STRAIGHT LOCKING PLATE 2.0mm emergency team for broken bones®
Open the catalog to page 1
multidirectional locking free choice of screw angle accurate fitting of the plate on the bone STRAIGHT PLATE emergency team for broken bones® 37351-XX-N Cortical Screw, locking, D=3.5mm, SH 61273-100 Spiral Drill, D=2.7mm, L=100mm, AO Connector 56252 Screwdriver, WS 2.5, self-holding sleeve 32351-XX Cortical Screw, D=3.5mm 61273-100 Spiral Drill, D=2.7mm, L=100mm, AO Connector 56252 Screwdriver, WS 2.5, self-holding sleeve 02 i.t.s.
Open the catalog to page 2
Features Features Implant: Material: • ultidirectional Locking M • ccurate fitting of the plate on A the bone • ree choice of screw angle F • natomically contoured A • late lengths: P 4, 5, 6, 7, 8, 9, 11, 13- holes • 3.5 mm Cortical Screw Ø • 3.5 mm locking Cortical Screw Ø • late material: Titanium P • aterial of screws: TiAL6V4 ELI M • asier removal of implant after fracture has E healed • mproved fatigue strength of implant I • educed risk of cold bonding R • educed risk of inflammation and allergy R locking STRAIGHT PLATE All I.T.S. locking plates are anatomically pre-contoured. In the...
Open the catalog to page 3
Indications Contraindications • he plate should primary be T used to reconstruct a anatomic situation. • orrective osteotomies C • he plate is not to be intended T for shaft fractures of large bones such as humerus, femur and tibia • dvanced osteoporosis A • In cases of skin and soft tissue problems • Lack of patient compliance STRAIGHT PLATE emergency team for broken bones® Surgical Technique 1. Prepare the patient with a general or regional anesthetic to the affected limb and use a pneumatic (tourniquet) for partial deprivation of the blood supply. locking Straight Plate 04 i.t.s. locking...
Open the catalog to page 4
3. Make the proper incision to the limb subchondral bone fracture site. Proceed with transection of musculature if possible along the course of muscle fibers. Reduce and align fracture segments using bone holding forceps. 4. Place the appropriate size bone plate across the fracture site. 5. Using the drill guide and drill instruments, drill the appropriate size hole (2.7 mm hole for the 3.5 mm Cortical Screw) at up to a ±15° angulation through each plate hole for maximum position and purchase in the near and opposite cortex of the limb subchondral bone. 6. Using the screw Depth Gauge...
Open the catalog to page 5
Implants & Instruments STRAIGHT PLATE emergency team for broken bones® Order No. 11 12 Spiral Drill, D=2.7mm, L=100mm, AO Connector 13 Cortical Counter Sink, with Stop Support 63404 14 Depth Gauge, Solid Small Fragment Screws 59022 15 Drill Guide, D=2.0/2.7mm 62202 16 08 i.t.s. Screw Driver, WS 2.5, Self Holding Sleeve 56252 Sterilization Tray, Straight Plate 50166 61273-100
Open the catalog to page 8
LOCKING Locking works because of: • Screw material (TiAlV) is slightly harder than plate material (Titanium Grade 2) • Screw head forms thread into the plate (no cutting) Benefits: • • • • • ± 15° and Locking No pre threading No cold welding No debris Re-setting of screw (up to 3 times) 30° ® DOTIZE Chemical process - anodization in a strong alkaline solution * Type III anodization Dotize Type II anodization Layer thickness 60-200nm Layer thickness 2000-10 000nm + Different colors + Film become an interstitial part of the titanium - Implant surface remains sensitive to: Chipping Peeling...
Open the catalog to page 10
Sterilization Guidelines The following remarks should serve as a guideline in the sterilization of medical products. IMPORTANT INDICATIONS FOR DOCTORS AND OPERATING THEATRE PERSONNEL This instruction leaflet refers to all supplied nonsterile implants and all reusable instruments from I.T.S. GmbH. Detailed information for the identification of the product (such as system classification, cat. no.) can be found in the product identification code and/ or on the package label. Make sure that you are familiar with the possibilities of application, combinability and correct handling of the...
Open the catalog to page 12
Sterilization Guidelines Disinfection Equipment: Commercially available disinfectants authorized for use with medical products e.g.. MEDICLEAN FORTE) can be used (but only according to the instructions of the disinfectant producer). In the case of automatic cleaning, a final rinse cycle at 90 °C for 5 minutes can be finally carried out to provide thermal disinfection. Drying Drying as part of the cleaning/ disinfection cycle should not exceed 110 °C. Checking, Maintenance and Inspection • Each instrument or implant is to be inspected carefully to make sure that all visible dirt has been...
Open the catalog to page 13
part of the MED-HOLD GROUP misprints excepted.,
Open the catalog to page 16All I.T.S. catalogs and technical brochures
-
ufs
1 Pages
-
DHL
2 Pages
-
ITS
2 Pages
-
PHL
24 Pages
-
ACLS
20 Pages
-
CFN
32 Pages
-
OLS
24 Pages
-
PHLs
20 Pages
-
CTN - Cannulated Tibia Nail
28 Pages
-
SR Sacral Rods
20 Pages
-
HCS
24 Pages
-
TOS Twist-Off Screw
20 Pages
-
TLS
20 Pages
-
PRS-RX
32 Pages
-
HLS
20 Pages
-
ES
20 Pages
-
SR
20 Pages
-
FL
24 Pages
-
PL - Pilon Locking Plate small
12 Pages
-
OL - Olecranon Locking Plate
24 Pages
-
CAS
40 Pages
-
FCN
20 Pages
-
HOL
24 Pages
-
FLS
24 Pages
-
PFL
20 Pages
-
DTL
24 Pages
-
HTO
24 Pages
-
PTL
32 Pages
-
DFL
32 Pages
-
SCL
32 Pages
-
SLS
24 Pages
-
CAL
20 Pages
-
DUL
24 Pages
-
CLS
28 Pages