PHLs

Product catalog summary
Introduction
The Proximal Humeral Locking Plate Small is designed for treating joint area fractures, offering flexible screw placement with a choice of screw angle (+/- 15°), beneficial for complex fractures.
Specifications
- Plate Material: Titanium
- Screw Material: TiAl6V4 ELI
- Plate Lengths: 3, 4-hole
- Properties: Multi-directional locking, anatomical design, improved fatigue strength, reduced risk of cold welding and inflammation.
Indications & Contraindications
Indications: Dislocated, unstable 2, 3, and 4-segment fractures, valgus-impacted 4-segment fractures, non-union of the humeral head.
Contraindications: Diaphyseal fractures, existing infections, obesity, lack of patient compliance.
Surgical Technique
- Pre-operative: Beachchair position, fluoroscopy from head end.
- Procedure: Deltopectoral access, temporary fixation with drill wires, positioning and fixation of the plate with cortical screws, optional refixation of fragments.
- Postoperative: Early functional movement, shoulder bandage if bone quality is poor.
- Explantation: Possible after 1.5 years or upon bone healing verification.
Information
Dotize® Technology: Anodization Type II enhances implant surface, reducing inflammation risk and improving fatigue resistance.
Locking Mechanism: Allows for ± 15° adjustment, no pre-threading required, and screws can be reset up to three times.
Reconditioning Manual
- Implants are single-use; instruments are reusable with proper cleaning and sterilization.
- Sterilization: Steam (damp heat) recommended.
- Cleaning: Use soft brushes, avoid metal brushes to prevent surface damage.
- Automatic cleaning/disinfection is preferred, with specific guidelines for temperature and cleaning agents.
Warnings and Precautions
- Regular follow-up examinations are necessary.
- Do not combine implants from different manufacturers.
- MRI use with steel implants is prohibited.
- Handle contaminated products with care, using appropriate protective measures.
Cleaning and Disinfection Procedures
Use cleaning agents/disinfectants from the VAH list, such as Sekusept® Aktiv 2% by ECOLAB. Ensure powdered products are fully dissolved before use. Avoid highly alkaline or acidic additives; recommended pH range is 4.5 - 10.5. Prepare solutions fresh daily. For ultrasound treatment, immerse instruments for 5 minutes, then leave in solution for 15 minutes. Rinse thoroughly with tap water, paying attention to hard-to-reach areas, and dry immediately using a lint-free cloth or air gun.
Manual Disinfection
If using a non-disinfectant cleaning agent, perform separate disinfection. Follow manufacturer’s instructions for concentration, temperature, and exposure time. Use authorized disinfectants from the VAH list.
Inspection and Maintenance
Inspect each instrument for cleanliness and repeat cleaning if necessary. Lubricate movable mechanisms with authorized lubricants. Ensure movable parts function correctly and reassemble easily.
Packaging and Sterilization
Packaging is for transport only; follow hospital procedures for sterilization. Use fractionated pre-vacuum sterilization per EN 285 or EN 13060 and EN ISO 17665. Recommended steam sterilization parameters: 134°C for 5 to 18 minutes.
Disposal and Responsibility
Follow hospital guidelines for disposal. Instruments returned to I.T.S. GmbH must be cleaned, disinfected, inspected, and sterilized, with decontamination confirmation.
Important Information
Instructions are validated for reconditioning medical devices. Reconditioners must ensure processes achieve desired results through validation and routine inspections. Contact I.T.S. GmbH for questions.
Patient Information
Patients should be informed about post-implantation behavior and the importance of reporting any negative changes or accidents.
Symbols and Standards
Includes symbols for prescription, single use, expiry date, sterilization methods, and compliance with standards like ISO 13485 and ISO 17664.
See more

Catalog excerpts

PHLs-1

Implants trauma Proximal Humeral Locking Plate Small

 Open the catalog to page 1
PHLs-2

CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent...

 Open the catalog to page 2
PHLs-3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Proximal Humeral Locking Plate Small 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Surgical Technique P. 11 Postoperative treatment P. 11 Explantation 3. Information P. 13 Locking P. 13 Dotize® P. 14 Order list P. 16 Reconditioning Manual P. 18 Notes

 Open the catalog to page 3
PHLs-5

o Preface The Proximal Humeral Locking Plate Small enables the medical treatment of fractures in the joint area. The special feature of this implant is the free choice of screw placement. The user is able to set any desired screw in any hole (except oblong hole). Especially with complex fractures the free choice of screw angle (+/- 15°, see page 13) has advantages in the fracture treatment.

 Open the catalog to page 5
PHLs-6

Cortical Screw, Locking, D=3.5mm, SH Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Cortical Screw, D=3.5mm Spiral Drill, D=2.7mm, L=100mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Cancellous Screw, locking, D=4.2mm, SH Spiral Drill, D=2.5mm, L=180mm, AO Connector Screwdriver, WS 2.5, self-holding sleeve Guide Wire, Steel, D=2.0mm, L=228mm, TR

 Open the catalog to page 6
PHLs-7

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy Multi-directional locking Anatomical plate design Optimal reconstruction of the joint Easy adjustment due to oblong hole Plate lengths: 3, 4-hole

 Open the catalog to page 7
PHLs-8

Indications & Contraindications Indications: • Dislocated, unstable 2, 3 and 4-segment fractures of the humeral head • Valgus-impacted 4-segment fractures of the humeral head • Non-union of the humeral head Diaphyseal fractures of the humeral head Existing infections in the fracture zone and operation area Common situations that do not allow osteosynthesis Obesity Lack of patient compliance Proximal Humeral Locking Plate Small Fractures of the humeral head amount to 5% of all fractures and at least 45% of all humerus fractures. Whereas severe injuries with considerable trauma predominate in younger...

 Open the catalog to page 8
PHLs-9

Surgical Technique

 Open the catalog to page 9
PHLs-10

Pre-operative patient preparation • Beachchair position • Adjustable accesory table to support arm position • Fluoroscopy from the head end Surgical Technique • • • • • • • • • Deltopectoral access Raising the calotte fragment with reduction onto the shaft fragment (fig.1) Temporary fixation of the reduction using drill wires (fig.2) Position the humeral plate 5mm distal to the proximal end of the tuberculum majus and 10mm dorsal to the posterior edge of the intertubercular groove and fixation of the humeral head plate by means of a cortical screw in the sliding hole Fixation of the humeral head...

 Open the catalog to page 10
PHLs-11

Postoperative treatment • Functionally as early as possible • If bone quality is bad, shoulder bandage for a maximum of 4 weeks • Passively and actively guided movement exercises Explantation If desired by the patient, the implant can be removed. Removal should be performed at the earliest 1 1/2 years later or after radiographic verification of the healed bone. The problem of cold welding was resolved by using a special surface treatment (for further information see page 13).

 Open the catalog to page 11
PHLs-13

o Locking Locking works because: ♦ Screw material (TiALV) is slightly harder than plate material (Titanium Grade 2) • Screw head forms thread into the plate (no cutting) Benefits: • ± 15° and Locking • No pre threading • No cold welding • No debris • You can re-set the screw up to 3 times Dotize Type II anodization • Layer thickness 60-200nm Different colors + Film becomes an interstitial part of the titanium Implant surface remains sensitive to: Chipping - No visible cosmetic effect Peeling Discoloration Anodization Type II leads to following benefits* • Oxygen and silicon absorbing...

 Open the catalog to page 13
PHLs-14

Order list Humeral Head Plate, Small, 3-hole Humeral Head Plate, Small, 4-hole Cancellous Screw, locking, D=4.2mm, L=38mm, SH Cancellous Screw, locking, D=4.2mm, L=40mm, SH Cancellous Screw, locking, D=4.2mm, L=42mm, SH Cancellous Screw, locking, D=4.2mm, L=44mm, SH Cancellous Screw, locking, D=4.2mm, L=46mm, SH Cancellous Screw, locking, D=4.2mm, L=48mm, SH Cancellous Screw, locking, D=4.2mm, L=50mm, SH Cancellous Screw, locking, D=4.2mm, L=55mm, SH Cancellous Screw, locking, D=4.2mm, L=60mm, SH Cortical Screw, locking, D=3.5mm, L=24mm, SH Cortical Screw, locking, D=3.5mm, L=28mm, SH Cortical...

 Open the catalog to page 14
PHLs-16

The information below should help you in reconditioning medical devices. IMPORTANT INDICATIONS FOR DOCTORS & OPERATING THEATRE PERSONNEL This instruction Leaflet refers to all supplied non-steriLe implants and all reusable instruments from I.T.S. GmbH. Detailed information for the identification of the product (such as system classification, cat. no.) can be found in the product identification code and/ or on the packaging label. Make sure that you are familiar with the possible application, combinability and correct handling of the product. Please note that product systems can undergo modifications...

 Open the catalog to page 16
PHLs-17

Sterilisation with steam: Fractionated vacuum procedure (at least 3 pre-vacuum phases) Manual disinfection If a cleaning agent without a disinfectant effect is used, separate disinfection must be carried out after manual cleaning. (Order: Decontamination for staff protection, cleaning, disinfection). Equipment: Commercially available disinfectant authorised for use with medical products from the VAH list. Manufacturer's information, e.g. concerning concentration, temperature and exposure time should be followed. The steps described in the table above also apply. Drying See table above. Checking,...

 Open the catalog to page 17

All I.T.S. catalogs and technical brochures

  1. ufs

    1  Page

  2. DHL

    2  Pages

  3. ITS

    2  Pages

  4. SCL

    32  Pages

  5. SLS

    24  Pages

  6. PHL

    24  Pages

  7. CLS

    28  Pages

  8. ACLS

    20  Pages

  9. CFN

    32  Pages

  10. OLS

    24  Pages

  11. SR Sacral Rods

    20  Pages

  12. HCS

    24  Pages

  13. TLS

    20  Pages

  14. PRS-RX

    32  Pages

  15. HLS

    20  Pages

  16. ES

    20  Pages

  17. SR

    20  Pages

  18. FL

    24  Pages

  19. FLS

    24  Pages

  20. PFL

    20  Pages

  21. DTL

    24  Pages

  22. HTO

    24  Pages

  23. PTL

    32  Pages

  24. DFL

    32  Pages

  25. CAS

    40  Pages

  26. FCN

    20  Pages

  27. HOL

    24  Pages

  28. CAL

    20  Pages

  29. DUL

    24  Pages

Archived catalogs

  1. CS

    16  Pages

  2. OL

    16  Pages

  3. OHL

    24  Pages

  4. SL

    16  Pages

  5. SR Old

    20  Pages

  6. ES Old

    20  Pages

  7. CAS Old

    36  Pages

  8. SN Old

    16  Pages

  9. FCN Old

    16  Pages

  10. FTN

    12  Pages

  11. CLS

    24  Pages

  12. DFL Old

    28  Pages

  13. PRS

    28  Pages

  14. PHL

    16  Pages

  15. DHL

    16  Pages

  16. PRL

    28  Pages

  17. UOL

    32  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.