SCL - 1

Implants trauma Straight Compression Locking Plate

Open the catalog to page 1
SCL - 2

CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or...

Open the catalog to page 2
SCL - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Drill Guide P. 10 Implantation P. 11 Compression 0 - 3.5mm P. 17 Compression 0 - 7mm P. 25 Postoperative treatment P. 25 Explantation P. 25 Summary 3. Information P. 27 Locking P. 27 Dotize® P. 28 Order list P. 29 Notes P. 30 Reconditioning Manual

Open the catalog to page 3
SCL - 5

Preface The special feature of this implant is its compression hole. Due to an innovative technology it is possible to compress a fracture gap up to 7mm. A special design of the compression hole enables the use of a locking screw, which locks automatically after the full distance of compression. Indentations on the rear side of the plate for protection of the periosteum.

Open the catalog to page 5
SCL - 6

37351-XX-N-N Cortical Screw, Locking, D=3.5mm, SH 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 35164-150 Guide wire, steel, D=l.6mm,

Open the catalog to page 6
SCL - 7

Properties Properties of the implant: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Indentations on the rear side of the plate for protection of the periosteum • Anatomical plate design • K-Wire holes for preliminary plate fixation • Fracture gap compression up to 7mm • Plate lengths: 4, 6, 8, 10-hole

Open the catalog to page 7
SCL - 8

Indications, Contraindications & Time of operation Indications: • The plate should primary be used to reconstruct an anatomic situation • Corrective osteotomies The plate is not intended for shaft fractures of large bones such as femur and tibia Advanced osteoporosis In cases of skin and soft tissue problems Obesity Lack of patient compliance Time of operation: • Whitin the first hours after trauma • After swelling decreases (5-10 days)

Open the catalog to page 8
SCL - 9

Surgical Technique

Open the catalog to page 9
SCL - 10

Drill Guide Properties: • Two drill holes for free choice of using compression or static fixation • Special design of drill guide enables centric placement in the plate hole Hole close to handle for drilling a fixation screw Dark grey marked hole for drilling a compression screw Asymmetric centering assistance for easy placement in the plate hole Implantation • Prepare the patient with a general or regional anesthetic to the affected limb and use a pneumatic (tourniquet) for partial deprivation of the blood supply. • During the procedure, observe (using intra-operative x-ray fluoroscopy)...

Open the catalog to page 10
SCL - 11

Compression 0 - 3.5mm For the compression up to 3.5mm alternatively the D=3.5mm cortical screw and the D=3.5mm locking cortical screw can be used at one side of the fracture to fixate the plate on the bone. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed.

Open the catalog to page 11
SCL - 12

Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide, D=2.7mm (62216) in the plate hole near the fracture. In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed.

Open the catalog to page 12
SCL - 13

On the right side of the fracture the D=3.5mm cortical screw and the D=3.5mm locking cortical screw are placed for the compression. Attach the drill guide (62216) in the opposite plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed half way down as it is used as a guide screw during the compression.

Open the catalog to page 13
SCL - 14

Attach the drill guide (62216) in the adjacent plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down.

Open the catalog to page 14
SCL - 15

During screwing in the D=3.5mm locking cortical screw (37351-XX-N) a compression is exerted to the fracture gap (see pictures below).

Open the catalog to page 15
SCL - 16

Afterwards attach the drill guide, D=2.7mm (62216) to the furthest left plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed. Attach the drill guide, D=2.7mm (62216) to the furthest right plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is...

Open the catalog to page 16
SCL - 17

Compression 0 - 7mm For the compression up to 7mm the D=3.5mm locking cortical screws are used at both sides of the fracture for compression. The D=3.5mm cortical screws and the D=3.5mm locking cortical screws in both plate holes farthest to the fracture are for fixation. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down (screw head may not have...

Open the catalog to page 17

All I.T.S. catalogs and technical brochures

  1. ufs

    1 Pages

  2. DHL

    2 Pages

  3. ITS

    2 Pages

  4. PHL

    24 Pages

  5. ACLS

    20 Pages

  6. CFN

    32 Pages

  7. OLS

    24 Pages

  8. PHLs

    20 Pages

  9. SR Sacral Rods

    20 Pages

  10. HCS

    24 Pages

  11. TLS

    20 Pages

  12. PRS-RX

    32 Pages

  13. HLS

    20 Pages

  14. ES

    20 Pages

  15. SR

    20 Pages

  16. FL

    24 Pages

  17. CAS

    40 Pages

  18. FCN

    20 Pages

  19. HOL

    24 Pages

  20. FLS

    24 Pages

  21. PFL

    20 Pages

  22. DTL

    24 Pages

  23. HTO

    24 Pages

  24. PTL

    32 Pages

  25. DFL

    32 Pages

  26. SLS

    24 Pages

  27. CAL

    20 Pages

  28. DUL

    24 Pages

  29. CLS

    28 Pages

Archived catalogs

  1. SR Old

    20 Pages

  2. ES Old

    20 Pages

  3. CAS Old

    36 Pages

  4. CS

    16 Pages

  5. SN Old

    16 Pages

  6. FCN Old

    16 Pages

  7. DFL Old

    28 Pages

  8. FTN

    12 Pages

  9. PRS

    28 Pages

  10. PRL

    28 Pages

  11. UOL

    32 Pages

  12. SL

    16 Pages

  13. OHL

    24 Pages

  14. OL

    16 Pages

  15. DHL

    16 Pages

  16. PHL

    16 Pages

  17. CLS

    24 Pages