architect

architect

architect

Product catalog summary
Overview: The document provides detailed information about the Architect CoCr Coronary Stent, highlighting its design, performance, and specifications. It emphasizes the stent's deliverability, radial strength, and adaptability to vascular anatomy.
Specifications:
  • Material: Cobalt Chromium L605
  • Design: Open Cell with 13% covered surface
  • Wall Thickness: From 70 microns
  • Shortening: Less than 3%
  • Recoil: Less than 4%
  • Radiopaque Marks: PtIr
Performance:
  • Deliverability: Excellent, based on the Xperience platform with smooth force transition for optimal pushability and distal flexibility.
  • Radial Strength: Extraordinary, with excellent flexibility, allowing for deliverability in tortuous vessels.
  • Recoil: Lowest compared to competitors like Omega, Boston, Multilink 8, and Integrity.
  • Conformability: Superior adaptation to vessel walls, especially in 3.5 mm diameter stents.
Delivery System Features:
  • Nominal Pressure: 12 atm
  • Rated Burst Pressure: 16 atm
  • Average Burst Pressure: 22 atm
  • Rapid Exchange (RX) System
  • Usable Catheter Length: 142 cm
  • Guidewire Compatibility: Max 0.014”
  • Guide Catheter Sheath Compatibility: 5F for 2.0-3.5 mm stents, 6F for 4.0-4.5 mm stents
  • Tip Profile: 0.017”
Product Range: The stents are available in various diameters (2.00 mm to 4.50 mm) and lengths (9 mm to 39 mm), with specific references for each size.
Certification: The product is CE Mark certified, ensuring compliance with European health, safety, and environmental protection standards.
Manufacturer Information: The stent is manufactured by LVD Biotech, S.L., located in Barcelona, Spain.
See more

Catalog excerpts

architect-1

CoCr Coronary stent

 Open the catalog to page 1
architect-2

Outstanding deliverability Excellent deliverability performance based on Xperience platform. Accurate distal control thanks to its smooth force transition optimizing pushability with outstanding distal flexibility. Stent strut with balance wideness to optimize the radial strength and flexibility allowing deliverability even in very tortuous vessels. architect - CoCr Coronary stent

 Open the catalog to page 2
architect-3

Extraordinary scaffolding Recoil (%) The lowest recoil compared to the best in class. Integrity Medtronic Multilink 8 Abbott 4.10% Superior conformability to vessel walls The expanded stent adapts superbly to the vascular anatomy. 2.50% 2.00% Results based on 3.5 mm diameter stents. Radial strength (N/mm) Extraordinary radial strength with excellent flexibility. Integrity Omega Boston Superb re-crossing side-branches 0.400 0.300 0.200 0.100 0.000 Radial strength on 3.5 mm diameter stents. Test performed by iVascular. Data on file at iVascular. architect - CoCr Coronary stent

 Open the catalog to page 3
architect-4

General features Delivery system features • Stent material: Cobalt Chromium L605 • Design details: Open Cell • Rated burst pressure: 16 atm • Average burst pressure: 22 atm • Wall thickness: from 70 micron • Usable Catheter length: 142 cm • Radiopaque marks: PtIr • Guide catheter sheath compatibility: 5F compatibility for stents from 2.0 mm to 3.5 mm diameters and 6F for stents from 4.0 to 4.5 mm diameters • Tip profile: 0,017” CE Mark certified product References Usable catheter length: 142 cm (total length: 150 cm) Stent iameter (mm) d ® therapies for living Distributed by LVD Biotech, S.L....

 Open the catalog to page 4