Overview: The Scan® 500 is an automatic colony counter and inhibition zone reader designed for use in pharmaceutical industries, medical research, and animal health. It offers quick and efficient counting of colonies on various plating methods and provides excellent reproducibility with automatic image and result saving.
Specifications:
  • Counting capabilities include pour plating, surface plating, Spiral® plating, circle plating, and chromogenic dishes.
  • Automatic separation of clustered colonies and creation of polygonal exclusion zones.
  • Inhibition zone reading on round dishes Ø 90 mm with automatic detection of paper disks, wells, and peni-cylinders.
  • Antibiogram reading accuracy of ± 0.3 mm with automatic and manual correction capabilities.
  • Stainless steel body, CMOS color camera, M12 lens, and zoom x 28 with a resolution of 1 megapixel.
  • Lighting technology includes long-life white LEDs and Dark Field with automatic lighting combinations.
  • Counting time of up to 1000 colonies per second with a minimum colony size of 0.1 mm.
  • Data export options include PDF, jpg, png, bmp images, and Excel™ recountable sessions.
  • Compatible with dataLink™ or dataLink™ pro traceability systems and LIMS/SIL connection.
  • Data security in conformity with 21 CFR part 11.
  • Voltage and frequency: 100-240 V ~ 50-60 Hz, Max power: 20 W.
  • Dimensions: 28.7 x 27.1 x 29 cm, weight: 8.38 kg.
  • 3-year warranty with software updates and spare parts availability for 10 years.
  • Compliance with 21 CFR part 11, ISO 7218, and AOAC 977.27.
System Requirements:
  • Processor: Intel i5, 2.8 GHz, quad core or higher.
  • Operating system: Windows™ 10 or Windows™ 11 (or higher).
  • RAM: 4 Gb for exclusive use of the Scan®.
  • Screen resolution: 1280 x 1024 pixels or higher.
Included Accessories:
  • 1 Scan® software, 1 15 V power cord, 1 USB cable, 3 validation plates, 1 user manual.
  • Various references for dataLink™ systems, stickers, films, and adaptors for Petri dishes.
See more

Catalog excerpts

Scan 500 technical file-1

Scan® 500 Ref 436 000 Automatic colony counter Standards: Traceability and High technology: Dartt Field C€ UK Cfi Scan® 500 is an automatic color colony counter providing quick and efficient counting of the colonies on the most common supports. Scan® 500 guarantees an excellent reproducibility and the automatic saving of images and results. • Counting on pour plating • Counting on surface plating • Counting on Spiral® plating • Counting on circle plating • Counting on chromogenic dishes • Automatic separation of clustered colonies • Creation of polygonal exclusion zones Inhibition zone reader Additional Standards: Xr I I P A f12 T EUROPEAN COMMITTEE HIM Zl ^ | ON ANTIMICROBIAL I— U U IT U I SUSCEPTIBILITY TESTING European Society of Clinical Microbiology and Infectious Diseases Scan® 500 is an inhibition zone reader and automatic colony counter. It has been designed for the pharmaceutical industries, medical research and animal health. • Inhibition zone reading on round dishes 0 90 mm • Automatic detection: paper disks (several brands simultaneously), wells, peni-cylinder (steel, plastic) with possibility to add or remove manually • Number of antibiotic paper disks: up to 7 antibiotics on a 0 90 mm Petri dish • Reading time: 7 inhibition zone reading between 1 to 3 seconds Interpretation system: EUCAST / CA-SFM Human health / CA-SFM Veterinary / CLSI (Clinical, Laboratory Standards Institute) / customizable list • Antibiogram reading accuracy: ± 0,3 mm • Inhibition zone measurement: automatic with manual correctio

 Open the catalog to page 1
Scan 500 technical file-2

TECHNICAL SPECIFICATIONS • All stainless steel body • CMOS color camera • M12 lens • Zoom x 28 • Resolution: 1 megapixel • Lighting technology: long-life white LEDs / Dark Field • Lighting system: automatic 6 combinations, top and/or bottom light, white or black background • Languages: French, English, Japanese, Chinese, Russian, Spanish, German • Counting time: up to 1000 colonies per second • Minimum size of colony: 0.1 mm • Counting: automatic with manual control • Counting Petri dishes 0 55 - 90 mm • Manual control to add or substract colonies • Color detection: 7 colors on the same dish...

 Open the catalog to page 2
Scan 500 technical file-3

MINIMUM COMPUTER REQUIREMENTS • Processor: Intel i5, 2.8 GHz, quad core or higher • Operating system: Windows™ 10 or Windows™ 11 (or higher) • RAM: 4 Gb for the exclusive use of the Scan® • Equipment: 4 USB ports free • Screen resolution: 1280 x 1024 pixels or higher DELIVERED WITH • 1 Scan® software • 1 15 V power cord • 1 USB cable • 3 validation plates • 1 user manual Ref 410 100 dataLink”: traceability system for Petri dishes, from plating to counting, using label printing Ref 410 120 Stickers for printer: Labels roll for thermal printer - Label size: 45 x 10 mm Ref 410 130 Film: Thermal...

 Open the catalog to page 3

All INTERSCIENCE catalogs and technical brochures

  1. Scan® 100

    4  Pages

  2. easySpiral®

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.