Overview: The document provides detailed specifications and features of the Intelsint ETP and EFTP vacuum tissue processors, designed for histology laboratories. These processors are noted for their safety, reliability, and advanced features, catering to daily tissue processing needs.
Specifications:
  • ETP Model: Processes up to 360 specimens, includes three paraffin containers, and features an easy-to-use Human Machine Interface (HMI).
  • EFTP Model: Capable of processing up to 450 biopsies in 45 minutes using traditional or substitute reagents. It features the Enhanced Heat Exchanger (EHE) for efficient reagent heating.
Key Features:
  • Both models include a vacuum tissue processor with handling wheels and brakes, a 15” color touch screen HMI, and a processing capacity of up to 450 cassettes.
  • Equipped with 10 reagent tanks, 3 paraffin containers, and a sample processing chamber with a fume aspiration system.
  • Reagent Management System (RMS) and Remote Fill and Drain (RFD) for easy reagent management.
  • Advanced safety features including active carbon filters for formaldehyde filtration and multiple programmable processing protocols.
Optional Features:
  • PLUSM reagent identification system with RFID/NFC technology for error prevention in reagent management.
  • External UPS for safe reagent recovery during power failures.
  • Connectivity options with Laboratory Information Systems (LIS) for sample and reagent tracking.
Technical Specifications:
  • Processing pressures range from 600 to 1200 Hpa, with a reagent temperature range of 20-65°C and paraffin temperature range of 55-65°C.
  • Equipped with a touch screen monitor, USB ports, and network ports for data transfer and remote control.
  • Complies with CE, CTUVus, UL, IEC, and CAN/CSA standards.
Dimensions and Weight: The ETP model measures 680 x 700 x 1500 mm and weighs 198 kg, while the EFTP model weighs 226 kg.
See more

Catalog excerpts

ETP / EFTP - VACUUM TISSUE PROCESSORS-1

VACUUM PROCESSATORI TISSUE SOTTOVUOTO PROCESSORS

 Open the catalog to page 1
ETP / EFTP - VACUUM TISSUE PROCESSORS-2

Fully enclosed, “state of the art” features, safe and highly reliable, the Intelsint ETP is the right answer for the day-by-day tissue processing needs of every Histology laboratory. With a processing capacity of 360 specimens, three paraffin containers and an easy to operate HMI (Human Machine Interface) it sets itself at the top of the category. Designed with specimens safety and operator ergonomics in mind, the ETP is also capable of performing in unfavorable enviroments. Its fully automated RFD (Remote Fill and Drain) feature allows the user a safe, clean and easy reagents renewal. Simple...

 Open the catalog to page 2
ETP / EFTP - VACUUM TISSUE PROCESSORS-3

General characteristics of ETP and EFTP models (906003 – 906004) √ Vacuum tissue processor for histological samples, with handling weels with brakes Management of: vacuum / pressure, heating and agitation of the reagent 3 paraffin containers 4 liters each 2 reagents tanks for purge cycle 5 liters each HMI system ( Human Machine Interface ) with 15” colour touch screen high definition Processing capacity : up to 450 standards cassettes 10 reagents tanks 5 liters each Sample processing chamber with fume aspiration system Heating system for processing chamber lid to avoid condensation Processing...

 Open the catalog to page 3
ETP / EFTP - VACUUM TISSUE PROCESSORS-4

Sample Processing Chamber for histological samples: 3 paraffin melting chambers, capacity 5 Lt each • Up to 450 cassettes loading capacity • Made entirely of AISI 316 stainless steel with special surface treatment for fast cleaning • Gas piston for easy opening • Open/close detection sensor • 3 Level Sensors • Overfill pneumatic sensor HMI with touch screen and high definition 15“ color LCD display Processing Chamber opening handle USB port for software update and data saving Fast connectors for RFD and EWD fill and drain system Trasparent doors to protect the processing reagents Handling wheels...

 Open the catalog to page 4
ETP / EFTP - VACUUM TISSUE PROCESSORS-5

PLUS system for identification of reagents with RFID / NFC technology (Option 906030) The only tissue processor capable to prevent errors during the management/substitution of the processing reagents. A software procedure guides the operator during reagent maintenance, informing when it is necessary to replace the reagent for exceeding the limits set by the operator. The exclusive system equipped with 12 RFID / NFC sensors physically checks the presence / absence of each reagent tank and in the case of use of factory-prefilled reagents, it is also possible to check the type of reagent present...

 Open the catalog to page 5
ETP / EFTP - VACUUM TISSUE PROCESSORS-6

Tissue processor configuration EFTP Fast Tissue Processor 360/450 samples (Code: 906004) ETP Vacuum Tissue Processor 360/450 samples (Code: 906003) PLUSM Plus module: integration with RFiD/NFC system for each reagent tank (12 sensors) (Code 906030) ALTERNATIVELY BRSW + BRG Barcode reader software (for reagent and/or basket identification) (Code 906060) Barcode reader gun (Code: 3BCR01) OLIS Connection with LIS system (Code: 906059) RSSW Remote Service software Licence (Code: 906061)

 Open the catalog to page 6
ETP / EFTP - VACUUM TISSUE PROCESSORS-7

Process Editing Simple Clear Easy Intuitive 18 Process available Drag & Copy Function Copy Process Function Controlled Field Value Process Start and Run Most Used Process Function Easy End of Process Setting Reagent Level Check Partial Reagent Load Samples Baskets Check Info Function to check ‘at a glance’ the most important instrument parameters Reagent Quality Check Remote Fill & Drain To change the reagents easily without removing tanks Reagent Quality Check Easy and Intuitive HMI RFD connected with RMS Fast and Fully Automated 2 Ports for Reagents 1 Port for Paraffin Operator management with...

 Open the catalog to page 7
ETP / EFTP - VACUUM TISSUE PROCESSORS-8

Sample Processing Capacity Sample baskets Load capacity for histological samples SPC Level Sensors EHE for Fast Processing Protocols features Processing Programs Prefered programs, with quick start Purge programs Reverse Processing Special Program Maximum time for each step Start process maximum dalay Process End time/date Reagents User programmable Processing reagents Process chamber washing reagents Paraffin Containers Reagents Temperature Range Paraffin Temperature Range Processing pressures RMS - Reagent Management System RFD - Remote Fill & Drain Vapor treatment Charcoal filter Safe reagents...

 Open the catalog to page 8