced imaging artifacts.

Accessories:
The document lists several accessories compatible with the MAYFIELD system, including:
  • Radiolucent Skull Clamps for 3-point fixation.
  • Horseshoe Headrests for cranial support in various positions.
  • Optional accessories like the XR2 Tri-Star Swivel Adaptor and Child's Rocker Arm.

Brain Retractor Systems:
Several retractor systems are described, including the SAMY Vascular Retractors and BUDDE Halo Retractor System, which provide platforms for retraction and support during surgery. These systems are designed to minimize artifacts during imaging and offer flexibility in positioning.

Warranty and Pricing:
Integra provides a two-year warranty against manufacturing defects under normal use. The warranty excludes damages from unauthorized repairs or misuse. Pricing is firm for thirty days from the quotation date, with a minimum order requirement of $100.

Contact Information:
For further inquiries or support, contact Integra LifeSciences through their provided phone numbers and website.
Ordering and Shipping Information:
Orders for Integra NeuroSciences products require a written purchase order. Shipments are F.O.B. from Integra's point of shipment within the continental United States, with shipping costs prepaid by Integra and invoiced to customers. Orders are accepted upon approval by Integra in Plainsboro, New Jersey.
Return Policy:
Authorization from customer service is required before returning products. Sterile products must be returned in unopened, undamaged cartons, while non-sterile products must be in unused, saleable condition. Custom or special order products are not eligible for credit. Returns within ninety days from the ship date incur a 20% restocking charge.
Product Specifications:
The document lists various product specifications, including straight plates, curved plates, burr hole covers, and the KraniOS™ 1.6mm Cranial Closure System. Each product is identified by a catalog number and specification details.
Warranty Information:
Integra LifeSciences provides a one-year warranty for the Cusa Selector® Ultrasonic Surgical Aspirator, covering manufacturing defects under normal use. The warranty excludes defects from improper use, unauthorized repairs, and normal wear and tear. Service and repairs are categorized as in-warranty or out-of-warranty, with Integra responsible for in-warranty repairs.
Limitation of Liability:
Integra's liability is limited to repair or replacement of defective equipment. The warranty disclaims all other warranties, express or implied, including those of merchantability and fitness for a particular purpose. Integra is not liable for indirect, incidental, or consequential damages.
Warranty and Liability Limitations
The document outlines the warranty terms for Integra products, emphasizing that authorized distributors are not liable for incidental, indirect, consequential, or punitive damages related to product acquisition or use. The warranty excludes products repaired by unauthorized personnel or altered to affect stability or reliability. It disclaims all other warranties, express or implied, including merchantability or fitness for a particular purpose.

Force Majeure
Performance under the warranty may be excused due to uncontrollable events such as natural disasters, labor disputes, or government regulations. Parties must notify each other of such events.

Product Specifications
The document provides detailed specifications for the CUSA NXT and CUSA Selector systems, including console features, handpieces, and accessories. The CUSA NXT system is noted for its digital architecture and compatibility with MRI suites, while the CUSA Selector offers aspiration and irrigation control with various handpiece options.

Ordering and Return Policies
Pricing is firm for 30 days from quotation, with a minimum order requirement of $250. Returns require authorization, and products must be in unopened, undamaged condition. A restocking charge applies for returns within 90 days.

Service and Repairs
Warranty covers free service and maintenance for defects in materials and workmanship under normal use for one year. Exclusions include unauthorized repairs, improper use, and normal wear and tear. In-warranty repairs are provided by Integra or authorized representatives.
Integra Limited Warranty
Integra LifeSciences Corporation provides a one-year warranty for its products against manufacturing defects, applicable only to the original purchaser. The warranty covers defects in material and workmanship under normal use. Surgical instruments are guaranteed if maintained and used properly. Repairs during lease or rental agreements are covered as per the agreement terms. The warranty excludes liability for incidental or consequential damages and does not cover products altered or repaired by unauthorized personnel.
Pricing and Ordering Information
Prices are firm for 30 days from the quotation date and may change without notice. A minimum order of $100 is required, with a $10 handling charge for smaller orders. Shipping costs are prepaid by Integra and invoiced to customers. Orders require approval from Integra in Plainsboro, New Jersey.
Return Policy
Returns require prior authorization. Sterile products must be unopened and undamaged, while non-sterile products must be in saleable condition. Custom orders are non-returnable. Returns within 90 days incur a 20% restocking fee.
Integra NPH™ Low Flow Valve
This valve system offers position-independent performance without the need for programming, maintaining a constant drainage rate between 8 and 17 ml/hr. It is designed for patients requiring lower drainage rates and provides safety advantages over programmable valves.
OSV II® Valve Systems
The OSV II® Valve System uses a 3-stage mechanism to regulate CSF flow, minimizing risks of under or overdrainage. It includes a differential pressure valve, a flow-regulating valve, and a safety valve to restore normal ICP during pressure elevations.
Product Catalog
The document lists various configurations of the Integra NPH™ Low Flow Valve and OSV II® Valve Systems, including one-piece, two-piece, and three-piece systems with detailed specifications and catalog numbers for ordering.
CSF Valves and Shunt Kits Overview
This document provides detailed specifications and descriptions of various cerebrospinal fluid (CSF) valves and shunt kits offered by Integra LifeSciences. The products are designed for managing hydrocephalus by controlling the flow and pressure of CSF.

Product Specifications
  • OSV II® Systems: Available in one-piece and two-piece configurations, these systems include integral barium-striped ventricular and peritoneal catheters, connectors, and burr hole caps.
  • Equi-Flow™ Valve: Features a siphon limiting device to maintain physiological CSF pressure. It is available in regular and small sizes with various pressure levels (very low to high).
  • Novus™ Valve: Designed to mimic normal CSF physiology with an anti-siphon device. Available in standard and mini sizes, it includes a right-angle ventricular catheter guide.
  • Contour-Flex™ Valve: Utilizes a silicone membrane for pressure control, available in regular and small sizes, and includes a two-piece shunt system.
  • LPV II™ Valve: A low-profile diaphragm valve with a patented horizontal flow path, available in low, medium, and high-pressure ranges.

Performance and Features
  • Each valve system is designed to accommodate different patient needs with various pressure settings and configurations.
  • The valves are constructed to be compatible with imaging techniques like CT and MRI, ensuring no interference during scans.
  • Integral connectors and catheters are included to facilitate easy installation and maintenance.

Key Considerations
  • Selection of the appropriate valve and shunt system depends on the specific pressure requirements and anatomical considerations of the patient.
  • All systems are designed to minimize complications such as overdrainage and improper needle placement.
Overview: The document provides detailed information on various cerebrospinal fluid (CSF) valve systems and shunt kits designed for hydrocephalus management. It includes specifications, features, and configurations of different valve models such as LPV II™, Integra DP™, OMNISHUNT™, UltraVS™, and Pudenz Valves.
LPV II™ Valves: These valves feature a T-valve mechanism to reduce occlusion rates and are available in Standard and Mini sizes with three pressure ranges. They include integral connectors, an injectable domed reservoir, and radiopaque markings. The design excludes ferromagnetic parts, making them compatible with CT and MRI scans.
Integra DP™ Valve Systems: Known for their accurate pressure control and long-term reliability, these valves use a Ball-In-Cone and Spring mechanism. They are available in standard and pediatric versions with color-coded pressure ranges. Each system includes necessary components for implantation.
OMNISHUNT™ Valve Systems: Designed for pediatric and neonate patients, these systems offer a low-profile design with a single module ball-in-cone valve mechanism. They share the same pressure ranges as Integra DP™ and are designed for easy implantation.
UltraVS™ Valves: These valves have a cylindrical shape to reduce skin erosion risk and incorporate a miter valve mechanism. They are available in two sizes and three pressure ranges, with options for an integral Rickham-style reservoir for CSF sampling.
Pudenz Valves: Known for their reliability and variety, these valves include integral connectors and an Anti-Siphon Device. They feature an injectable reservoir for CSF sampling and distal flushing, with radiopaque pressure range indicators.
Key Features and Specifications: The document includes detailed specifications such as dimensions, pressure ranges, and catalog numbers for each valve type. It also highlights the importance of radiopaque markers for flow direction and pressure range identification.
Overview: The document provides detailed specifications and descriptions of various cerebrospinal fluid (CSF) valves and shunt kits, including Pudenz Valves, Mishler Dual-Chamber Valves, Multi-Purpose Valves, Lumbar-Peritoneal Shunts, and Anti-Siphon Devices. These medical devices are used for managing hydrocephalus and other conditions requiring CSF drainage.
Specifications:
  • Pudenz Valves: Available in 12mm and 16mm diameters, with pressure ranges categorized as low, medium, and high. They can be equipped with or without an anti-siphon device.
  • Mishler Dual-Chamber Valves: Feature integral connectors for catheter connection and allow for simultaneous or separate proximal and distal flushing. Available in low, medium, and high pressure ranges.
  • Multi-Purpose Valves: Include an on-off device for shunt dependency monitoring and ventricle decompression control. Available with or without an anti-siphon device, in three pressure ranges.
  • Lumbar-Peritoneal Shunts: Spetzler shunts are designed for treating communicating hydrocephalus in adults, featuring a double slit valve for pressure control. The kit includes a catheter, metal connector, Tuohy needle, and suture collars.
  • Anti-Siphon Devices: Designed to counteract the siphoning effect of hydrostatic pressure, maintaining appropriate pressure levels when the patient is upright.
Procedures and Recommendations:
  • Each valve and shunt system includes specific instructions for use, emphasizing the importance of following clinical guidelines for installation and maintenance.
  • Pressure ranges should be selected based on patient-specific factors such as ventricular enlargement and height.
  • Anti-siphon devices are recommended for preventing over-drainage in upright positions.
Performance and Testing:
  • Valves are tested for performance at various flow rates and pressure settings. The document includes charts illustrating flow/pressure ranges for different valve types.
  • MRI compatibility is confirmed for certain valve systems, indicating no significant changes in pressure settings post-exposure.
Contact Information: The document provides contact details for Integra LifeSciences, the manufacturer, for further inquiries and support.
Anti-Siphon Device
The Anti-Siphon Device is designed to minimize the siphon effect by closing as hydrostatic pressure changes relative to the patient's position. It can be connected in series with any flushing reservoir or proximal control valve using the provided connectors. This device is integral to many Integra valve systems.
CSF Reservoirs
The Integra Reservoir, formerly known as Ommaya, is a closed ventricular access system facilitating CSF withdrawal and delivery of therapeutic agents. It is available in various models to suit different treatment protocols and can be integrated into existing shunt systems. The reservoirs come with a small Pudenz ventricular catheter and have different styles and flushing volumes.
On-Off CSF Reservoirs
These reservoirs feature an exclusive On-Off Device and are available with or without an Anti-Siphon Device. They are designed with a reinforced flat bottom for stability.
Ventricular Catheters
Ventricular catheters are available in various configurations, including fully barium-impregnated for radiopacity or with a barium stripe. They come in straight or right-angled styles and are pressure-rated or non-pressure-rated. The catheters have radiopaque markers to aid in placement.
Shunt Implantation Instruments
Various instruments are available for shunt implantation, including catheter passers, introducers, and shunt tunnelers. These are available in disposable and reusable forms, with different lengths and materials to suit surgical needs.
Product Overview:
Integra LifeSciences offers a range of sterile, disposable medical accessories and devices, including Tuohy needles, subcutaneous tube passers, catheter connectors, guides, and introducers. These products are designed for use in various medical procedures, particularly in neurosurgery and shunt systems.
Specifications:
  • Tuohy Needle: Available in 14G, with lengths of 9cm and 15.2cm, featuring a thin wall and snap-on wings.
  • Plastic Subcutaneous Tube Passer: Made of polypropylene, suitable for F8 or 2.7mm OD tubes, 15cm in length.
  • Connectors and Guides: Include various types such as straight, right-angle, and three-way connectors made from nylon, silicone elastomer, and stainless steel.
Endoscopic Accessories:
The NeuroBalloon™ Catheter is designed for dilation of cerebral membrane fenestrations, featuring a double balloon for precise positioning. It is compatible with 4 French working channels and has a working length of 64cm.
Electrodes:
  • Cortical Strip Electrodes: Available with stainless steel or platinum contacts, designed for intracranial placement with a narrow cylindrical connector for secure attachment.
  • Cortical Grid Electrodes: Thin and flexible, available with up to 64 contacts, designed to conform to the cortical surface.
Warranty and Ordering Information:
  • Products are warranted to be free from manufacturing defects for one year under normal use.
  • Minimum order requirement is $100, with a $10 handling charge for orders under this amount.
  • Returns require authorization and must be in unopened, undamaged condition.
Overview: The document provides detailed specifications and ordering information for various types of electrodes and related equipment used in neurological procedures, particularly for epilepsy treatment. It includes product specifications, catalog numbers, and contact information for Integra LifeSciences.
Electrode Specifications: The document lists different types of electrodes, including cortical grid electrodes, depth electrodes, sphenoidal electrodes, and epidural peg electrodes. Each type is available with varying numbers of contacts, made from stainless steel or platinum, and different contact spacing options. The electrodes are designed for specific medical applications, such as recording brain activity or facilitating cortical stimulation.
Product Features: The electrodes are fabricated from high-quality materials like polyurethane tubing for durability and smoothness. They feature a cylindrical connector design for easy attachment and are available with implant-grade materials. The document also highlights the Ojemann Cortical Stimulator, a portable device used for cortical stimulation mapping.
Ordering and Warranty Information: The document outlines the ordering procedure, including minimum order requirements and return policies. It specifies that orders are accepted upon approval by Integra Customer Service. The warranty section details the terms under which Integra Neurosciences products are covered for manufacturing defects, emphasizing the conditions for repair or replacement.
Contact Information: The document provides contact details for customer service and technical support, including toll-free numbers and fax numbers for both domestic and international inquiries.
Warranty and Repairs
The document outlines the terms of warranty and repair services provided by Integra NeuroSciences. It distinguishes between 'in-warranty repairs' and 'out-of-warranty repairs,' with the latter incurring standard charges. The company's obligation is limited to adjustments and repairs as per the warranty terms. Replaced defective equipment becomes the property of Integra NeuroSciences, and refurbished parts may be used if functionally equivalent.

Equipment Replacement and Notification
Customers must notify Integra NeuroSciences immediately of any defects to avail warranty services. The company reserves the right to use refurbished parts for replacements.

Repair Parts and Services
The warranty includes modifications to covered equipment, which may involve new parts installation at the customer's expense. These modifications are subject to customer approval.

Quality Control
Customers are required to maintain quality control standards to avoid unnecessary maintenance. They must also assist in telephonic diagnosis of equipment malfunctions.

Limitation of Liability
The document disclaims all other warranties beyond those explicitly stated, including implied warranties of merchantability and fitness for a particular purpose. Integra NeuroSciences is not liable for any indirect or consequential damages beyond the amounts paid by the customer during the warranty period.

Force Majeure
Performance under the warranty may be excused due to uncontrollable events such as natural disasters, war, or regulatory changes.

Radionics CRW Stereotactic System
The Radionics CRW system is highlighted for its safety and accuracy in surgical applications like brain tumor biopsies and DBS implantation. It features a robust design with high tensile strength materials and offers software integration for comprehensive treatment planning.

Product Components and Accessories
The document details various components and accessories for the Radionics CRW system, including head rings, adapters, and imaging localizers. It provides specifications for each component, ensuring compatibility and functionality for surgical procedures.

Contact Information
Customer service and technical support contact details are provided for assistance with the Radionics CRW system and related products.
Overview: The document provides detailed specifications and components related to the Radionics® CRW® Stereotactic System, which is used in neurosurgical procedures. It includes information on reducing tubes, stereotactic system accessories, disposable components, and software for planning and execution of surgical procedures.
Specifications: The document lists various reducing tubes with specific inner diameters (I.d.) and lengths, compatible with guide tubes of 2.7mm I.d. These tubes are used to provide maximum access to surgical sites while maintaining trajectory and target settings.
System Components: The Radionics® CRW® System includes several components such as the Arc Hardware Kit, Quality Assurance Components, and Phantom Base System. These components are essential for ensuring accurate electrode placement and maintaining sterility during procedures.
Disposable Products: The document details disposable head ring screws and Nashold Biopsy Needles, which are sterile and designed for single use. These are crucial for maintaining sterility and precision during stereotactic procedures.
Software: The document describes various software tools like NeuroSight® Arc, ImageFusion™, AtlasPlan™, and StereoCalc™. These tools assist in trajectory planning, image correlation, and target confirmation, enhancing the accuracy and efficiency of neurosurgical procedures.
Training and Manuals: User manuals for the Radionics® CRW® System and associated software are available, providing guidance on the use and application of the system and its components.
See more

Catalog excerpts

Neuro Operating Room-2

DuraGen, DuraGen Plus, NeuraGen, Helitene, BUDDE, CUSA, CUSA EXcel, Selector, OSV II, Radionics, CRW, NeuroSight, OmniSight and Luminant are registered trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States and/or other countries. The Integra wave logo, Suturable DuraGen, NeuraWrap, Ultra360, KraniOS, CUSA NXT, Sheartip, SaberTip, MicroTip, MicroTip Plus, CEM, Integra NPH, OSV II Low Pro, Equi-Flow, Novus, Contour-Flex, LPV II, Integra DP, Omnishunt, UltraVS, Mishler, Spetzler, Integra, NeuroBalloon, NeuroView, Integra Epilepsy, AtlasPlan, StereoCalc and ImageFusion...

 Open the catalog to page 2
Neuro Operating Room-6

Advanced Biomaterials

 Open the catalog to page 6
Neuro Operating Room-7

Ordering and Warranty Information Pricing: Prices stated in specific written quotations are firm for thirty days from the date given, and are otherwise subject to change without prior notice. Pricing terms stated on written agreements are governed by such agreements. Minimum Order Requirements: Minimum order requirement is $100 (a $10 handling charge will be added to any order under $100). For partial case orders, contact the Customer Service Department for quotation. Shipments: F.O.B. Integra NeuroSciences point of shipment within the continental United States. Shipping costs (including freight...

 Open the catalog to page 7
Neuro Operating Room-8

Dural Repair DuraGen XS™ Dural Regeneration Matrix DuraGen XS™ Dural Regeneration Matrix is Integra’s most advanced onlay graft. DuraGen XS Dural Regeneration Matrix is an absorbable implant that is indicated as a dural substitute for repair of dura mater. DuraGen XS benefits from 30% more collagen, which provides increased tensile strength and more robust handling over DuraGen Plus. After implantation, DuraGen XS is infiltrated by fibroblasts and is fully resorbed and replaced with endogenous tissue. DuraGen XS is manufactured from Ultra Pure Collagen™, handles and conforms similar to normal...

 Open the catalog to page 8
Neuro Operating Room-9

Dural Repair Suturable DuraGen™ Dural Regeneration Matrix Suturable DuraGen™ Dural Regeneration Matrix is Integra’s reinforced onlay graft. It is a suturable, resorbable, onlay graft indicated as a dural substitute for the repair of dura mater. The stronger integrated-matrix design combines suturability while maintaining the biological activity of DuraGen Plus. After implantation, Suturable DuraGen is infiltrated by fibroblasts and is fully resorbed and replaced with endogenous tissue. Suturable DuraGen conforms similar to normal soft tissue and has an excellent safety profile. Single Unit Single...

 Open the catalog to page 9
Neuro Operating Room-10

Nerve Conduit/Wrap NeuraGen® Nerve Guide NeuraGen® Nerve Guide is for the repair of peripheral nerves which have been completely severed. NeuraGen Nerve Guide is a semi-permeable collagen tube that isolates and provides an environment for the extension of axons and growth of Schwann cells that are the elements responsible for functional recovery following nerve injury. Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit Single Unit NeuraWrap™ Nerve Protector NeuraWrap™ Nerve Protector is for the protection...

 Open the catalog to page 10
Neuro Operating Room-11

Hemostatic Agent Helitene® Absorbable Collagen Hemostatic Agent-Fibrillar Form Helitene® Absorbable Collagen Hemostatic Agent is a soft, white, pliable, absorbent fibrillar hemostatic agent. Helitene is indicated in surgical procedures (other than ophthalmological and urological surgery) as an adjunct to hemostasis when control of bleeding by ligature or conventional procedures is ineffective or impractical.

 Open the catalog to page 11
Neuro Operating Room-12

Cranial Stabilization and Brain Retraction

 Open the catalog to page 12
Neuro Operating Room-13

Ordering and Warranty Information Pricing: Prices are as listed in the Integra LifeSciences Corporation current price list and are subject to change without notice. Prices stated in specific written quotations are firm for 60 days from the date given, and are otherwise subject to change without prior notice. Pricing terms stated on written agreements are governed by such agreements. Minimum Order Requirements: Minimum order requirement is one unit unless otherwise noted. Shipments: F.O.B. Integra point of shipment within the continental United States. Shipping costs (including freight and insurance),...

 Open the catalog to page 13
Neuro Operating Room-14

Skull Clamps and Headrest Systems MAYFIELD® Infinity Skull Clamp Provides 3-point rigid cranial fixation. • Added length and curved contours of the skull clamp uprights Multiple rocker arm options-Standard, Triad, Pediatric, Single-Pin 80lb and 18lb Torque Screw Options MAYFIELD® Modified Skull Clamp Provides 3-point rigid cranial fixation. • Flexibility and safety in positioning of skull pins around critical areas Quick-release lock MAYFIELD® 2000 Skull Clamp Provides 3-point rigid cranial fixation. • Streamlined body design and low profile single pin side facilitates greater exposure to the...

 Open the catalog to page 14
Neuro Operating Room-15

Skull Clamps and Headrest Systems MAYFIELD Triad™ Skull Clamp Provides 3-point rigid cranial fixation. • Provides visual indication of clamping force on ALL THREE skull pins Ability to adjust the force on ALL THREE skull pins Equal impingement of pins ensures firm skull positioning and fixation MAYFIELD® Adult Horseshoe Headrest Horseshoe shaped headrest provides cranial support in the prone or supine position for adults and older children. • Vertical and lateral adjustments allow flexibility in patient positioning Connects directly to the Transitional member for chin-to-chest positioning Adjustable...

 Open the catalog to page 15
Neuro Operating Room-16

Skull Clamps and Headrest Systems MAYFIELD® Pediatric Horseshoe Headrest Horseshoe shaped headrest provides cranial support in the prone or supine position for infants and young children. • Vertical and lateral adjustments allow flexibility in patient positioning Adjustable pad base accommodates various head sizes Fluid resistant gel pads provide comfort and reduce the incidence of pressure necrosis Easily cleaned MAYFIELD® General Purpose Headrest Provides cranial support and positioning when rigid fixation is not needed. • Headrest pads easily contour to a patient’s head Papadopoulos Posterior...

 Open the catalog to page 16

All Integra LifeSciences catalogs and technical brochures

  1. cadence

    4  Pages

  2. transducer

    2  Pages

  3. MAYFIELD®

    12  Pages

  4. SurgiMend®

    6  Pages

  5. DuraGen XS

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.