  • Preface: The implant includes a compression hole for fracture gap compression up to 7mm, using a locking screw that secures automatically after full compression.
  • Screws: Lists various screws and tools, including cortical screws and spiral drills.
  • Properties: Made of titanium, the implant offers enhanced fatigue strength and reduced inflammation risk, featuring multi-directional locking and anatomical design.
  • Indications & Contraindications: Suitable for anatomical reconstructions and corrective osteotomies, but not for large bone shaft fractures or patients with advanced osteoporosis.
Surgical Technique
  • Drill Guide: Includes two drill holes for compression or static fixation.
  • Implantation: Covers patient preparation, incision, and fracture alignment using forceps.
  • Compression: Details steps for achieving compression up to 3.5mm and 7mm with specific screws and drill guides.
  • Postoperative Treatment: Involves bandage dressing, physical therapy, and guidelines for full weight-bearing.
  • Explantation: Implant removal is possible 6 months to 1.5 years post-operation.
Information
  • Dotize®: An anodization process that enhances implant surface properties, reducing inflammation risk and improving fatigue resistance.
  • Locking Mechanism: Uses a screw material harder than the plate for secure locking without pre-threading.
Reconditioning Manual
  • Guidelines for handling and reconditioning non-sterile implants and reusable instruments, emphasizing careful handling and regular follow-up examinations.
Specifications and Recommendations
Soft nylon brushes are recommended for cleaning to avoid surface damage. Steam sterilization is advised for medical products from I.T.S. GmbH. Contaminants should not be allowed to dry to ease cleaning and sterilization.

Restrictions
Repeated preparation of reusable instruments has minimal effects if procedures are followed. Product service life is determined by wear and damage. Aluminium instruments can be damaged by alkaline cleaning agents.

Instructions for Recycling Reusable Instruments
Preparation at the Location of Use: Remove surface dirt with a disposable cloth. Rinse hollow parts with saline solution if reconditioning is immediate.
Storage and Transport: No special requirements, but reconditioning should be done promptly.

Cleaning/Disinfection/Drying
Automatic Cleaning/Disinfection: Use a washer-disinfector conforming to EN ISO 15883. Recommended equipment includes Miele PG 8536 machine and Neodisher® Mediclean forte. Follow validated steps for cleaning and thermal disinfection.
Manual Cleaning/Disinfection: Avoid manual procedures unless necessary. Use authorized cleaning agents and soft nylon brushes. Follow manufacturer’s instructions for concentration and exposure time.

Checking, Maintenance, and Inspection
Inspect instruments for dirt and ensure movable parts function correctly. Use authorized lubricants for movable mechanisms.

Packaging and Sterilization
Packaging is for transport only and not suitable for sterilization. Sterilize using fractionated pre-vacuum procedure as per EN 285 and EN ISO 17665. Recommended steam sterilization parameters are 134°C for 5 to 18 minutes.

Disposal and Responsibility
Hospital guidelines apply for disposal. Instruments returned to I.T.S. GmbH must be cleaned, disinfected, and sterilized.

Important Information
Instructions are validated for reconditioning. Reconditioners must ensure processes achieve desired results through validation and routine inspections.

Patient Information
Patients should be informed about post-implantation behavior and the importance of reporting any negative changes.

Symbols and Contact Information
Various symbols indicate product specifications such as single use, sterilization methods, and material used. Contact I.T.S. USA for further information.
See more

Catalog excerpts

SCL-1

Implants trauma Straight Compression Locking Plate

 Open the catalog to page 1
SCL-2

CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a board certified physician. WARNING: If there is no sufficient bone healing, wrong or incomplete postoperative care, plate might break. All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent...

 Open the catalog to page 2
SCL-3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 8 Indications & Contraindications P. 8 Time of operation 2. Surgical Technique P. 10 Drill Guide P. 10 Implantation P. 11 Compression 0 - 3.5mm P. 17 Compression 0 - 7mm P. 25 Postoperative treatment P. 25 Explantation P. 25 Summary 3. Information P. 27 Locking P. 27 Dotize® P. 28 Order list P. 29 Notes P. 30 Reconditioning Manual

 Open the catalog to page 3
SCL-5

Preface The special feature of this implant is its compression hole. Due to an innovative technology it is possible to compress a fracture gap up to 7mm. A special design of the compression hole enables the use of a locking screw, which locks automatically after the full distance of compression. Indentations on the rear side of the plate for protection of the periosteum.

 Open the catalog to page 5
SCL-6

37351-XX-N-N Cortical Screw, Locking, D=3.5mm, SH 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 61273-100 Spiral Drill, D=2.7mm, L=l00mm, AO Connector self-holding sleeve 35164-150 Guide wire, steel, D=l.6mm,

 Open the catalog to page 6
SCL-7

Properties Properties of the implant: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Multi-directional locking • Indentations on the rear side of the plate for protection of the periosteum • Anatomical plate design • K-Wire holes for preliminary plate fixation • Fracture gap compression up to 7mm • Plate lengths: 4, 6, 8, 10-hole

 Open the catalog to page 7
SCL-8

Indications, Contraindications & Time of operation Indications: • The plate should primary be used to reconstruct an anatomic situation • Corrective osteotomies The plate is not intended for shaft fractures of large bones such as femur and tibia Advanced osteoporosis In cases of skin and soft tissue problems Obesity Lack of patient compliance Time of operation: • Whitin the first hours after trauma • After swelling decreases (5-10 days)

 Open the catalog to page 8
SCL-9

Surgical Technique

 Open the catalog to page 9
SCL-10

Drill Guide Properties: • Two drill holes for free choice of using compression or static fixation • Special design of drill guide enables centric placement in the plate hole Hole close to handle for drilling a fixation screw Dark grey marked hole for drilling a compression screw Asymmetric centering assistance for easy placement in the plate hole Implantation • Prepare the patient with a general or regional anesthetic to the affected limb and use a pneumatic (tourniquet) for partial deprivation of the blood supply. • During the procedure, observe (using intra-operative x-ray fluoroscopy) the...

 Open the catalog to page 10
SCL-11

Compression 0 - 3.5mm For the compression up to 3.5mm alternatively the D=3.5mm cortical screw and the D=3.5mm locking cortical screw can be used at one side of the fracture to fixate the plate on the bone. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed.

 Open the catalog to page 11
SCL-12

Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide, D=2.7mm (62216) in the plate hole near the fracture. In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed.

 Open the catalog to page 12
SCL-13

On the right side of the fracture the D=3.5mm cortical screw and the D=3.5mm locking cortical screw are placed for the compression. Attach the drill guide (62216) in the opposite plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm cortical screw (32351-XX) is placed half way down as it is used as a guide screw during the compression.

 Open the catalog to page 13
SCL-14

Attach the drill guide (62216) in the adjacent plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide, D=2.7mm (62216). In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down.

 Open the catalog to page 14
SCL-15

During screwing in the D=3.5mm locking cortical screw (37351-XX-N) a compression is exerted to the fracture gap (see pictures below).

 Open the catalog to page 15
SCL-16

Afterwards attach the drill guide, D=2.7mm (62216) to the furthest left plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed. Attach the drill guide, D=2.7mm (62216) to the furthest right plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the hole close to handle of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed....

 Open the catalog to page 16
SCL-17

Compression 0 - 7mm For the compression up to 7mm the D=3.5mm locking cortical screws are used at both sides of the fracture for compression. The D=3.5mm cortical screws and the D=3.5mm locking cortical screws in both plate holes farthest to the fracture are for fixation. Attach the drill guide, D=2.7mm (62216) in any plate hole. Use the spiral drill, D=2.7mm, L=100mm, AO Connector (61273-100) to drill through the dark gray marked hole of the drill guide. In accordance with the measured length a D=3.5mm locking cortical screw (37351-XX-N) is placed half way down (screw head may not have contact...

 Open the catalog to page 17

All I.T.S. catalogs and technical brochures

  1. ufs

    1  Page

  2. DHL

    2  Pages

  3. ITS

    2  Pages

  4. SLS

    24  Pages

  5. PHL

    24  Pages

  6. PHLs

    20  Pages

  7. CLS

    28  Pages

  8. ACLS

    20  Pages

  9. CFN

    32  Pages

  10. OLS

    24  Pages

  11. SR Sacral Rods

    20  Pages

  12. HCS

    24  Pages

  13. TLS

    20  Pages

  14. PRS-RX

    32  Pages

  15. HLS

    20  Pages

  16. ES

    20  Pages

  17. SR

    20  Pages

  18. FL

    24  Pages

  19. FLS

    24  Pages

  20. PFL

    20  Pages

  21. DTL

    24  Pages

  22. HTO

    24  Pages

  23. PTL

    32  Pages

  24. DFL

    32  Pages

  25. CAS

    40  Pages

  26. FCN

    20  Pages

  27. HOL

    24  Pages

  28. CAL

    20  Pages

  29. DUL

    24  Pages

Archived catalogs

  1. CS

    16  Pages

  2. OL

    16  Pages

  3. OHL

    24  Pages

  4. SL

    16  Pages

  5. SR Old

    20  Pages

  6. ES Old

    20  Pages

  7. CAS Old

    36  Pages

  8. SN Old

    16  Pages

  9. FCN Old

    16  Pages

  10. FTN

    12  Pages

  11. CLS

    24  Pages

  12. DFL Old

    28  Pages

  13. PRS

    28  Pages

  14. PHL

    16  Pages

  15. DHL

    16  Pages

  16. PRL

    28  Pages

  17. UOL

    32  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.