Overview: The Scan® 1200 is an advanced automatic colony counter designed for high-resolution color imaging and adaptability across various laboratory media. It offers high accuracy, reproducibility, and automatic image and result saving.
Specifications: The device features a stainless steel body, HD CCD color camera, and Japanese lens with a zoom of x28. It supports white LED lighting with multiple combinations and has a resolution of 1.2 megapixels. The system can count up to 1000 colonies per second and detect colonies as small as 0.05 mm.
Counting Capabilities: The Scan® 1200 can count colonies on various plating methods including pour, surface, Spiral®, circle, chromogenic dishes, and more. It also supports automatic separation of clustered colonies and creation of exclusion zones.
Inhibition Zone Reading: The device functions as an inhibition zone reader, suitable for pharmaceutical, medical, and veterinary applications. It can read up to 7 antibiotic disks on a 90 mm Petri dish with a reading time of 1 to 3 seconds.
Technical Features: The system supports multiple languages and offers data export in various formats including PDF, jpg, png, and Excel™. It is compatible with dataLink™ systems for enhanced traceability and conforms to 21 CFR part 11 for data security.
Power and Dimensions: The device operates on 100-240 V with a maximum power of 20 W. It measures 28.8 x 26.3 x 37.3 cm and weighs 9.4 kg.
Warranty and Compliance: The Scan® 1200 comes with a 3-year warranty and software updates. It is manufactured under CE, UKCA, RoHS, and WEEE standards and complies with ISO 7218 and AOAC 977.27.
Minimum Computer Requirements: Requires an Intel i5 processor, Windows™ 10 or 11, 4 GB RAM, and a screen resolution of 1280 x 1024 pixels.
Included Accessories: The package includes Scan® software, power cord, USB cable, validation plates, and a user manual. Optional accessories include adapters for various media and a barcode reader.
See more

Catalog excerpts

Scan 1200 technical file-1

Traceability and High technology: Manufactured under: Scan® 1200 is a high-resolution color automatic colony counter, that enables an adaptability to all media in labs and a great user comfort with high accuracy, an excellent reproducibility and automatic saving of images and results. • Counting on pour plating • Counting on surface plating • Counting on Spiral® plating • Counting on circle plating • Counting on chromogenic dishes • Counting on PetriRlm™, MC-Media PadsTM, Compact Dry™, easyPlate™, filtration membranes • Automatic separation of clustered colonies • Creation of polygonal exclusion zones Additional Standards: XFI irAQT rsrr l_ U/lU I SUSCEPTIBILITY TESTING European Society of Clinical Mlcrobloloiy and Infectious Diseases Scan® 1200 is an inhibition zone reader and automatic colony counter. It has been designed for the pharmaceutical industry, medical research, and animal health. • Inhibition zone reading on round dishes 0 90 mm • Automatic detection: paper disks (several brands simultaneously), wells, peni-cylinder (steel, plastic) with possibility to add or remove manually • Number of antibiotic paper disks: up to 7 antibiotics on a 0 90 mm Petri dish • Reading time: 7 inhibition zone reading between 1 to 3 seconds • Interpretation system: EUCAST / CA-SFM Human health / CA-SFM Veterinary / CLSI (Clinical, Laboratory Standards Institute) / customizable list • Inhibition zone measurement accuracy: ± 0,3 mm • Display resolution: ± 0.1 mm

 Open the catalog to page 1
Scan 1200 technical file-2

TECHNICAL SPECIFICATIONS • • • • • • • • All stainless steel body HD CCD color camera HD japanese lens Zoom x 28 Resolution: 1.2 megapixels White LED lighting technology: Dark Field Lighting system: automatic 6 combinations, top and/or bottom light, white or black background Languages: French, English, Japanese, Chinese, Russian, Spanish, German Counting time: up to 1000 colonies per second Minimum size of colony: 0.05 mm Counting: automatic with manual control Counting Petri dishes Ø 55 - 90 mm Manual control to add or subtract colonies Counting on 100% of the Petri dish Color detection: 7 colors...

 Open the catalog to page 2
Scan 1200 technical file-3

MINIMUM COMPUTER REQUIREMENTS • • • • • Processor: Intel i5, 2.8 GHz, quad core (or higher) Operating system: WindowsTM 10 or 11 (or higher) RAM: 4 Gb for the exclusive use of the Scan® Equipment: 1 USB port free (4 recommended) Screen resolution: 1280 x 1024 pixels (or higher) DELIVERED WITH • • • • • 1 Scan® software 1 15 V power cord 1 USB cable 3 validation plates 1 user manual OPTIONS / ACCESSORIES • • • • • • • • • dataLink™: traceability system for Petri dishes, from plating to counting, using label printing Stickers for printer: Labels roll for thermal printer - Label size: 45 x 10 mm...