Catalog excerpts

PHL - 1

Implants trauma Proximal Humeral Locking Plate

Open the catalog to page 1
PHL - 2

CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or...

Open the catalog to page 2
PHL - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Assembling of the percutaneous guide P. 10 Pre-operative patient preparation P. 11 Exposure P. 11 Reduction P. 12 Plate insertion P. 13 Intraoperative identification of screw length P. 14 Placement of the screws P. 18 Disassembling of the percutaneous guide P. 19 Optional fixation of soft tissue P. 19 Optional fixation in the shaft area with cerclage P. 19 Postoperative treatment P. 19 Explantation 3. Information P. 21 Locking P. 21 Dotize® P. 22...

Open the catalog to page 3
PHL - 5

Preface The newly developed Proximal Humeral Locking Plate enables the medical treatment of fractures in the joint area with an optional less invasive method. The special feature of this implant is the free choice of screw placement. The user is able to set any desired screw in any hole (except oblong hole). Especially with complex fractures the free choice of screw angle (+/- 15°, see page 21) has advantages in the fracture treatment.

Open the catalog to page 5
PHL - 6

Cortical Screw, Locking, D=3.5mm, SH Spiral Drill, D=2.7mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Cortical Screw, D=3.5mm Spiral Drill, D=2.7mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Cancellous Screw, locking, D=4.2mm, SH Spiral Drill, D=2.5mm, L=220mm, AO Connector Screwdriver, WS 2.5, self-holding Guide Wire, Steel, D = 1.6mm, L=260mm, TR, w. thread

Open the catalog to page 6
PHL - 7

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Anatomical plate design • 6 proximal plate holes for optimal reconstruction of the humeral head • Oblong hole for optimal positioning and adjustment of the humeral length • K-Wire holes for preliminary plate fixation • Pointed distal plate end for percutaneous insertion • Lengths: 4, 7,...

Open the catalog to page 7
PHL - 8

Indications, Contraindications & Time of operation Indications: • All stable and unstable fractures with or without shaft involvement Severe osteoporosis Existing infections in the area of the fracture In cases of skin and soft tissue problems Obesity Lack of patient compliance Time of operation: • Primary as well as secondary after swelling subsides and after temporary

Open the catalog to page 8
PHL - 9

Surgical Technique

Open the catalog to page 9
PHL - 10

Assembling of the percutaneous guide 1 Pre-operative patient preparation • Positioning on a radiolucent surgical table • Semi-sitting angle of about 30° - 40°, shoulder should be freely moveable (optional shoulder table) • The arm should be freely moveable to allow fracture reduction • General anaesthesia, regional anaesthesia or combination can be u

Open the catalog to page 10
PHL - 11

Exposure Anterolateral access: • Skin incision parallel to the anterior acromion and extension 5cm distally in fiber direction of the M. deltoideus. • Detachment of the pars acromialis of the M. deltoideus. Reduction Anatomical reduction of the fracture under fluoroscopy.

Open the catalog to page 11
PHL - 12

Plate insertion • • • • Insert the plate, assembled on the percutaneous guide (recommended in Z position) Plate remains in constant contact with the bone and slide distally Align the proximal end of the plate on the Tuberculum majus Verify the correct plate position. Optional temporary fixation with guide wires, steel, D=1.6mm, L=260mm, TR, w. thread (35164-260) into proximal guide wire h

Open the catalog to page 12
PHL - 13

Intraoperative identification of screw length 1. Insert the depth gauge for humeral systems (59222) after drilling screw holes. Then, hook into the far medial cortices and read off the required screw length. 2. Drill screw holes under fluoroscopy guidance through the far medial cortices. Then, read off the required screw length at the calibrated spiral drill D=2.7mm, L=220mm (61273-220). Note: In the proximal area, the screw length is determined using the depth gauge, solid small fragment screws (59022).

Open the catalog to page 13
PHL - 14

Placement of the screws Fix the plate temporarily to the bone and drill with the spiral drill, D=2.7mm, L=220mm, AO Connector (61273-220) in the oblong hole. Drilling is performed through the D=2.8mm drill sleeve (118005-10) that was placed in the tissue protection sleeve (118005-8). Then, the drill sleeve is removed and a D=3.5mm cortical screw (32351-XX) (appropriate length measured before) is inserted through the tissue protection sleeve. Advice: For optimal positioning and adjustment of the humeral length, we recommend to first fill the oblong hole. Therefore there is a centric and...

Open the catalog to page 14
PHL - 15

Unscrew the clamping nut (118005-4) up to the black mark (see picture below), rotate the handle 180° and tighten the clamping nut by hand. Then using the spiral drill, D=2.5/2.7mm, L=220mm, AO Connector (61253-220/61273-220) to drill through the drill guide, D=2.7/2.0mm (62202) into a proximal hole. Use the screwdriver, WS 2.5 (56252-150) to insert a D=3.5mm locking cortical screw (37351XX-N) or a D=4.2mm locking cancellous screw (37422-XX-N) of appropriate length determined previously with the depth gauge, solid small fragment screws (59022).

Open the catalog to page 15
PHL - 16

Following unscrew the clamping nut (118005-4) up to the black mark (see picture below), rotate the handle 180° and tighten the clamping nut by hand. Then the shaft holes are occupied, optionally with locking or non-locking screws. Use the screwdriver, WS 2.5 (56252-150) to insert D=4.2mm locking cancellous screws (37422XX-N) or D=3.5mm cortical screws, optionally locking or non-locking (32351-XX/37351XX-N) of appropriate lengths determined previously.

Open the catalog to page 16

All I.T.S. catalogs and technical brochures

  1. ufs

    1 Pages

  2. DHL

    2 Pages

  3. ITS

    2 Pages

  4. ACLS

    20 Pages

  5. CFN

    32 Pages

  6. OLS

    24 Pages

  7. PHLs

    20 Pages

  8. SR Sacral Rods

    20 Pages

  9. HCS

    24 Pages

  10. TLS

    20 Pages

  11. PRS-RX

    32 Pages

  12. HLS

    20 Pages

  13. ES

    20 Pages

  14. SR

    20 Pages

  15. FL

    24 Pages

  16. CAS

    40 Pages

  17. FCN

    20 Pages

  18. HOL

    24 Pages

  19. FLS

    24 Pages

  20. PFL

    20 Pages

  21. DTL

    24 Pages

  22. HTO

    24 Pages

  23. PTL

    32 Pages

  24. DFL

    32 Pages

  25. SCL

    32 Pages

  26. SLS

    24 Pages

  27. CAL

    20 Pages

  28. DUL

    24 Pages

  29. CLS

    28 Pages

Archived catalogs

  1. SR Old

    20 Pages

  2. ES Old

    20 Pages

  3. CAS Old

    36 Pages

  4. CS

    16 Pages

  5. SN Old

    16 Pages

  6. FCN Old

    16 Pages

  7. DFL Old

    28 Pages

  8. FTN

    12 Pages

  9. PRS

    28 Pages

  10. PRL

    28 Pages

  11. UOL

    32 Pages

  12. SL

    16 Pages

  13. OHL

    24 Pages

  14. OL

    16 Pages

  15. DHL

    16 Pages

  16. PHL

    16 Pages

  17. CLS

    24 Pages