PRL

Product catalog summary
Introduction
The PROlock Radius Locking Plate 2.0 is a medical implant designed for treating distal radius fractures, offering improved features for reduced tendon irritation and precise screw placement.

Properties
Made from titanium with TiAl6V4 ELI screws, the implant provides enhanced fatigue strength and reduced inflammation risk. It features multidirectional locking, an anatomical design, and K-wire holes for fixation. The plate is pre-contoured but allows slight adjustments.

Indications & Contraindications
Suitable for complex intra-articular and extra-articular distal radius fractures and corrective osteotomy. Not recommended for advanced osteoporosis or severe joint surface disintegration.

Surgical Technique
Involves a volar incision with fracture reduction and implant securing using screws, guided by fluoroscopy.

Postoperative Treatment
Includes a dorsal splint for 1-2 weeks and physiotherapy.

Explantation
Possible after 6 months, with surface treatments reducing cold welding risk.

Summary
The implant provides effective stabilization, facilitating rapid rehabilitation and early wrist movement.

Order Information
Available in various sizes with specific product codes.

Locking Mechanism
Allows multiple screw adjustments without pre-threading or cold welding.

Dotize® Technology
Anodization process enhances surface, reducing inflammation risk and improving wear resistance.

Sterilization Guidelines
Implants are non-sterile and require steam sterilization before use, with specific handling precautions.

Cleaning, Disinfection, and Drying Procedures
  • Automatic Cleaning: Use a disinfector with a pH less than 11, dismantling instruments for effective cleaning.
  • Manual Cleaning: Use a cleaning agent with a pH less than 11 and nylon brushes, ensuring thorough rinsing.
  • Disinfection: Use authorized disinfectants with a final rinse at 90°C for thermal disinfection.
  • Drying: Should not exceed 110°C.
Inspection and Maintenance
Inspect for dirt, lubricate mechanisms, and ensure proper assembly.

Sterilization
Hospitals are responsible for assembly and sterilization, following manufacturer's guidelines.

Disposal and Patient Information
Follow hospital guidelines for disposal and inform patients about post-implantation care.

Responsibility and Important Notes
Ensure instruments are cleaned, disinfected, and sterilized before returning to I.T.S. GmbH.

Symbols and Contact Information
Includes compliance symbols and contact details for I.T.S. GmbH.
See more

Catalog excerpts

PRL-1

PRL PROlock RADIUS LOCKING PLATE 2.0 emergency team for broken bones®

 Open the catalog to page 1
PRL-2

CONTENT Introduction 3 Properties 4 Indication & Contraindication 8 Time of Operation Surgical Technique Preface 8 Positioning of the Patient 9 Access Implantation 10 Postoperative Treatment 18 Explantation 18 Summary Information 10 18 Order Information 20 Locking 22 Dotize® 23 Sterilization Guidelines 24 Notes 26

 Open the catalog to page 2
PRL-3

Preface Preface: The development of the PROlock Radius Locking Plate 2.0 is based on the excellent results of the previous I.T.S. Radius Plates. Minimisation of the flexor tendon irritation due to anatomical plate design and rounded edges. Precise and rapid screw placement of the distal plate holes with predefined angles due to radiolucent drill guide. The special feature of this implant is the free choice of screw placement. So the user is able to set every desired screw in every hole (except long hole). 03

 Open the catalog to page 3
PRL-4

PROlock Radius Locking Plate 2.0 32271-XX Cortical Screw, D=2.7mm 61203-100 Spiral Drill, D=2.0mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37304-XX Cortical Stabilization Screw RH, D=3.0mm 61243-100 Spiral Drill, D=2.4mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37303-XX Cancellous Stabilization Screw RH, D=3.0mm 61203-100 Spiral Drill, D=2.0mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 37241-XX Stabilization Screw RH, D=2.4mm 61183-100 Spiral Drill, D=1.8mm, L=100mm, AO Connector 56095-70 Screwdriver, Torque, T9x70 35164-150 Guide Wire, Steel,...

 Open the catalog to page 4
PRL-5

• Multidirectional Locking • Version left/right • Minimisation of the flexor tendon irritation due to anatomical plate design • K-Wire holes for preliminary plate fixation • Long hole for optimal positioning and adjustment of radius length • Optionally drill block • Plate material: Titanium • Easier removal after fracture has healed • Improved fatigue strength of Implant • Reduced risk of cold bonding • Reduced risk of Inflammation and allergy All ITS locking plates are anatomically pre-ccrtcurco. n- the unlikely oven: tra: :rc- cla:c "as to be formed to the bone please no:;cc :nat slight contouring...

 Open the catalog to page 5
PRL-6

Advanced Properties PROlock 2.0: • Predefined angles of the distal holes 4 Version left 3 5 6 2 7 1 1 Version right 7 2 3 4 6 5 Hole number 1 2 3 4 5 6 7 06 Proximal/distal direction distal 15° proximal 5° proximal 5° proximal 5° distal 5° distal 5° distal 10° Ulnar/radial direction radial 8° radial 8° radial 3° ulnar 3° 0° radial 7° radial 13°

 Open the catalog to page 6
PRL-7

Drill Block Properties Left Right • Precise and rapid screw placement with predefined angles • Click mechanism for easy mounting and disassembly • Radiolucent • Allows for screw insertion through drill block • Color coding for left and right version Assembling • Slide the drill block to the distal end till it engages audible into the designated holes (see picture on the right, red marked) • In addition there is the possibility to fix the drill block with a K-Wire (see picture on the right, blue marked) • Depth gauge, PROlock II in single-hand design (59026) can be pushed through the drill block...

 Open the catalog to page 7
PRL-8

Indication & Contraindication Indication: • Complex intra-articular fractures of the distal radius with comminuted zone • Complex extra-articular fractures of the distal radius with comminuted zone • Corrective osteotomy of the distal radius Contraindication: • Very advanced osteoporosis with soft bones • Disintegration of the radius-joint surfaces to the extent that there is no support for screws Time of Operation Time of Operation: • Acut, on the day of the accident • After swelling has subsided (5-10 days) In the case of additional questions concerning the wrist surface, a CT scan can be performed....

 Open the catalog to page 8
PRL-9

Positioning of the Patient Positioning of the Patient: • The patient is placed in the supine position with pneumatic partial deprivation of blood supply • The hand is positioned on a X-ray transparent surgical hand table 09

 Open the catalog to page 9
PRL-10

Access The skin incision is performed volarly on the distal forearm above the tendon of the flexor carpi radialis and reaching to the crease of the wrist (FCR-approach). Splitting of the deep fascia of the forearm, releasing the pronator quadratus muscle from the distal radius beginning at the radial edge. Implantation Suspending the thumb with a counterpoise, the fracture is loosened and the length restored. The individual fragments are positioned using the raspatory, and, if necessary, the comminuted zones are filled with bone substitute to achieve a provisional reduction in position and length....

 Open the catalog to page 10
PRL-11

Possible temporary fixation of individual fragments using guide wire, steel, D=1.6mm, L=150mm, TR w. Thrd. (35164-150) - check reduction using the fluoroscope. After anatomical reduction is achieved, the implant is chosen and, if required, its shape can be additionally adapted. First, fill the long hole with a D=2.7mm cortical screw (32271-XX) (suitable drills see page 4). Once more check the reduction and position of the plate using the fluoroscope. 11

 Open the catalog to page 11
PRL-12

Due to the longhole it is possible to adjust the plate position either distal or proximal. 12

 Open the catalog to page 12
PRL-13

For temporary fixation of the fragments there are 3 distal K-wire holes. 13

 Open the catalog to page 13
PRL-14

Following fill the shaft holes optionally with D=3.0mm cortical stabilization screws (37304-XX) or with D=2.7mm cortical screws (32271-XX) (suitable drills see page 4). 14

 Open the catalog to page 14
PRL-15

After re-checking the reduction 4 or more D=2.4mm stabilization screws (37241-XX) or D=3.0mm cancellous stabilization screws (37303-XX) should be used for the relevant fragments (suitable drills see page 4). Pay attention that the distal locking screws are placed as closely to the wrist surface as possible in order to take advantage of the hard subchondral bone. Two rows of screws are recommended to provide optimal support to the articular surface especially if only the D=2.4mm stabilization screw is used. Final checking using the fluoroscope. 15

 Open the catalog to page 15

All I.T.S. catalogs and technical brochures

  1. ufs

    1  Page

  2. DHL

    2  Pages

  3. ITS

    2  Pages

  4. SCL

    32  Pages

  5. SLS

    24  Pages

  6. PHL

    24  Pages

  7. PHLs

    20  Pages

  8. CLS

    28  Pages

  9. ACLS

    20  Pages

  10. CFN

    32  Pages

  11. OLS

    24  Pages

  12. SR Sacral Rods

    20  Pages

  13. HCS

    24  Pages

  14. TLS

    20  Pages

  15. PRS-RX

    32  Pages

  16. HLS

    20  Pages

  17. ES

    20  Pages

  18. SR

    20  Pages

  19. FL

    24  Pages

  20. FLS

    24  Pages

  21. PFL

    20  Pages

  22. DTL

    24  Pages

  23. HTO

    24  Pages

  24. PTL

    32  Pages

  25. DFL

    32  Pages

  26. CAS

    40  Pages

  27. FCN

    20  Pages

  28. HOL

    24  Pages

  29. CAL

    20  Pages

  30. DUL

    24  Pages

Archived catalogs

  1. CS

    16  Pages

  2. OL

    16  Pages

  3. OHL

    24  Pages

  4. SL

    16  Pages

  5. SR Old

    20  Pages

  6. ES Old

    20  Pages

  7. CAS Old

    36  Pages

  8. SN Old

    16  Pages

  9. FCN Old

    16  Pages

  10. FTN

    12  Pages

  11. CLS

    24  Pages

  12. DFL Old

    28  Pages

  13. PRS

    28  Pages

  14. PHL

    16  Pages

  15. DHL

    16  Pages

  16. UOL

    32  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.